• Title/Summary/Keyword: Image compare method

Search Result 629, Processing Time 0.03 seconds

Quantification of Experimentally Induced-Pleural Effusion in Beagle Dogs: Radiography versus CT and Ultrasonography (비글견에서 실험적으로 유발한 흉수의 정량 평가: 방사선, 컴퓨터단층촬영 및 초음파 검사 비교)

  • Lee, Ki-Ja;O, I-Se;Jeong, Seong-Mok;Lee, Hee-Chun;Park, Seong-Jun;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.25 no.2
    • /
    • pp.96-101
    • /
    • 2008
  • This study was performed to quantify the pleural effusion in radiography, ultrasonography and computed tomography(CT) and to evaluate and compare the usefulness of these methods. Normal saline of 10 ml/kg was infused into the pleural space until a final loading volume of 60 ml/kg body weight was reached in six Beagle dogs. The radiographic examination was performed for the detection and quantification of pleural effusion. On the ultrasonographic study, the maximum perpendicular distance was measured between the surface of the lung and the thoracic wall to evaluate pleural effusion. On the CT image, pleural effusion was evaluated as the perpendicular distance to the thoracic surface in the maximum pleural effusion volume on any transverse images with soft tissue window. Statistical analysis was performed using linear regression test. The volume of pleural effusion and measurements of radiography and ultrasonography had no statistical relationship. However, a significant correlation was identified between the volume of pleural effusion and the depth at right ($r^2=0.715$), left ($r^2=0.745$), and mean right and left depth ($r^2=0.844$) on the CT images. All of the thoracic radiographs, ultrasonography, and CT are useful in recognition of pleural effusion. In quantification of pleural effusion, the CT measurement method is superior to radiographic and ultrasonographic measurements.

Deinterlacing Method for improving Motion Estimator based on multi arithmetic Architecture (다중연산구조기반의 고밀도 성능향상을 위한 움직임추정의 디인터레이싱 방법)

  • Lee, Kang-Whan
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.1
    • /
    • pp.49-55
    • /
    • 2007
  • To improved the multi-resolution fast hierarchical motion estimation by using de-interlacing algorithm that is effective in term of both performance and VLSI implementation, is proposed so as to cover large search area field-based as well as frame based image processing in SoC design. In this paper, we have simulated a various picture mode M=2 or M=3. As a results, the proposed algorithm achieved the motion estimation performance PSNR compare with the full search block matching algorithm, the average performance degradation reached to -0.7dB, which did not affect on the subjective quality of reconstructed images at all. And acquiring the more desirable to adopt design SoC for the fast hierarchical motion estimation, we exploit foreground and background search algorithm (FBSA) base on the dual arithmetic processor element(DAPE). It is possible to estimate the large search area motion displacement using a half of number PE in general operation methods. And the proposed architecture of MHME improve the VLSI design hardware through the proposed FBSA structure with DAPE to remove the local memory. The proposed FBSA which use bit array processing in search area can improve structure as like multiple processor array unit(MPAU).

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

Exploring Preservice Science Teachers' Views of the Nature of Science: Biology vs. Non-Biology Teachers (예비 과학교사의 과학의 본성에 대한 인식 조사: 생물과 비생물 교사와의 비교)

  • Kim, Sun-Young
    • Journal of The Korean Association For Science Education
    • /
    • v.30 no.2
    • /
    • pp.206-217
    • /
    • 2010
  • This study aims to explore preservice teachers' overall views of nature of science and compare their views by gender and certificate area (biology vs. non-biology teachers). In addition, a comparison with American preservice teachers' views was also implemented. The Views of Nature of Science (Abd-El-Khalick, 1998), an openended questionnaire, is utilized to explore participants' views of nature of science. Along with 'definition of science', six aspects of the nature of science, (1) theories and laws, (2) tentativeness, (3) social and cultural embeddedness, (4) creativity, (5) theory-laden, and (6) inference, were investigated. The qualitative result indicates that the participants' first image of science was about the method of science such as observations and experiments. Furthermore, these preservice science teachers particularly have a difficulty in differentiating between scientific theories and laws, and understanding the importance of creation and imagination in developing scientific knowledge. In addition, compared to American preservice teachers' view of the nature of science, Korean preservice teachers possess naive views in creative and imaginative aspect. Interestingly, biology teachers demonstrated lower understanding in theories and laws as well as tentativeness of scientific knowledge. However, there is no difference by gender.

A Concordance Study of the Preprocessing Orders in Microarray Data (마이크로어레이 자료의 사전 처리 순서에 따른 검색의 일치도 분석)

  • Kim, Sang-Cheol;Lee, Jae-Hwi;Kim, Byung-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.3
    • /
    • pp.585-594
    • /
    • 2009
  • Researchers of microarray experiment transpose processed images of raw data to possible data of statistical analysis: it is preprocessing. Preprocessing of microarray has image filtering, imputation and normalization. There have been studied about several different methods of normalization and imputation, but there was not further study on the order of the procedures. We have no further study about which things put first on our procedure between normalization and imputation. This study is about the identification of differentially expressed genes(DEG) on the order of the preprocessing steps using two-dye cDNA microarray in colon cancer and gastric cancer. That is, we check for compare which combination of imputation and normalization steps can detect the DEG. We used imputation methods(K-nearly neighbor, Baysian principle comparison analysis) and normalization methods(global, within-print tip group, variance stabilization). Therefore, preprocessing steps have 12 methods. We identified concordance measure of DEG using the datasets to which the 12 different preprocessing orders were applied. When we applied preprocessing using variance stabilization of normalization method, there was a little variance in a sensitive way for detecting DEG.

Visual Imaging of Calcium Ion Distribution in Acetone and Tape Stripping Damaged Canine Epidermis (개에서 피부손상에 의한 표피내 칼슘이온 분포상)

  • Oh, Won-Seok;Lee, Keun-Woo;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.3
    • /
    • pp.216-219
    • /
    • 2010
  • The purpose of this study is to establish experimental canine skin barrier disruption model, the study was designed to observe calcium ion in skin frozen tissue of canine skin and also the modulation of calcium ion distribution of normal skin with disrupted skin such as clipping, acetone, tape stripping damages according to time. To compare the changes of calcium ion gradient after damages, the distribution of calcium ion in the canine epidermis was visualized by blotting to gel containing chemical indicator (Calcium Green-1) with fluorescent microscope and the effects of skin barrier damages were examined according to time. Three mins and 1hr after acetone damage, the gradations of epidermis and hair follicle showed more radiant and disappeared after 48 hrs. On the contrary, 3mins and 1hr after tape stripping damage, the gradations showed more radiant than those of acetone damage, and these gradations were stabilized after 48 hrs. The method we presented here could show the visual image of the calcium ions in frozen tissue without further preparation, and it might be useful to investigate the role of calcium ion in the canine epidermal barrier recovery, however, it might be need further methodological improvement to get accurate quantitative information.

SHEAH BOND STRENGTH OF VENEERING CERAMIC TO ELECTROFORMED GOLD WITH THREE DIFFERENT SURFACE TREATMENT (표면처리방법에 따른 전기성형금속의 도재결합강도)

  • Kim Cheol;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.599-610
    • /
    • 2005
  • Purpose: The success of the bonding between electroformed gold and ceramic is dependent on the surface treatment of the pure gold coping. The purpose of this study was to evaluate the bonding strength between the electroformed gold and ceramic with varying surface treatment. Materials and methods: A total of 32 disks,8 were using conventional ceramometal alloy, 24 were using electroforming technique as recommended by manufacturer, were prepared. 24 electroformed disks were divided 3 groups according to surface treatment, i.e. 50 microns aluminium oxide sandblasting(GES-Sand), gold bonder treatment(GES-Bond) and $Rocatec^{TM}$ system(GES-Rocatec). For control group of conventional alloy 50 microns aluminium oxide treatment was done(V-Supragold). Energy dispersive x-ray analysis and scanning electron microscope image were observed. Using universal testing machine, shear bond strength and bonding failure mode at metal-porcelain interface were measured. Results and Conclusion: The following conclusions were drawn: 1. In the energy dispersive x-ray analysis, the Au was main component in electroformed gold(99.9wt%). After surface treatment, a little amount of $Al_2O_3(2.4wt%)$ were found in GES-Sand, and $SiO_2(4wt%)$ in GES-Bond. In GES-Rocatec, however, a large amount of $SiO_2(17.4wt%)$ were found. 2. In the scanning electron microscopy, similar pattern of surface irregu larities were observed in V-Supragold and GES-Sand. In GES-Bond, surface irregularities were increased and globular ceramic particles were observed. In GES-Rocatec, a large amount of silica particles attached to metal surface with increased surface irregularities were observed. 3. The mean shear bond strength values(MPa) in order were $22.9{\pm}3.7(V-Supragold),\;22.1{\pm}3.8(GES-Bond),\;20.1{\pm}2.8(GES-Rocatec)\;and\;13.0{\pm}1.4(GES-Sand)$. There was no significant difference between V-Supragold, GES-Bond, and GES-Rocatec. (P>0.05) 4. Most bonding failures modes were adhesive type in GES-Sand. However, in V-Supragold, GES-Bond and GES-Rocatec, cohesive and combination failures were commonly observed. From the result, with proper surface treatment method electroformed gold may have enough strength compare to conventional ceramometal alloy.

Scientific Investigation for Conservation Methodology of Bracket Mural Paintings of Daeungjeon Hall in Jikjisa Temple (직지사 대웅전 포벽화 보존방안을 위한 과학적 조사)

  • Lee, Hwa Soo;Kim, Seol Hui;Han, Kyeong Soon
    • Journal of Conservation Science
    • /
    • v.34 no.2
    • /
    • pp.107-118
    • /
    • 2018
  • This report does studied for making the method of conserving bracket murals in Daeungjeon of Jikjisa Temple, through the scientific way. Results of evaluated the conservation status at the braket mural paintings, most serious damage is structural damage like cracks, breakage, and delamination. After optical investigation, a characteristic point wasn't found such as underdrawing or traces of a coat of paint. The ultrasonic examination speed by each wall painting was measured from about 195.8 m/s to 392.7 m/s, according to the location of the surface, and it was able to compare the surface properties according to the location. In Infrared-thermal image measurement shows that wall layer separation and paint layer delamination are closely detected, therefore it was able to judge of damage on the objective way. Material analysis revealed that the walls were made by sand and weathering soil. The wall layer combined sand with less than fine sand size by nearly 5:5, and the finishing layer was found to have mixed medium sand and fine sand at approximately 6:4 rates. However, In case of finishing layer, mixing ratios of sizes less than very fine sand were found to be significantly lower than wall. Therefore, it is estimated that the plysical damage such as the separation between the layers of the walls created in the braket mural paintings, is continuously caused by changes in the internal stresses and volume ratio caused by the density differences between the wall and the finishing layers.

Micro-crack Detection in Polycrystalline Solar Cells using Improved Anisotropic Diffusion Model (개선된 비등방 확산 모델을 이용한 다결정형 솔라셀의 마이크로 크랙 검출)

  • Ko, JinSeok;Rheem, JaeYeol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.183-190
    • /
    • 2013
  • In this paper, we propose an improved anisotropic diffusion model for micro-crack detection in heterogeneously textured surface of polycrystalline solar wafers. Due to the nature of the image sensor, the gray-level of the diagonal micro-crack is non-uniform. Thus, the conventional algorithms can't fully detect diagonal micro-cracks when the number of iteration is not enough. However, the increasing of the iteration number leads to increase computation time and detects micro-crack thicker than the original micro-crack. In order to overcome this drawback, we use the gradient of north, south, east, and west directions as well as extended directions. To calculate the diffusion coefficients, we compare the gradients of conventional directions and extended directions and apply the larger gradient values to the coefficient function. This is because the proposed method reflects the information of diagonal micro-crack. Comparing to Tsai et al.'s and Ko and Rheem's, the proposed algorithm shows superior efficiency in detecting the diagonal micro-cracks with less iterations in the images of polycrystalline solar wafers. In addition, it also shows that the thickness of segmented micro-crack is similar to the orignal micro-crack.

Subjective Video Quality Evaluation of H.265/HEVC Encoded Low Resolution Videos for Ultra-Low Band Transmission System (초협대역 전송 시스템상에서 H.265/HEVC 부호화 저해상도 비디오에 대한 주관적 화질 평가)

  • Uddina, A.F.M. Shahab;Monira, Mst. Sirazam;Chung, TaeChoong;Kim, Donghyun;Choi, Jeung Won;Jun, Ki Nam;Bae, Sung-Ho
    • Journal of Broadcast Engineering
    • /
    • v.24 no.6
    • /
    • pp.1085-1095
    • /
    • 2019
  • In this paper, we perform a subjective quality assessment on low-resolution surveillance videos, which are encoded with a very low target bit-rate to use in an ultra-low band transmission system and investigate the encoding effects on the perceived video quality. The test videos are collected based on their spatial and temporal characteristics which affect the perceived quality. H.265/HEVC encoder is used to prepare the impaired sequences for three target bit-rates 20, 45, and 65 kbps and subjective quality assessment is conducted to evaluate the quality from a viewing distance of 3H. The experimental results show that the quality of encoded videos, even at target bit-rate of 45 kbps can satisfy the users. Also we compare objective image/video quality assessment methods on the proposed dataset to measure their correlation with subjective scores. The experimental results show that the existing methods poorly performed, that indicates the need for a better quality assessment method.