• Title/Summary/Keyword: Image Mode

Search Result 864, Processing Time 0.027 seconds

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Implementation of Omni-directional Image Viewer Program for Effective Monitoring (효과적인 감시를 위한 전방위 영상 기반 뷰어 프로그램 구현)

  • Jeon, So-Yeon;Kim, Cheong-Hwa;Park, Goo-Man
    • Journal of Broadcast Engineering
    • /
    • v.23 no.6
    • /
    • pp.939-946
    • /
    • 2018
  • In this paper, we implement a viewer program that can monitor effectively using omni-directional images. The program consists of four modes: Normal mode, ROI(Region of Interest) mode, Tracking mode, and Auto-rotation mode, and the results for each mode is displayed simultaneously. In the normal mode, the wide angle image is rendered as a spherical image to enable pan, tilt, and zoom. In ROI mode, the area is displayed expanded by selecting an area. And, in Auto-rotation mode, it is possible to track the object by mapping the position of the object with the rotation angle of the spherical image to prevent the object from deviating from the spherical image in Tracking mode. Parallel programming for processing of multiple modes is performed to improve the processing speed. This has the advantage that various angles can be seen compared with surveillance system having a limited angle of view.

Merging of SPOT P-mode and XS-mode Images using Color Transformation and Image Enhancement (색변환과 영상개선기법을 이용한 SPOT P-mode와 XS-mode 영상합성)

  • 손덕재;이종훈
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.9 no.2
    • /
    • pp.103-113
    • /
    • 1991
  • The accuracy of input coordinates of ground control points and check points affects great influences to the results of ground coordinate computation in using SPOT digital image data. The original SPOT images displayed on CRT are not usually adequate for identifying the object features and determining the point positioning. Hence, appropriate image processing techniques such as contrast enhancement, subpixel interpolation, edge enhancement, and spatial filtering are needed. In this study, the principles of digital image processing needed for accurate three dimensional positioning and spectral characteristic analysis are investigated. The algorithms for the actual applications are developed and programmed. And using the developed image processing software, some SPOT P-mode and XS-mode images are merged into the SPOT P+XS, the high-resolution color composite image.

  • PDF

Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes (CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가)

  • Byeong-Je Kim;Dong-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.801-808
    • /
    • 2023
  • In order to minimize radiation exposure and secure diagnostic value images during CT examination of the head of children, the usefulness of volume axial mode is evaluated through comparison and analysis of exposure dose and images of volume axial mode, high pitch mode, and helical mode. Image evaluation and dose evaluation were performed in CT high pitch mode, helical mode, and volume axial mode for infants under the age of 1 according to the voltages of 70, 80, and 100 kVp tubes. The image evaluation was conducted by comparing image quality by setting ROI for each image, calculating SNR and CNR, using ONE-WAY (ANOVA) to evaluated statistical significance, and cross-examining the dose evaluation using DLP values displayed in the Dose Report. When inspected using volume axial mode, DLP values were generally low, and SNR and CNR values differed by ROI and kVp. When volume axial mode evaluated the quality of the image compared to other scan modes, the difference is not uniform. For the reason, certain modes are not considered excellent, but the exposure dose was reduced the most in terms of dose. In addition, the point that the volume axial mode can be examined at its original location, short scanning time and needless of table movement is useful for CT tests for children under 1 year of age with high radiation sensitivity.

Bi-dimensional Empirical Mode Decomposition Algorithm Based on Particle Swarm-Fractal Interpolation

  • An, Feng-Ping;He, Xin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.12
    • /
    • pp.5955-5977
    • /
    • 2018
  • Performance of the interpolation algorithm used in the technique of bi-dimensional empirical mode decomposition directly affects its popularization and application, so that the researchers pay more attention to the algorithm reasonable, accurate and fast. However, it has been a lack of an adaptive interpolation algorithm that is relatively satisfactory for the bi-dimensional empirical mode decomposition (BEMD) and is derived from the image characteristics. In view of this, this paper proposes an image interpolation algorithm based on the particle swarm and fractal. Its procedure includes: to analyze the given image by using the fractal brown function, to pick up the feature quantity from the image, and then to operate the adaptive image interpolation in terms of the obtained feature quantity. All parameters involved in the interpolation process are determined by using the particle swarm optimization algorithm. The presented interpolation algorithm can solve those problems of low efficiency and poor precision in the interpolation operation of bi-dimensional empirical mode decomposition and can also result in accurate and reliable bi-dimensional intrinsic modal functions with higher speed in the decomposition of the image. It lays the foundation for the further popularization and application of the bi-dimensional empirical mode decomposition algorithm.

High Efficient Entropy Coding For Edge Image Compression

  • Han, Jong-Woo;Kim, Do-Hyun;Kim, Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.31-40
    • /
    • 2016
  • In this paper, we analyse the characteristics of the edge image and propose a new entropy coding optimized to the compression of the edge image. The pixel values of the edge image have the Gaussian distribution around '0', and most of the pixel values are '0'. By using this analysis, the Zero Block technique is utilized in spatial domain. And the Intra Prediction Mode of the edge image is similar to the mode of the surrounding blocks or likely to be the Planar Mode or the Horizontal Mode. In this paper, we make use of the MPM technique that produces the Intra Prediction Mode with high probability modes. By utilizing the above properties, we design a new entropy coding method that is suitable for edge image and perform the compression. In case the existing compression techniques are applied to edge image, compression ratio is low and the algorithm is complicated as more than necessity and the running time is very long, because those techniques are based on the natural images. However, the compression ratio and the running time of the proposed technique is high and very short, respectively, because the proposed algorithm is optimized to the compression of the edge image. Experimental results indicate that the proposed algorithm provides better visual and PSNR performance up to 11 times than the JPEG.

Pseudo 480-Hz Driving Method for Digital Mode Grayscale Displays

  • Ryeom, Jeongduk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1462-1467
    • /
    • 2013
  • A pseudo 480-Hz drive method has been proposed to reduce the dynamic false contour noise that occurs on flat panel displays with displaying grayscale image in the digital mode, such as plasma display panels. The proposed method makes the image movements nearly continuous by rearranging the 8-bit image data displayed for 1 TV field into 8 subfields. The position of the image data rearranged in subfields has been optimized on the basis of the speed of the moving image by computer simulations for the dynamic false contour noise. It is verified that a significant reduction in the dynamic false contour noise is achieved with the proposed method as compared to the conventional noise reduction technologies. Moreover, to reduce the noise in digital mode displays, the proposed technology requires only 8 subfields. Therefore, there is no reduction in the brightness of the image.

Study on the Quantitativity of Image Sticking in the Fringe-field Switching(FFS) Mode (Fringe-Field Switching (FFS) 모드에서 잔상 정량화에 관한 연구)

  • Seen, Seung-Min;Kim, Mn-Sook;Jung, Yeon-Hak;Kim, Hyang-Yul;Kim, Seo-Yoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.720-723
    • /
    • 2005
  • We studied the quantitativity of the image sticking which is occured by the resicual DC in the fringe-electric field switching (FFS) mode. Actually, in the FFS mode driven by the strong fringe electric field, the asymmetric residual DC was formed in the bottom substrate. It made the impurity ion stick to the alignment layer such as polyimde layer. Thus, the differnece of the luminance existes after the stress check pattern is applied to the panel so that we can see the image sticking. This image sticking decreases as the residual DC value between specific patterns decreases. Therefore, it is necessary to control the residual DC for the FFS mode with the high image quality. It is possible to eliminate the image stiking when the extra pixel voltage is applied through the circuit tunning for reducing the difference of residual DC accroding to the panel position.

Development of a 1-Chip Application-Specific DSP for the Next Generation FAX Image Processing (차세대 팩스 영상처리를 위한 1-Chip Application-Specific DSP 기법)

  • 김재호;강구수;김서규;이진우;이방원;김윤수;조석팔;하성한
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.4
    • /
    • pp.30-39
    • /
    • 1994
  • A 1-chip high quality binarizing VLSI image processor (which has 8 bit ADC. 6 bit flash ADC, 15K standard cell, and 1K word ROM) based on 10 MIPS 16 bit DSP is implemented for FAX. This image processor(IP) performs image pre-processing. image quality improvement in copying and sending mode, and mixed image processing based on the fuzzy theory. And smoothing in sub-scan direction is applied for normal receiving mode data so the received data is enhanced like fine mode data. Each algorithm is processed with the same type of image processing window and 2-D image processing is implemented with a 1-D line buffer. The fabricated chip is applied to a FAX machine and image quality improvement is verified.

  • PDF

Implementation Mode Image Segmentation Method for Object Recognition (물체 인식을 위한 개선된 모드 영상 분할 기법)

  • Moon, Hak-Yong;Han, Wun-Dong;Cho, Heung-Gi;Han, Sung-Ryoung;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.51 no.1
    • /
    • pp.39-44
    • /
    • 2002
  • In this paper, implementation mode image segmentation method for separate image is presented. The method of segmentation image in conventional method, the error are generated by the threshold values. To improve these problem for segmentation image, the calculation of weighting factor using brightness distribution by histogram of stored images are proposed. For safe image of object and laser image, the computed weighting factor is set to the threshold value. Therefore the image erosion and spread are improved, the correct and reliable informations can be measured. In this paper, the system of 3-D extracting information using the proposed algorithm can be applied to manufactory automation, building automation, security guard system, and detecting information system for all of the industry areas.