• Title/Summary/Keyword: Image Matching of Medical Image

Search Result 105, Processing Time 0.024 seconds

Automatic Disk Disease Recognition based on Feature Vector in T-L Spine Magnetic Resonance Image (척추 자기 공명 영상에서 특징 벡터에 기반 한 디스크 질환의 자동 인식)

  • 홍재성;이성기
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.233-242
    • /
    • 1998
  • In anatomical aspects, magnetic resonance image offers more accurate information than other medical images such as X ray ultrasonic and CT images. This paper introduces a method that recognizes disk diseases from spine MR images. In this method, image enhancement, image segmentation and feature extraction for sagittal plane and axial plane images are performed to separate the disk region. And then template matching method is used to extract disease region for axial plane imges. Finally, disease feature vectors are integrated and disease discrimination processes are performed. Experimental results show that the proposed method discriminates between normal and diseased disk with a considerable recognition ratio.

  • PDF

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.4
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

Consideration of the Effect of Artifact during the Image Guided Radiation Therapy Using the Fiducial Marker (영상 유도 방사선치료 시 Fiducial Marker의 Artifact에 관한 연구)

  • Kim, Jong-Min;Kim, Dae-Sup;Back, Geum-Mun;Kang, Tae-Yeong;Hong, Dong-Ki;Yun, Hwa-Yong;Kwon, Kyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Purpose: The effect of artifact was analyzed, which occurs from fiducial marker during the liver Image Guided Radiation Therapy (IGRT) using the fiducial marker. Materials and Methods: The size of artifact of fixed fiducial marker and length of mobile fiducial marker locus were measured using the On-Board Imager system (OBI) and CT simulator, and 2D-2D matching and 3D-3D matching were carried out, respectively, and at this time, the coordinates transition value of couch was analyzed. Results: The measurement of fixed fiducial marker artifact size indicated CT 4.90, 8.10, 12.90, 19.70 mm and OBI 5.60, 10.60, 14.70, 29.40 mm based on the reference CT slice thickness of 1.25, 2.50, 5.00, and 10.00 mm. Meanwhile, the measurement of mobile fiducial marker locus length indicated CT 42.00, 43.10, 46.50 mm, and OBI 43.40, 46.00, 49.30 mm. The coordinates transition of 1.00, 2.00, and 8.00 mm occurred between 2D-2D matching and 3D-3D matching. Conclusion: It was confirmed that the therapy error increased during IGRT due to the influence of artifact when CT slice thickness increased. Thus, it may be desirable to acquire the image less than 2.50 mm in slice thickness when IGRT is implemented using the fiducial marker.

  • PDF

Development of an image processing system to detect automatically intimal and adventitial contours from intravascular ultrasound images (관상동맥 혈관내부 초음파 영상에서 내벽 및 외벽 윤곽선 자동추출을 위한 영상처리 알고리즘 개발)

  • Kim, H.S.;Dove, E.L.;Chandran, K.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.27-31
    • /
    • 1994
  • Intravascular ultrasound images of coranary artery contain very important informations on heart disease. The intimal contours on the image show informations and data to examine intravascular problems of patients. A new computation algorithm to detect the intimal and adventitial contours from the intravascular images was developed. An Image processing on gray level image was used. It uses arrays of pixels in each radial lines on the images. A "Robert" filter was adopted at first step for one dimensional image processing. Some other calculation techniques were developed to inclose the accuracy of automatically detected contours. The standard contour data to compare with automatically detected contour data were obtained through manually tracing by experienced cardiological medical doctors. The result of the new algorithm shows high accuracy of 80 % matching with the standard contour data.

  • PDF

Image Mosaic from a Video Sequence using Block Matching Method (블록매칭을 이용한 비디오 시퀀스의 이미지 모자익)

  • 이지근;정성태
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1792-1801
    • /
    • 2003
  • In these days, image mosaic is getting interest in the field of advertisement, tourism, game, medical imaging, and so on with the development of internet technology and the performance of personal computers. The main problem of mage mosaic is searching corresponding points correctly in the overlapped area between images. However, previous methods requires a lot of CPU times and data processing for finding corresponding points. And they need repeated recording with a revolution of 360 degree around objects or background. This paper presents a new image mosaic method which generates a panorama image from a video sequence recorded by a general video camera. Our method finds the corresponding points between two successive images by using a new direction oriented 3­step block matching methods. Experimental results show that the suggested method is more efficient than the methods based on existing block matching algorithm, such as full search and K­step search algorithm.

Analysis of Uncertainties due to Digitally Reconstructed Radiographic (DRR) Image Quality in 2D-2D Matching between DRRs and kV X-ray Images from the On-Board Imager (OBI) (디지털 재구성 방사선영상과 온보드 영상장치를 이용한 2D-2D 정합 시 디지털 재구성 방사선영상의 질이 정합 정확도에 미치는 영향 분석)

  • Cheong Kwang-Ho;Cho Byung-Chul;Kaug Sei-Kwon;Kim Kyoung-Joo;Bae Hoon-Sik;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.67-76
    • /
    • 2006
  • We evaluated the accuracy of a patient setup error correction due to reference image quality for a 2D-2D matching process. Digitally reconstructed radiographs (DRRs) generated by use of the Pinnacle3 and the Eclipse for various regions of a humanoid phantom and a patient for different CT slice thickness were employed as a reference images and kV X-ray Images from the On-Board Imager were registered to the reference DRRs. In comparison of the DRRs and profiles, DRR image quality was getting worse with an increase of CT image slice thickness. However there were only slight differences of setup errors evaluation between matching results for good and poor reference DRRs. Although DRR image quality did not strongly affect to the 2D-2D matching accuracy, there are still potential errors for matching procedure, therefore we recommend that DRR images are needed to be generated with less than 3mm slice thickness for 2D-2D matching.

  • PDF

Image Fusion of Lymphoscintigraphy and Real images for Sentinel Lymph Node Biopsy in Breast Cancer Patients (유방암 환자의 감시림프절 생검을 위한 림포신티그라피와 실사영상의 합성)

  • Jeong, Chang-Bu;Kim, Kwang-Gi;Kim, Tae-Sung;Kim, Seok-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.2
    • /
    • pp.114-122
    • /
    • 2010
  • This paper presents a method that registers a lymphoscintigraphy to the real image captured by a CMOS camera, which helps surgeons to easily and precisely detect sentinel lymph nodes for sentinel lymph node biopsy in breast cancer patients. The proposed method consists of two steps: pre-matching and image registration. In the first step, we localize fiducial markers in a lymphoscintigraphy and a real image of a four quadrant bar phantom by using image processing techniques, and then determines perspective transformation parameters by matching with the corresponding marker points. In the second step, we register a lymphoscintigraphy to a real images of patients by using the perspective transformation of pre-matching. To examine the accuracy of the proposed method, we conducted an experiment with a chest mock-up with radioactive markers. As a result, the euclidean distance between corresponding markers was less than 3mm. In conclusion, the present method can be used to accurately align lymphoscintigraphy and real images of patients without attached markers to patients, and then provide useful anatomical information on sentinel lymph node biopsy.

Image-guided Surgery System Using the Stereo Matching Method (스테레오 매칭 기법을 이용한 영상유도시술 시스템)

  • 강현수;이호진;문찬홍;문원진;김형진;최근호;함영국;이수열;변홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.4
    • /
    • pp.339-346
    • /
    • 2003
  • MRI provides anatomical structure information with superb spatial resolution that can be utilized in clinical surgeries. Advanced image processing techniques in conjunction with the MRI-guided surgery is expected to be of great importance in brain surgeries in the near future. In this paper, we introduce an image-guided surgery technique using the stereo matching method. To perform image-guided biopsy operations, we made MRI markers, camera markers and a detection probe marker. To evaluate the accuracy of the image-guided system. we made a silicone phantom. Using the phantom and markers, we have performed MRI-guided experiments with a 1.5 Tesla MRI system. It has been verified from phantom experiments that our system has a positioning error less than 1.5%. Compared with other image guided surgery system, our system shows better positioning accuracy.

Correction of Ocular Fundus Fluorescein Angiogram in Nonlinear Distortion (비선형왜곡된 형광안저화상의 보정)

  • 고창림
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.31-38
    • /
    • 1990
  • Image correction of the fluorescein angiogram with the low contrast and geometrically distorted is studied. The procedure is divided into two steps : A template matching step and a geometrical transformation step. Based on the sequential similiarity detection algorithm, more Improved matching results are obtained with edge enhanced image. For the reference points and the corresponding matchimg points, the geometrical transformationss by the use of the average value of the X, Y translational shifts and a pair of these points, respectively are described. Then the corrected images are obtained using bilinear interpolation. It is proven that the usefullness of this study for the image correction of the ocular fundus fluoresceln angiogram with low contrast and geometrically distorted mainly due to the eye movements.

  • PDF

Appearance-Order-Based Schema Matching

  • Ding, Guohui;Cao, Keyan;Wang, Guoren;Han, Dong
    • Journal of Computing Science and Engineering
    • /
    • v.8 no.2
    • /
    • pp.94-106
    • /
    • 2014
  • Schema matching is widely used in many applications, such as data integration, ontology merging, data warehouse and dataspaces. In this paper, we propose a novel matching technique that is based on the order of attributes appearing in the schema structure of query results. The appearance order embodies the extent of the importance of an attribute for the user examining the query results. The core idea of our approach is to collect statistics about the appearance order of attributes from the query logs, to find correspondences between attributes in the schemas to be matched. As a first step, we employ a matrix to structure the statistics around the appearance order of attributes. Then, two scoring functions are considered to measure the similarity of the collected statistics. Finally, a traditional algorithm is employed to find the mapping with the highest score. Furthermore, our approach can be seen as a complementary member to the family of the existing matchers, and can also be combined with them to obtain more accurate results. We validate our approach with an experimental study, the results of which demonstrate that our approach is effective, and has good performance.