• Title/Summary/Keyword: Image Intensity

Search Result 1,695, Processing Time 0.043 seconds

A Study on the Characteristics of Methane-Air Premixture Combustion and Combustion Radicals (II) (밀폐 연소실 내의 메탄-공기 예혼합기의 연소 및 라디칼 특성에 관한 연구(II))

  • Choe, Su-Jin;Jeon, Chung-Hwan;Jang, Yeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.602-614
    • /
    • 1997
  • In order to evaluate the effects of equivalence ratio, initial pressure and temperature on the laminar flame propagation process, and combustion radicals characteristics, experimental approaches are carried out in methane-air premixture using a constant volume chamber. Local and average radical intensities were measured to determine the time and spatial correlations between each radicals; C $H^{*}$(431 nm), $C_{2}$$^{*}$ (517 nm) and O $H^{*}$(309 nm) . The results are showed that two kinds of equation were proposed for the cases of continuous flame and intermittent flame type to evaluate actual equivalence ratio using relative intensities with each radicals. Both equations were agreed with actual equivalence ratio within 10% errors range. And schlieren photo and CCD image were compared with flame sizes at equivalence ratio 1.0.o 1.0.

Hypointensity on Susceptibility-Weighted Images Prior to Signal Change on Diffusion-Weighted Images in a Hyperacute Ischemic Infarction: a Case Study

  • Kim, Dajung;Lee, Hyeonbin;Jung, Jin-Man;Lee, Young Hen;Seo, Hyung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.131-134
    • /
    • 2018
  • Susceptibility-weighted imaging (SWI) is well known for detecting the presence of hemorrhagic transformation, microbleeds and the susceptibility of vessel signs in acute ischemic stroke. But in some cases, it can provide the tissue perfusion state as well. We describe a case of a patient with hyperacute ischemic infarction that had a slightly hypodense, patchy lesion at the left thalamus on the initial SWI, with a left proximal posterior cerebral artery occlusion on a magnetic resonance (MR) angiography and delayed time-to-peak on an MR perfusion performed two hours after symptom onset. No obvious abnormal signals at any intensity were found on the initial diffusion-weighted imaging (DWI). On a follow-up MR image (MRI), an acute ischemic infarction was seen on DWI, which is the same location as the lesion on SWI. The hypointensity on the initial SWI reflects the susceptibility artifact caused by an increased deoxyhemoglobin in the affected tissue and vessels, which reflects the hypoperfusion state due to decreasing arterial flow. It precedes the signal change on DWI that reflects a cytotoxic edema. This case highlights that, in some hyperacute stages of ischemic stroke, hypointensity on an SWI may be a finding before the hyperintensity is seen on a DWI.

Development and Implementation of Statistical Edge Detectors on the Web (웹 상에서 통계적 에지검출기 개발 및 구현)

  • Lim, Dong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.133-141
    • /
    • 2005
  • An edge is where the intensity of an image moves from a low value to high value or vice versa. The edges tell where objects are. their shape and size. and something about their texture. Many traditional edge operators are derivative based and perform reasonably well for simple noise-free images. In recent, statistical edge detectors for complex images with noises have been described. This paper compares and analysis the performance of statistical edge detectors based on the T test and Wilcoxon test, and mathematical edge detectors based on Sobel operator, and the well-known Canny detector and Wavelet transformation detector, and provides the implementation of these edge detectors using Java on the web.

  • PDF

Feasibility Study of Determining the Healing Phase of Achilles Tendon Rupture in Rats Using Optical Coherence Tomography

  • Kim, Young-Sik;Chae, Yu-Gyeong;Jeon, Min Yong;Kim, Dong Kyu;Ahn, Yeh-Chan
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.175-181
    • /
    • 2015
  • Optical coherence tomography (OCT) is a noninvasive technique for microscopic investigation of tissue. We thought that the OCT method could be a potential tool for monitoring the healing process of a tendon. In this study we used two rat models, denervated and non-denervated groups, to observe a variety of healing phases of Achilles tendon (AT) injury. We made samples of AT injury lesions, to take OCT images and to make histopathological samples of serial sectional tissue. In an OCT image the denervated rat showed no specific finding, but the non-denervated rat showed a large defect lesion that was scaffolding tissue. OCT findings combined with pathologic findings showed advantages in visualization of tendon microstructure over other imaging modalities such as MRI and US, and OCT is beneficial to making a treatment plan, especially the timing and intensity of rehabilitation. Therefore a multimodal platform using OCT for evaluation of tendon injury may be potentially useful for many applications.

Four-beam Interference Optical System for Laser Micro- structuring Using Picosecond Laser

  • Noh, Ji-Whan;Lee, Jae-Hoon;Shin, Dong-Sig;Sohn, Hyon-Kee;Suh, Jeong;Oh, Jeong-Seok
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • A four beam interference optical system for laser micro structuring using a pulse laser was demonstrated. The four beam interference optical system using a pulse laser(picosecond laser) can fabricate micro structure on mold material(NAK80) directly. Micro structure on the polymer can be reproduced economically by injection molding of the micro structure on the mold material. The four beam interference optical system was composed by the DOE(Diffractive Optical Element) and two lenses. The laser intensity distribution of four beam interference was explained by an interference optics point of view and by the image optics point of view. We revealed that both views showed the same result. The laser power distribution of a $1{\mu}m$ peak pattern was made by the four beam interference optical system and measured by the objective lens and CCD. A $1{\mu}m$ pitch dot pattern on the mold material was fabricated and measured by SEM(Scanning Electron Microscopy).

Differential imaging diagnosis of a swelling after extraction in a breast cancer patient with radiotherapy and chemotherapy (방사선치료와 화학요법을 받은 유방암 환자에서 발생한 발치 후 종창의 진단영상학적 감별 진단)

  • Huh Kyung-Hoe;An Byung-Mo;Kim Mi-Ja;Park Kwan-Soo;Heo Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.163-168
    • /
    • 2006
  • A 60-year-old female, who complained of delayed healing and swelling after extraction of left lower second molar during chemotherapy, visited our department. She had a history of a resection surgery of breast cancer and postoperative radiotherapy. The conventional radiographs showed diffuse permeative bone destruction in posterior mandibular body, which gave the first radiologic impression of osteonecrosis associated with radiotherapy or chemotherapy. And bone metastasis from the breast cancer was also considered in the differential diagnosis. On the enhanced computed tomography (ECT) the posterior mandibular body was occupied by a large expansile lesion showing central low attenuation with peripheral rim enhancement. Magnetic resonance images revealed that the low attenuated area on ECT did not show as high signal intensity as water on T2 weighted image and indicated solid component of a tumor. The final diagnosis was central squamous cell carcinoma. We present the diagnostic imaging features of the patient with special emphasis on the differential diagnosis.

  • PDF

Segmentation of Arterial Vascular Anatomy around the Stomach based on the Region Growing Based Method

  • Kang, Jiwoo;Kim, Doyoung;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.75-79
    • /
    • 2014
  • Purpose The region growing has a critical problem that it often extract vessels with unexpected objects such as a bone which has a similar intensity characteristics to the vessel. We propose the new method to extract arterial vascular anatomy around the stomach from the CTA volume without the post-processing. Materials and Methods Our method, which is also based on the region growing, requires the two seed points from the use. I automatically extracts perigastric arteries using the adaptive region growing method and it does not need any post-processing. Results The three region growing based methods are used to extract perigastric arteries - the conventional region growings with restrict and loose thresholds each and the proposed method. The 3D visualization from the result of our method shows our method extracted the all required arteries for gastric surgery. Conclusion By extracting perigastric arteries using the proposed method, over-segmentation problem that unexpected anatomical objects such as a rib or backbone are also segmented does not occurs anymore. The proposed method does not need to sensitively determine the thresholds of the similarity function. By visualizing the result, the preoperative simulation of arterial vascular anatomy around the stomach can be possible.

Simultaneous observations of SiO v=1 and v=2, J=1-0 masers toward WX Pisces with the KVN+VERA

  • Yun, Youngjoo;Cho, Se-Hyung;Imai, Hiroshi;Kim, Jaeheon;Yoon, Dong-Hwan;Cho, Chi-Young
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.238.1-238.1
    • /
    • 2012
  • We present the results of simultaneous observations of SiO v=1 and 2, J=1-0 maser lines which were carried out with the combined network of the KVN and VERA in 2012 April. The observations were performed toward a long period OH/IR star, WX Psc in order to test the technical and scientific feasibilities of the KVN+VERA combination. The resultant (u, v) coverage of the KVN+VERA combined array enhances the image quality. We confirmed that the distribution and intensity of individual maser spots using the combined network are more reliable compared with the images using the KVN or VERA only. This observation also provides a chance to find a high sensitivity and imaging quality which are comparable to those of VLBA. In addition, the simultaneous observations of two SiO v=1 and 2, J=1-0 maser lines enable us to trace the detail physical environments close to the central star due to different high excitation conditions between two lines at a time.

  • PDF

A Study on the Color Edge Detection (컬러 에지 검출에 관한 연구)

  • 김동현;이소행;정진용;양현호;최우진
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.3
    • /
    • pp.8-12
    • /
    • 1999
  • Edge detection is a key component for many modern computer vision applications. While it is certainly not the only way to identify an object, or track a feature, it can be one of the most convenient if it is done quickly and consistently. Many algorithms proposed is applied to gray level images. But. there are limits in method using only intensity information, so, many researchers has try to done research about using color information. In this paper, we propose the new edge detection method usign color information, implement the widely used algorithms and compared with them in performance. In result of experiment, we show that the proposed algorithm have better result in fine detail and shaded region of image.

Tracking of Continuously Acting Hearts Using a Geometric Active Contour Model (기하 활성 모델을 이용한 연속적 심장 운동 추적)

  • 김성곤
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.4
    • /
    • pp.17-22
    • /
    • 2002
  • This paper used an active contour model which was based on level set algorithms and bidirectional curve evolution theory in order to track the shape of the heart acting continuously. Most active contour models would be failed in boundary extraction because of their unstable movement in the edge gap locations. In this paper, we suggest a new active contour model using only image intensity value and additional constraint needed for stable extraction. Our model was successfully run on either shape extraction or object tracking without any position constraints of initial curve. Also demonstrated stable movements and showed good results at weak or missing boundary locations.

  • PDF