• Title/Summary/Keyword: Illumination measurement

Search Result 234, Processing Time 0.034 seconds

Improvement the Junction Temperature Measurement System Considering the Parasitic Capacitance in LED (LED 기생 커패시턴스를 고려한 접합온도 측정 시스템의 개선)

  • Park, Chong-Yun;Yoo, Jin-Wan
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.187-191
    • /
    • 2009
  • Recently, we have used LEDs to illumination because it has a high luminous efficiency and prolong lifespan. However the light power and lifetime is reduced by junction temperature increment of LED. So it is important to measure the junction temperature accurately. In case of using a electrical method measuring junction temperature of LED. Temperature measurement errors are spontaneously generated because of a parasitic capacitances in LED. In this paper, we proposed a method that reducing LED's parasitic capacitance effects for electrical measurement. It was demonstrated by the experimental result that is more correct than established method.

  • PDF

A Method of Wood Section Measuring and the Image Calibration Using Line Laser (Line Laser 를 이용한 목재단면 측정 및 영상보정 방법)

  • Kim, Gi Hwan;Park, Min Su;Kim, Do Yeop;Lee, Suk Yong;Lee, Eung Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.8
    • /
    • pp.641-646
    • /
    • 2016
  • The best method of measuring wood diameter is a contact-type device: however, obtaining an accurate result can be problematic under certain circumstances. In this study, we used a laser beam and a CCD camera that did not require contact with wood. The wood is illuminated by the laser beam, and the CCD camera captures this illumination. The measurement results were determined by processing of the captured image sequences. This paper explains the use of image processing and laser systems for measurement of wood under circumstances in which physical contact is impossible.

Development of a Measurement System for Axial-symmetric Objects Using Vision Sensor (시각센서를 이용한 축대칭 물체 측정 시스템 개발)

  • Lee, S.R.;Kim, C.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.5
    • /
    • pp.34-41
    • /
    • 1997
  • The dimension measurement problem of products has been a major concern in the quality control in the industrial fields. A non-contacting measurement system using the vision sensor is proposed in this paper. The system consists of a CCD camera for the image capture, a frame grabber for the acquired image processing, a laser unit for the illumination, scanning unit for the measurement, and a personal computer for the geometry computation. The slit beam which is generated by passing the laser beam through a cylin- drical lens is fired to the axial-symmetric object on the rotating plate. The image of objects reflected by the laser slit beam, acquired by the CCD camera, becomes much brighter than the other parts of objects. After the histogram of brightness for the captured image is calculated, low intensity pixels are filtered out by threshold method. The performance of proposed measurement system is obtained for several different axial symmetric objects. The proposed system is verified as a good tool for measuring axial-symmetric parts in a limited condition with a minor investment cost.

  • PDF

The Toxicity Test of Water Flea by Heartbeat Measurement (물벼룩의 심장박동을 이용한 독성실험)

  • Lee, Chan-Won;Kim, In-Kyung;Jeon, Hong-Pyo
    • Journal of Environmental Science International
    • /
    • v.16 no.4
    • /
    • pp.425-432
    • /
    • 2007
  • The water flea has been used as a test organism of toxicity test for surface water. Toxicity test with water flea is categorized into two parts. One is acute toxicity test with observing immobility and mortality and the other is chronic toxicity test determined by survival and reproduction of water flea. Heartbeat measurement of water flea was designed as a short-term toxicity test in this study. Direct measurement of heartbeat under microscope by aid of video camera gives and early diagnosis of mortality in short time. Therefore, the effects of measuring illumination, measuring time, and non-feeding during the test on heartbeat of water flea was evaluated to establish a new test approach. Test organisms used in this study are Daphnia magna, a well standardizes toxicity test organism, and Simocephalus mixtus, a newly refined organism $IC_{50}$ values of these test organism by heartbeat measurement were compared and discussed. It was found that toxicity test by heartbeat measurement was a reproducible, easy and simple method accomplished in a few hours.

Development of a Real-time 3D Intraoral Scanner Based on Fringe-Projection Technique (프린지 투영법을 이용한 실시간 3D 구강 내 스캐너의 개발)

  • Ullah, Furqan;Lee, Gunn-Soo;Park, Kang
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.156-163
    • /
    • 2012
  • Real-time three-dimensional shape measurement is becoming increasingly important in various fields, including medical sciences, high-technology industry, and microscale measurements. However, there are not so many 3D profile tools specially designed for specifically narrow space, for example, to scan the tooth shape of a human jaw. In this paper, a real-time 3D intraoral scanner is proposed for the measurement of tooth profile in the mouth cavity. The proposed system comprises a laser diode beam, a micro charge-coupled device, a graticule, a piezoelectric transducer, a set of optical lenses, and a polhemus device sensor. The phase-shifting technique is used along with an accurate calibration method for the measurement of the tooth profile. Experimental and theoretical inspection of the phase-to-coordinate relation is presented. In addition, a nonlinear system model is developed for collimating illumination that gives the more accurate mathematical representation of the system, thus improves the shape measurement accuracy. Experiment results are presented to verify the feasibility and performance of the developed system. The experimental results indicate that overall measurement error accuracy can be controlled within 0.4 mm with a variability of ${\pm}0.01$.

The Design and Implementation of remote measurement using Internet Embedded Module (인터넷 엠베디드 모듈을 이용한 원격 계측의 설계와 구현)

  • Lee, Hee-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.9 no.5
    • /
    • pp.183-190
    • /
    • 2008
  • Recently, according to development of information-oriented society, internet application technology on electricity electron controled technology fields are diversified and the necessity of remote measurement by internet is gradually increased. In this paper, to meet in these necessity we design and implementation of remote measurement system using internet embedded module, which was developed for on-line measurement of various kinds of analogue data. This system is consisted of two parts greatly, hardware module for measurement and software module to control it. The advantage of this system is that users can acquisition the remote data of temperature and illumination etc. without extra serve pc easily. In order to test the validity of the proposed system, we examine the response and operating characteristic about several states. As a result of the test, we proved the effectiveness of it.

  • PDF

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

Robustness of Display Hemispherical Reflectance Measurement Apparatus

  • Penczek, John;Kelley, Edward F.;Kim, Seung-Kwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1355-1357
    • /
    • 2008
  • Reflection measurements are critical to the evaluation of display performance under ambient illumination conditions. Various hemispherical reflection methods are evaluated for their suitability and robustness across display technologies. The standard integrating sphere method is compared to a sampling sphere apparatus.

  • PDF

A survey of actual conditions on the Kindergarten attached to colleges through actual measurement (실측을 통한 대학부설 유치원의 실태분석)

  • 석주영
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.10a
    • /
    • pp.51-55
    • /
    • 1994
  • This study was attempted to investigate the facilities and environments of kindergarten attached to colleges, and ultimately to make up the adequate environment of for children. For these purposes, investigators directly visited 6 kimdergartens attached to colleges, and actually measured the facilities and equipments of these kindergartens. Concretely, our invetigators analyzed the actual conditions of kindergarten attached to colleges contering around the lighting and illumination of classroom, corridor, hall, toile room, dining room, and furnitures, closing materials of the floor, wall, ceiling.

  • PDF