• Title/Summary/Keyword: Illumination measurement

Search Result 234, Processing Time 0.023 seconds

Li:Al cathode layer and its influence on interfacial energy level and efficiency in polymer-based photovoltaics

  • Park, Sun-Mi;Jeon, Ji-Hye;Park, O-Ok;Kim, Jeong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.72-72
    • /
    • 2010
  • Recent development of organic solar cell approaches the level of 8% power conversion efficiency by the introduction of new materials, improved material engineering, and more sophisticated device structures. As for interface engineering, various interlayer materials such as LiF, CaO, NaF, and KF have been utilized between Al electrode and active layer. Those materials lower the work function of cathode and interface barrier, protect the active layer, enhance charge collection efficiency, and induce active layer doping. However, the addition of another step of thin layer deposition could be a little complicated. Thus, on a typical solar cell structure of Al/P3HT:PCBM/PEDOT:PSS/ITO glass, we used Li:Al alloy electrode instead of Al to render a simple process. J-V measurement under dark and light illumination on the polymer solar cell using Li:Al cathode shows the improvement in electric properties such as decrease in leakage current and series resistance, and increase in circuit current density. This effective charge collection and electron transport correspond to lowered energy barrier for electron transport at the interface, which is measured by ultraviolet photoelectron spectroscopy. Indeed, through the measurement of secondary ion mass spectroscopy, the Li atoms turn out to be located mainly at the interface between polymer and Al metal. In addition, the chemical reaction between polymer and metal electrodes are measured by X-ray photoelectron spectroscopy.

  • PDF

Development of Nipkow Disk for High-Speed Confocal Probe Using Micro-lens and Pinhole Disks (마이크로 렌즈 디스크와 핀홀 디스크를 이용한 고속 공초점용 닙코 디스크 개발)

  • Kim, Gee Hong;Lee, Hyung Seok;Kim, Chang Kyu;Lim, Hyung Jun;Lee, Jae Jong;Choi, Kee Bong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.636-641
    • /
    • 2014
  • This paper discusses the fabrication process for a Nipkow disk using micro-lens and pinhole disks. The confocal measuring system that uses the Nipkow disk has the advantage in measuring speed, because the Nipkow disk can simultaneously provide confocal images of all pixels in a CCD camera without requiring a lateral scanning unit. A micro-lens configuration, which focuses illumination on a pinhole, overcomes the low optical efficiency of the Nipkow disk system and allows its use in practical applications. This paper describes how to design the Nipkow disk in terms of numerical aperture, particularly for measuring the height of solder bumps in packaging application and for hybrid processes combining mechanical and semiconductor processes.

3D Measurement of TSVs Using Low Numerical Aperture White-Light Scanning Interferometry

  • Jo, Taeyong;Kim, Seongryong;Pahk, Heuijae
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.317-322
    • /
    • 2013
  • We have proposed and demonstrated a low numerical aperture technique to measure the depth of through silicon vias (TSVs) using white-light scanning interferometry. The high aspect ratio hole like TSV's was considered to be impossible to measure using conventional optical methods due to low visibility at the bottom of the hole. We assumed that the limitation of the measurement was caused by reflection attenuation in TSVs. A novel interference theory which takes the structural reflection attenuation into consideration was proposed and simulated. As a result, we figured out that the low visibility in the interference signal was caused by the unbalanced light intensity between the object and the reference mirror. Unbalanced light can be balanced using an aperture at the illumination optics. As a result of simulation and experiment, we figured out that the interference signal can be enhanced using the proposed technique. With the proposed optics, the depth of TSVs having an aspect ratio of 11.2 was measured in 5 seconds. The proposed method is expected to be an alternative method for 3-D inspection of TSVs.

A Miniaturized Catadioptric Laser-Irradiation-Precision Test System

  • Liu, Huan;Sun, Hao;Wang, Chunyan
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.164-172
    • /
    • 2021
  • In this paper a catadioptric laser-irradiation-precision test system is designed, to achieve a high-precision laser-irradiation-accuracy test. In this system, we adopt the method of imaging the entire target surface at a certain distance to realize the measurement of laser-irradiation precision. The method possesses the advantages of convenient operation, high sensitivity, and good stability. To meet the test accuracy requirement of 100 mm/km (0.01%), the coma, field curvature, and distortion over the entire field of view should be eliminated from the optical system's design. Taking into account the whole length of the tube and the influence of stray light on the structure type, a catadioptric system with a hood added near the primary imaging surface is designed. After optimization using the ZEMAX software, the modulation transfer function (MTF) of the designed optical system is 0.6 at 30 lp/mm, the full-field-of-view distortion is better than 0.18%, and the energy concentration in the 10-㎛-radius surrounding circle reaches about 90%. The illumination-accuracy test results show that the measurement accuracy of the radiation hit rate is better than 50 mm when the test distance is 1 km, which is better than the requirement of 100 mm/km for the laser-irradiation-accuracy test.

Fabrication of 3D Feed Horn IR Antenna for IR Detector

  • Kim, Kun-Tae;Han, Yong-Hee;Shin, Hyun-Joon;Sung Moon;Park, Jung-Ho
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.170-175
    • /
    • 2004
  • A three dimensional feed horn 10${\mu}{\textrm}{m}$ wavelength infrared antenna has been suggested, fabricated and characterized. It was applied to an infrared detector for efficient collecting of IR radiation and for reducing background noise. The horn antenna size was designed for maximum antenna directivity. The 3D feed horn antenna mold was fabricated using rotating and tilted illumination while the antenna plate was constructed by way of electroplating. Antenna characteristics were measured by coupling with a microbolometer. Measurement results indicated that the directivity of the antenna is 16.1㏈ and the background noise is reduced by approximately two times.

Polarization Spectral Imaging System for Quantitative Evaluation of Port Wine Stain Blanching Following Laser Treatment

  • Jung, Byung-Jo
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.234-239
    • /
    • 2003
  • Objective methods to assess quantitatively port wine stain (PWS) blanching in response to laser therapy are needed to improve laser therapeutic outcome. Previous studies have attempted to assess objectively PWS color based on point measurement devices. To date, these approaches have typically been limited by a number of factors such as small test area and need for contact. To address these issues, a polarization spectral imaging system and an image analysis method have been developed to evaluate quantitatively erythema and melanin content distribution in skin. The developed polarization spectral imaging system minimizes artifacts such as glaring, shadowing, and non-uniform illumination that interfere with image fidelity. Furthermore, the image analysis method has been employed to get images of skin melanin and erythema indices from the acquired color images for quantitative analysis. Finally, using PWS patient color image, the effectiveness in laser treatment of PWS was evaluated by calculating relative erythema index image that is the relative erythema index of PWS region to the normal region. The developed device and analysis method appears to be a simple and effective method for quantitative analysis of PWS blanching.

The Color Enhancement of TV Picture by the Color Measurement of Illumination (광원의 색채 계측에 의한 TV 화상의 색 향상)

  • 이응주;정인갑;박양우;이광춘;하영호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.1
    • /
    • pp.47-58
    • /
    • 1996
  • An object color can be seen differently under the various outer illuminants. However, human visual system has color constnacy that the object color can be seen constantly under the different outer illuminants. When the viewer watches TV under specific that the object color can be seen constantly under the different outer illuminants. When the viewer bathes TV under specific outer illuminants, he perceives distortes color due to the emitting specturm of outer illuminants as well as the radiation of CPT itself. Namely, when the outer illuminants such as fluorescent and incandescent lamps incident on CPT, brightness, saturation, hue, itself. Namely, when the outer iluminants such as fluorescent and incandescent lamps incident on CPT, brightness, saturation, hue, and contrast on color pictures are changend, he perceives distortedcolr fromthe original color. In this paper color enhancement algorithm based on light intensity and outer light decision funtion using RGB sensor was proposed. The implemented TV of proposed algorithm has higher visual quality at the view point of human visual system and more vivid than that ofcoventional color TV.

  • PDF

PIV measurement of step cavity with driven flow (구동류를 갖는 계단 캐비티의 PIV계측)

  • 조대환;김진구;이영호
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • An experimental study was carried out in a three-dimensional cubic cavity driven by 2-dimensional plane Poiseuille flow for three kinds of Reynolds number, $10^4$, 3 $\times$ $10^4$ and 5 $\times$ $10^4$ based on the cavity width and cavity inlet mean flow velcoity. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system. Laser based illumination and two-frame grey-level cross correlation algorithm are adopted. Severe unsteady flow fluctuation within the cavity are remarkable at above Re = 3 $\times$ $10^4$ Reynolds numbers and sheared mixing layer phenomena are also found at the region where inlet driving Poiseuille flow is collided with the clock-wise rotating main primary vortex at upper center area. Instant velocity profiles reveal that deformed forced vortex formation is observed throughout the separate two areas.

  • PDF

Simultaneous measurement of in-plane and out-of-plane displacement using holographic interferometry (홀로그래피 간섭계를 이용한 횡변위와 종변위의 동시 측정)

  • 김달우;임부빈
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.4
    • /
    • pp.267-276
    • /
    • 1997
  • We set up a four-wave holographic interferometer using a symmetric dual-beam illumination which is to measure in-plane and out-of-plane displacement simultaneously. In order to acquire the displacement phase map we applied the phase-shifting method and removed the noise of the phase map with least-squares fitting. In this approach the access to information relative to both the difference and sum of phases existing in the two arms of four-wave holographic interferometer was allowed. As a result, in-plane and out-of-plane displacement was measured to the accuracy of λ/40 and λ/100, respectively at λ=632.8nm

  • PDF

Research about Tool Wear Monitoring in CNC Lathe Machining (선삭 공정에서 공구모니터링에 관한 연구 (I)-공구마모)

  • Go, Jeong-Han;Kim, Yeong-Tae;Lee, Sang-Jo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.54-60
    • /
    • 2000
  • Research about tool condition monitoring has been done until now for product automation and unmaned system. But it is hard to apply it to the industrial field due to its cost and reliability. This paper presents the new method of tool wear measurement using Marpos gauge. This is a kind of touch sensor, so its cost is lower than vision system. And it is not affected by dust and illumination, which are important in vision system. This proposed method use tool clearance angle to measure flank wear. Experimental results compared with vision system shows that this method is available for tool condition monitoring system.

  • PDF