• Title/Summary/Keyword: ITS test

Search Result 14,310, Processing Time 0.048 seconds

A Study on the Cause and Countermeasures of the Short-Circuit Test Failures of the Distribution Transformer (배전용 변압기의 단락시험 불량원인 및 그 대책에 관한 연구)

  • Park, Byung-Rak;Park, Hoon-Yang;Shin, Hee-Sang;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.75-81
    • /
    • 2011
  • This study aims to research and analyze the cause and countermeasures of the short-circuit test failures of the distribution transformer, which captures failure share at the highest level when carrying out its performance test. For this purpose, the research was done on the basis of 77 failure cases out of 998 tests in total performed by the Korea Electrotechnology Research Institute(KERI) from 2004 to 2010. Based on the research, the paper also includes analysis of the causes of the short-circuit test failures in its early stage of transformer development and proposes its countermeasures accordingly.

Maximum entropy test for infinite order autoregressive models

  • Lee, Sangyeol;Lee, Jiyeon;Noh, Jungsik
    • Journal of the Korean Data and Information Science Society
    • /
    • v.24 no.3
    • /
    • pp.637-642
    • /
    • 2013
  • In this paper, we consider the maximum entropy test in in nite order autoregressiv models. Its asymptotic distribution is derived under the null hypothesis. A bootstrap version of the test is discussed and its performance is evaluated through Monte Carlo simulations.

An Improved Estimator of PPV from the Screening Test

  • Park, Sang-Gue;Choi, Ji-Yun
    • Journal of the Korean Data and Information Science Society
    • /
    • v.16 no.2
    • /
    • pp.419-428
    • /
    • 2005
  • The screening test is increasingly being used for predicting future disease in the person screened and has raised concerns about reliability of the result of its procedure. We propose an improved estimator of the confidence interval for the positive predictive value(PPV) in screening test by simply taking inverse sinh transformation comparing to Gastwirth(1987) estimator and show its efficiency through the simulation study.

  • PDF

Experimental Analysis of V2X Communication Performance based on WAVE at the SMART-Highway Test-bed (스마트하이웨이 테스트베드에서의 WAVE 기반 V2X 통신 성능에 대한 실험적 분석)

  • Jung, Han-Gyun;Lim, Ki-Taeg;Shin, Dae-Kyo;Yoon, Sang-Hun;Jin, Seong-Keun;Jang, Soo-Hyun;Shin, Joon-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.4
    • /
    • pp.115-128
    • /
    • 2016
  • Many research activities to reduce accidents on the road and to improve traffic efficiency have been performed and almost research projects are developing technologies and services based on C-ITS technology nowadays. The main concept of C-ITS is improving road safety and traffic efficiency by sharing and reproducing information between various elements. To accomplish this goal, V2X communication technology has been adopted. In Korea, we have studied V2X communication technology in support of SMART-Highway research project and are managing test-bed to verify the developed technology recently. In this paper, we introduce SMART-Highway test-bed and show the procedure and result of V2X communication performance analysis on the test-bed.

The Field Application of Miniature Cone Penetration Test System in Korea (소형콘관입시험(Miniature Cone Penetration Test)의 국내현장 적용)

  • Yoon, Sung-Soo;Ji, Wan-Goo;Kim, Jun-Ou;Kim, Rae-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.349-360
    • /
    • 2009
  • The cone penetration test(CPT) has gained its popularity in site characterization indebted by its reliability, speed, economy, and automatic measurement system since its development in the 1930s. The CPT results, commonly consisting of cone tip resistance, sleeve friction, and pore water pressure measurements, allow us to classify soils as well as to reveal their engineering characteristics. The site condition at which the CPT is allowable is often dependent on the capacity of a CPT system. In Korea, it has been considered that the CPT could be appled only to soft soils in most cases because CPT systems available for stiff soils are very rare due to their expensive procurement and maintenance cost. Luoisiana Transportation Research Center(LTRC) has developed and implemented a field-rugged continuous intrusion miniature cone penetration test(CIMCPT) system since the late 1990s. The miniature cone penetrometer has a sectional cone area of $2cm^2$ allowing system capacity reduction compared to the standard $10cm^2$ cone penetrometer. The continuous intrusion mechanism allows fast and economic site investigation. Samsung Engineering & Construction has recently developed and implemented a similar CIMCPT system based on its original version developed in LTRC. The performance of the Samsung CIMCPT system has been investigated by calibration with the standard CPT system at a well-characterized test site in Pusan, Korea. In addition, scale effect between the miniature cone penetrometer and the standard cone penetrometer has been investigated by comparing the field test results using the both systems.

  • PDF

Mechanical characterization of 100 nm-thick Au thin film using strip bending test (띠 굽힘 시험을 통한 100 nm 두께 금 박막의 기계적 특성 평가)

  • Kim, J.H.;Lee, H.J.;Han, S.W.;Baek, C.W.;Kim, J.M.;Kim, Y.K.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.252-257
    • /
    • 2004
  • Nanometer-sized structures are being applied to many devices including micro/nano electronics, optoelectronics, quantum devices, MEMS/NEMS, biosensors, etc. Especially, the thin film with submicron thickness is a basic structure for fabricating these devices, but its mechanical behaviors are not well understood. The mechanical properties of the thin film are different from those of the bulk structure and are difficult to measure because of its handling inconvenience. Several techniques have been applied to mechanical characterization of the thin film, such as nanoindentation test, micro/nano tensile test, strip bending test, etc. In this study, we focus on the strip bending test because of its high accuracy and moderate specimen preparation efforts, and measure Au thin film, which is a very popular material in micro/nano electronic devices. Au film is deposited on Si substrate by evaporation process, of which thickness is 100nm. Using the strip bending test, we obtain elastic modulus, yield and ultimate tensile strength, and residual stress of Au thin film.

  • PDF

Air Similarity Test for the Evaluation of Aerodynamic Performance of Steam Turbine (스팀터빈의 공력성능 평가를 위한 공기 상사실험)

  • Lim, Byeung-Jun;Lee, Eun-Seok;Yang, Soo-Seok;Lee, Ik-Hyoung;Kim, Young-Sang;Kwon, Gee-Bum
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.5 s.26
    • /
    • pp.29-35
    • /
    • 2004
  • The turbine efficiency is an important factor in power plant, and accurate evaluation of steam turbine performance is the key issue in turbo machinery industry. The difficulty of evaluating the steam turbine performance due to its high steam temperature and pressure environment makes the most steam turbine tests to be replaced by air similarity test. This paper presents how to decide the similarity conditions of the steam turbine test and describes its limitations and assumptions. The test facility was developed and arranged to conduct an air similarity turbine performance test with various inlet pressure, temperature and mass flow rate. The eddy-current type dynamometer measures the turbine-generated shaft power and controls the rotating speed. Pressure ratio of turbine can be controled by back pressure control valve. To verify its test results, uncertainty analysis was performed and relative uncertainty of turbine efficiency was obtained.

ETRI Protocol Test Architecture and Its Application to CCS Network Service Part Protocols (ETRI 프로토콜 검증구조와 CCS망 서비스부 프로토콜에의 응용)

  • Gang, Yeong-Man;Cheon, Dae-Nyeong;Cha, Yeong-Hwan;Baek, Yeong-Sik;Choe, Yang-Hui
    • ETRI Journal
    • /
    • v.10 no.2
    • /
    • pp.3-12
    • /
    • 1988
  • Several ISDN (Integrated Services Digital Network) protocols have implemented at ETRI (Electronics and Telecommunications Research Institute) in an experimental network so that functional characteristics of the protocols under test could be certified against their protocol specifications with the help of the ETRI protocol test facilities. This paper describes ETRI protocol test architecture and its application to testing the NSP (Network Service Part) protocols : MTP (Message Transfer Part) level 3 and SCCP (Signalling Connection Control Part) of the CCITT CCS (Common Channel Signalling ) system No. 7 The test architecture presented here allows tests for two different protocol classes : peer-to-peer and multipeer protocolos. Some extensions are made to the conventional test architectures, namely the test coordination, test result transfer and network state observation method.

  • PDF

Characteristics of Bond Strength with Measuring Methods of Concrete (시험방법에 따른 신ㆍ구 콘크리트의 부착강도 특성)

  • 장흥균;김성환;홍창우;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.597-600
    • /
    • 2003
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials. This study compares the nipple pipe direct tensile test, flexural adhesion test, and core pull-off test with their test results. Substantial differences in the failure stresses of three test methods were attributed to their different geometries and loading conditions. From these comparison and investigation, core pull-off test was relatively good because the coefficient of variation values were about 2%. It would be suitable for use in-situ because of its simplicity and accuracy.

  • PDF