• Title/Summary/Keyword: IT Evaluation

Search Result 30,330, Processing Time 0.067 seconds

A Study on the Development of an Assessment Index for Selecting Start-ups on Balanced Scorecard (균형성과표(BSC) 기반 창업기업 선정평가지표 개발)

  • Jung, kyung Hee;Choi, Dae Soo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.6
    • /
    • pp.49-62
    • /
    • 2018
  • The purpose of this study is to develop an assessment index for the selection of promising start-ups, which will enhance the efficiency of program that support start-ups. In order to develop assessment models for selecting start-ups, three major research steps were conducted. First, this study attempted to theoretically redefine the assessment index from the perspective of the Balanced Scorecard (BSC) through a literature review. Second, major assessment index were derived using Delphi technique for experts in start-up areas. Third, weights were derived by applying AHP technique to calculate the importance of each index. The results of this study are summarized as follows. First, this study attempted to apply the assessment model for selecting start-ups from the Balanced Scorecard (BSC) view through the previous study review. Second, the final major questions were derived with sufficient opinions collected and structured survey of leading start-up experts in areas related to research subjects and elicited the most representative questions. Third, the results of applying the weights of the main selected assessment index, commercialization viewpoint is the most priority, followed by market view, technology development viewpoint, and organizational capability viewpoint. In the middle section, th ability to make products in the commercialization viewpoint, market competitiveness in the market, product discrimination capacity in the technology development perspective, and the ability of the entrepreneur in the organizational capacity perspective were important. Overall important items were found to be in the order of the capabilities of entrepreneurs, market competitiveness, product fire capability, and product discrimination. The importance of small items was highest priority for comparative excellence of competing products, and the degree of marketability, capacity of entrepreneurship, ability to raise capital, desire for entrepreneurship, and passion were shown. The results of this study presented a conceptual alternative to the preceding study on the development of existing selection assessment indexes. And it provides meaningful and important implications as an attempt to develop more sophisticated indicators by overcoming the limitations of empirical research on only some of the evaluation metrics.

Survey of Knowledge on Insomnia for Sleep Clinic Clients (수면클리닉을 방문한 환자들의 불면증에 대한 인식조사)

  • Soh, Minah
    • Sleep Medicine and Psychophysiology
    • /
    • v.26 no.1
    • /
    • pp.23-32
    • /
    • 2019
  • Objectives: Insomnia is not only the most common sleep-related disorder, but also is one of the most important. Knowledge of the comorbidities of insomnia is essential for proper treatment including pharmacological and non-pharmacological methods to prevent disease chronification. This study aimed to determine sleep clinic patients' knowledge of insomnia. Methods: This study recruited 44 patients (24 males and 20 females; mean age $54.11{\pm}16.30years$) from the sleep clinic at National Center for Mental Health. All subjects were asked to complete a self-report questionnaire about their reasons for visiting a sleep clinic and about their knowledge of treatment and comorbidities of insomnia. Results: The reasons for visiting the sleep clinic were insomnia symptoms of daytime sleepiness, irregular sleeping time, nightmares, snoring, and sleep apnea, in that order. Of the responders, 72.7% had a comorbidity of insomnia, and 22.7% showed high-risk alcohol use. In addition, 70.5% of responders chose pharmacological treatment of insomnia as the first option and reported collection of information about treatment of insomnia mainly from the internet and medical staff. More than half (52.3%) of the respondents reported that they had never heard about non-pharmacological treatments of insomnia such as cognitive behavioral treatment (CBT-I) or light therapy. The response rate about comorbidities of varied, with 75% of responders reporting knowledge of the relation between insomnia and depression, but only 38.6% stating awareness of the relation between insomnia and alcohol use disorder. Of the total responders, 68.2% were worried about hypnotics for insomnia treatment, and 70% were concerned about drug dependence. Conclusion: This study showed that patients at a sleep clinic had limited knowledge about insomnia. It is necessary to develop standardized insomnia treatment guidelines and educational handbooks for those suffering from insomnia. In addition, evaluation of alcohol use disorders is essential in the initial assessment of sleep disorders.

Assessment on Accuracy of Stereotactic Body Radiation therapy (SBRT) using VERO (VERO system을 이용한 정위적 체부 방사선치료(SBRT)의 정확성 평가)

  • Lee, Wi Yong;Kim, Hyun Jin;Yun, Na Ri;Hong, Hyo Ji;Kim, Hong Il;Baek, Seung Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • Purpose: The present study aims to assess the level of coherency and the accuracy of Point dose of the Isocenter of VERO, a linear accelerator developed for the purpose of the Stereotactic Body Radiation Therapy(SBRT). Materials and Method: The study was conducted randomly with 10 treatment plans among SBRT patients in Kyungpook National University Chilgok Hospital, using VERO, a linear accelerator between June and December, 2018. In order to assess the equipment's power stability level, we measured the output constancy by using PTW-LinaCheck, an output detector. We also attempted to measure the level of accuracy of the equipment's Laser, kV(Kilo Voltage) imaging System, and MV(Mega Voltage) Beam by using Tofu Phantom(BrainLab, Germany) to assess the accuracy level of geometrical Isocenter. We conducted a comparative analysis to assess the accuracy level of the dose by using an acrylic Phantom($30{\times}30{\times}20cm$), a calibrated ion chamber CC-01(IBA Dosimetry), and an Electrometer(IBA, Dosimetry). Results: The output uniformity of VERO was calculated to be 0.66 %. As for geometrical Isocenter accuracy, we analyzed the error values of ball Isocenter of inner Phantom, and the results showed a maximum of 0.4 mm, a minimum of 0.0 mm, and an average of 0.28 mm on X-axis, and a maximum of -0.4 mm, a minimum of 0.0 mm, and an average of -0.24 mm on Y-axis. A comparison and evaluation of the treatment plan dose with the actual measured dose resulted in a maximum of 0.97 % and a minimum of 0.08 %. Conclusion: The equipment's average output dose was calculated to be 0.66 %, meeting the ${\pm}3%$ tolerance, which was considered as a much uniform fashion. As for the accuracy assessment of the geometric Isocenter, the results met the recommended criteria of ${\pm}1mm$ tolerance, affirming a high level of reproducibility of the patient's posture. The difference between the treatment plan dose and the actual measurement dose was calculated to be 0.52 % on average, significantly less than the 3 % tolerance, confirming that it obtained predicted does. The current study suggested that VERO equipment is suitable for SBRT, and would result in notable therapeutic effect.

Conservation of Removing Surface Contaminants on Silla monument at Jungsung-ri using Nd:YAG Laser Cleaning System (Nd/YAG레이저를 이용한 포항중성리신라비 표면오염물 제거와 보존처리)

  • Lee, Tae Jong;Kim, Sa Dug;Lee, Joo Wan;Oh, Jung Hyeon;Lee, Myeong Seong
    • Korean Journal of Heritage: History & Science
    • /
    • v.44 no.4
    • /
    • pp.142-153
    • /
    • 2011
  • 'Silla Monument Stone in Jungseong-ri, Pohang' was discovered in Pohang City, Gyeongsangbuk Province of Korea in 2009. The monument stone with irregular shape has dimensions of maximum height of 105cm, width of 47.6~49.6cm, thickness of 13.8~14.7cm and weight of 115kg. The results of monument stone was found to be granitite. Conservation treatment procedure was carried out in the order of production of Weathering map, cleaning of surface pollutants, consolidation using ethyl silicate. Black pollutant(crust) that covered more than 60% of the surface was analyzed first in order to remove the pollutants on the surface of the monumental stone by cleaning of surface pollutants using laser. The purpose on analysis was not only to verify the pollutants on the stone but also to carry out preliminary cleaning by securing rocks with same pollutant as the monumental stone. As the results of analysis using p-XRF(PMI. INNOV-X, USA) on the site, high level of Mn and Fe were detected, and the analysis of small section that had been fallen off with SEM/EDX for the purpose of quantitative analysis also detected high level of Mn. The Similar contaminants on Stone secured in the manner described above were made into 10 samples ($5cm{\times}5cm$) and was subjected to preliminary cleaning by Nd-YAG Laser(Laser&Physics, Korea). The results of surface observation through portable microscope during cleaning revealed that the power of 460mJ, wavelength of 1064nm and irradiation frequency of 1,800~2,300 per $25cm^2$ were most effective. Evaluation on the preservative treatment was made through confirmation of the extent of removal through color-difference meter measurement and component analysis prior to and following removal of the pollutants. As the result of color-difference meter measurement increase in the brightness was evidenced by the increase in the brightness ($L^*$)value from 33 to 49, and it was possible to ascertain the reduction in the pollutants as the content of Mn was reduced by about 80% from $50,000{\pm}5,000ppm$ to $10,000{\pm}2,000pmm$ from the result of component analysis.

Evaluation of the usefulness of prone position for reducing the image distortion due to respiration in PET/CT (PET/CT 검사 시 호흡에 따른 영상 왜곡 감소를 위한 엎드린 자세의 유용성 평가)

  • Lee, Han Wool;Kim, Jung Yul;Choi, Yong Hoon;Lim, Han Sang;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose The motion due to respiration of patients undergoing PET/CT is a cause of artifacts in image and registration error between PET and CT images. The degree of displacement and distortion for tumor, which affects the measurement of Standard Uptake Value (SUV) and lesion volume, is especially higher for tumors that is small or located at the base of lungs. The purpose of this study was to evaluate the usefulness of prone position in the correction of image distortion due to respiration of patients in PET/CT. Materials and Methods The imaging equipment used in this study was PET/CT Discovery 600 (GE Healthcare, MI, USA). 20 patients whose lesions were identified in the middle and lower lungs from May to August 2018 were enrolled in this study. After acquiring whole body image in the supine position, additional images of the lesion area were obtained in the prone position with the same conditions. SUVmax, SUVmean, and volume of the lesion were measured for each image, and the displacement of the lesion on PET and CT images were measured, compared, and analyzed. Results The SUVmax, SUVmean, and volume, and displacement of the lesion were $4.72{\pm}2.04$, $3.10{\pm}1.38$, $4.68{\pm}3.20$, and $4.64{\pm}1.88$, respectively for image acquired in the supine position and $5.89{\pm}2.42$, $3.97{\pm}1.65$, $2.13{\pm}1.09$, and $2.24{\pm}0.84$, respectively for image acquired in the prone position, indicating that, for all the lesions imaged, SUVmax and SUVmean were higher and volume and displacement were smaller in the images acquired in prone position compared to those acquired in supine one(p<0.05). Conclusion These results showed that the prone position PET/CT imaging improves the quality of the image by increasing the SUV of the lesion and reducing the respiratory artifacts caused by registration error between PET and CT images. It is considered that the PET/CT imaging in the prone position is helpful in the diagnosis of the disease as an economical and efficient methods that correct registration error for the lesions in basal lung and reduce artifacts.

A Study on the Change of Image Quality According to the Change of Tube Voltage in Computed Tomography Pediatric Chest Examination (전산화단층촬영 소아 흉부검사에서 관전압의 변화에 따른 화질변화에 관한 연구)

  • Kim, Gu;Kim, Gyeong Rip;Sung, Soon Ki;Kwak, Jong Hyeok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.503-508
    • /
    • 2019
  • In short a binary value according to a change in the tube voltage by using one of VOLUME AXIAL MODE of scanning techniques of chest CT image quality evaluation in order to obtain high image and to present the appropriate tube voltage. CT instruments were GE Revolution (GE Healthcare, Wisconsin USA) model and Phantom used Pediatric Whole Body Phantom PBU-70. The test method was examined in Volume Axial mode using the pediatric protocol used in the Y university hospital of mass-produced material. The tube voltage was set to 70kvp, 80kvp, 100kvp, and mAs was set to smart mA-ODM. The mean SNR difference of the heart was $-4.53{\pm}0.26$ at 70 kvp, $-3.34{\pm}0.18$ at 80 kvp, $-1.87{\pm}0.15$ at 100 kvp, and SNR at 70 kvp was about -2.66 higher than 100 kvp and statistically significant (p<0.05) In the Lung SNR mean difference analysis, $-78.20{\pm}4.16$ at 70 kvp, $-79.10{\pm}4.39$ at 80 kvp, $-77.43{\pm}4.72$ at 100 kvp, and SNR at 70 kvp at about -0.77 higher than 100 kvp were statistically significant. (p<0.05). Lung CNR mean difference was $73.67{\pm}3.95$ at 70 kvp, $75.76{\pm}4.25$ at 80 kvp, $75.57{\pm}4.62$ at 100 kvp and 20.9 CNR at 80 kvp higher than 70 kvp and statistically significant (p<0.05) At 100 kvp of tube voltage, the SNR was close to 1 while maintaining the quality of the heart image when 70 kvp and 80 kvp were compared. However, there is no difference in SNR between 70 kvp and 80 kvp, and 70 kvp can be used to reduce the radiation dose. On the other and, CNR showed an approximate value of 1 at 70 kvp. There is no difference between 80 kvp and 100 kvp. Therefore, 80 kvp can reduce the radiation dose by pediatric chest CT. In addition, it is possible to perform a scan with a short scan time of 0.3 seconds in the volume axial mode test, which is useful for pediatric patients who need to move or relax.

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.

Detection Ability of Occlusion Object in Deep Learning Algorithm depending on Image Qualities (영상품질별 학습기반 알고리즘 폐색영역 객체 검출 능력 분석)

  • LEE, Jeong-Min;HAM, Geon-Woo;BAE, Kyoung-Ho;PARK, Hong-Ki
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.82-98
    • /
    • 2019
  • The importance of spatial information is rapidly rising. In particular, 3D spatial information construction and modeling for Real World Objects, such as smart cities and digital twins, has become an important core technology. The constructed 3D spatial information is used in various fields such as land management, landscape analysis, environment and welfare service. Three-dimensional modeling with image has the hig visibility and reality of objects by generating texturing. However, some texturing might have occlusion area inevitably generated due to physical deposits such as roadside trees, adjacent objects, vehicles, banners, etc. at the time of acquiring image Such occlusion area is a major cause of the deterioration of reality and accuracy of the constructed 3D modeling. Various studies have been conducted to solve the occlusion area. Recently the researches of deep learning algorithm have been conducted for detecting and resolving the occlusion area. For deep learning algorithm, sufficient training data is required, and the collected training data quality directly affects the performance and the result of the deep learning. Therefore, this study analyzed the ability of detecting the occlusion area of the image using various image quality to verify the performance and the result of deep learning according to the quality of the learning data. An image containing an object that causes occlusion is generated for each artificial and quantified image quality and applied to the implemented deep learning algorithm. The study found that the image quality for adjusting brightness was lower at 0.56 detection ratio for brighter images and that the image quality for pixel size and artificial noise control decreased rapidly from images adjusted from the main image to the middle level. In the F-measure performance evaluation method, the change in noise-controlled image resolution was the highest at 0.53 points. The ability to detect occlusion zones by image quality will be used as a valuable criterion for actual application of deep learning in the future. In the acquiring image, it is expected to contribute a lot to the practical application of deep learning by providing a certain level of image acquisition.

Evaluation of Disease Resistance of Rice Cultivar Developed in North Korea (북한에서 육성된 벼 품종의 병 저항성 검정)

  • Chung, Hyunjung;Kang, In Jeong;Yang, Jung-Wook;Roh, Jae-Hwan;Shim, Hyeong-Kwon;Heu, Sunggi
    • Research in Plant Disease
    • /
    • v.25 no.3
    • /
    • pp.108-113
    • /
    • 2019
  • Almost 30% of arable lands of North Korea are covered with paddy rice. In rice cultivation of North Korea, rice blast disease is the most important fungal disease and bacterial leaf blight is the most important bacterial disease. Seven North Korean rice cultivars had been tested for the disease resistance against rice blast pathogen, Magnaporthe oryzae and bacterial leaf blight pathogen, Xanthomonas oryzae pv. oryzae. The responses of seven cultivars against 17 different M. oryzae races from South Korea had been quite different. Among seven cultivars, Giljoo1ho was very resistant to all 18 different M. oryzae isolates from South Korea, nevertheless KI or KJ. Pyungdo5ho was very susceptible, it showed susceptible responses to 8 out of 10 KI races and 7 out of 8 KJ races of M. oryzae isolated in South Korea. However, the response to bacterial leaf blight was different from the response to rice blast pathogen. Gijoo1ho, Wonsan69ho, Onpo1ho, and Pyungdo15ho were susceptible to KXO42 (K1) and KXO90 (K2), respectively. Pyungdo5ho was resistant to KXO85 (K1) and KXO19 (K3), and Pyungyang21ho was resistant to K1 races. Based on these results, Giljoo1ho can be a good resource for the breeding of resistant rice cultivar against M. oryzae isolates from South Korea.

Swimming Performance Evaluation of Four Freshwater Fish Species from the South Korea (국내에 서식하는 담수어류 4종에 대한 유영능력 평가)

  • Misheel, Bold;Kim, Kyu-Jin;Min, Kun-Woo;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.2
    • /
    • pp.118-125
    • /
    • 2019
  • Swimming performance of fish is an important factor in the survival of fish. Also, swimming performance of fish is used in the form of habitat, or as a condition to consider when creating a fish ladder. However in Korea, researches in swimming performance of Korean freshwater fish were scarce and inadequate in some part, thus fish ladders were installed without considering their swimming performance. Therefore, in this study, we measured swimming performance of 4 Korean freshwater fish species to consider importance of swimming performance test. The fish used in this study were Carassius auratus, Zacco koreanus, Gnathopogon strigatus, Acheilognathus lanceolata intermedia species which was collected during October to November, 2018 at Geum River, and measurement for swimming speed of each fish was done by using $Loligo^{(R)}$ System, swim tunnel respirometer in January to February of 2019. The average value of the burst critical swimming speed ($U_{crit}$) for each species was $0.8{\pm}0.04m\;s^{-1}$ for C. auratus, $0.77{\pm}0.04m\;s^{-1}$ for Z. koreanus, $0.95{\pm}0.04m\;s^{-1}$ for G. strigatus, $0.73{\pm}0.03m\;s^{-1}$ for A. lanceolata intermedia and the average value of prolonged critical swimming speed was $0.54m\;s^{-1}$ for C. auratus, $0.67m\;s^{-1}$ for Z. koreanus, $0.7m\;s^{-1}$ for G. strigatus, $0.54m\;s^{-1}$ for A. lanceolata intermedia. Since the fish used in this experiment were collected from a small part of the water system in Korea and there were only 4 species, they were not enough to represent the species that inhabit the entire Korean water system. It will be necessary to continue evaluating the swimming performance of other freshwater species in Korea.