• Title/Summary/Keyword: IR Light

Search Result 557, Processing Time 0.028 seconds

A Study on the Biotelemetry using Infra-red Light (적외선을 이용한 생체신호의 원격측정에 관한 연구)

  • Huh, Soo-Jin
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.169-175
    • /
    • 1993
  • Recently, interest in infra-red(IR) telemetry has increased because of the entirely different propagation and reflection properties of IR light as compared to radiowaves. IR hardly penetrates most materials and is reflected from obstacles. An biotelemetry system using these characteristics of indirect transmitted IR lights was developed, in which 3 ECG's are multiplexed and modulated in PDM/PIM pulse sequence. This proto-type system enables us to realize the non-restraint measurement of biological signals. Compared with conventional radio telemetry, this technique has some merits such as no electromagnetic interference, no frequency allocation problem, no government control over transmission power.

  • PDF

Study on the MTTF of Multi Wave Lengths IR and NIR LEDs Module (다파장 IR과 NIR 모듈의 평균 수명 예측에 관한 연구)

  • Kim, Dong Pyo;Kim, Kyung Seob
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.1
    • /
    • pp.44-49
    • /
    • 2021
  • Recently, infrared (IR) and near-infrared (NIR) light-emitting diodes (LEDs) were widely used for home medical applications owing to its low output power and wide exposed area for curing. For deep penetration of the light under the skin, multiple LEDs with wavelengths of 700~10,000 nm were located on a flexible printed circuit board. When multiple wavelengths of LEDs were soldered on a circuit board, the lifetime of LED module highly depends on LEDs with a short lifetime. The mean time to failure (MTTF) was able to calculate with the experimental results under high temperature and the Arrhenius model. The results of this study could help companies to approve the warranty of LED modules and its product.

Automatic FOD Detection Test Using EO/ IR Laser Light Camera (EO / IR Laser Light 카메라를 이용한 FOD 자동탐지 시험)

  • Shin, Hyun-Sung;Hong, Gyo-Young;Hong, Jae-Beom;Choi, Young-Soo;Kim, Yun-Seob
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.638-642
    • /
    • 2017
  • FOD is a generic term for substances with potential threats that can pose a fatal risk to aircraft. Therefore, FOD should be noted in all areas of the airport. Especially, the method of detecting and collecting FOD in runway and aircraft movements is very low efficiency and economical efficiency of airport operation, so it is essential to develop FOD automatic detection system suitable for domestic environment. As part of the aviation safety technology development project, the development of an automatic detection system for foreign matter in the moving area of the aircraft inside the airport is underway. In this paper, it is confirmed that EO / IR camera is used for detection of foreign objects at Taean Airfield of Hanseo University. EO camera is used during the day and IR camera is used at night.

Analysis of suppressed thermal conductivity using multiple nanoparticle layers (다중층 나노구조체를 통한 열차단 특성 제어)

  • Tae Ho Noh;Ee Le Shim
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.4
    • /
    • pp.233-242
    • /
    • 2023
  • In recent years, energy-management studies in buildings have proven useful for energy savings. Typically, during heating and cooling, the energy from a given building is lost through its windows. Generally, to block the entry of ultraviolet (UV) and infrared (IR) rays, thin films of deposited metals or metal oxides are used, and the blocking of UV and IR rays by these thin films depends on the materials deposited on them. Therefore, by controlling the thicknesses and densities of the thin films, improving the transmittance of visible light and the blocking of heat rays such as UV and IR may be possible. Such improvements can be realized not only by changing the two-dimensional thin films but also by altering the zero-dimensional (0-D) nanostructures deposited on the films. In this study, 0-D nanoparticles were synthesized using a sol -gel procedure. The synthesized nanoparticles were deposited as deep coatings on polymer and glass substrates. Through spectral analysis in the UV-visible (vis) region, thin-film layers of deposited zinc oxide nanoparticles blocked >95 % of UV rays. For high transmittance in the visible-light region and low transmittance in the IR and UV regions, hybrid multiple layers of silica nanoparticles, zinc oxide particles, and fluorine-doped tin oxide nanoparticles were formed on glass and polymer substrates. Spectrophotometry in the UV-vis-near-IR regions revealed that the substrates prevented heat loss well. The glass and polymer substrates achieved transmittance values of 80 % in the visible-light region, 50 % to 60 % in the IR region, and 90 % in the UV region.

Efficient Filtering for Depth Sensors under Infrared Light Emitting Sources (적외선 방출 조명 조건 하에서 깊이 센서의 효율적인 필터링)

  • Park, Tae-Jung
    • Journal of Digital Contents Society
    • /
    • v.13 no.3
    • /
    • pp.271-278
    • /
    • 2012
  • Recently, infrared (IR)-based depth sensors have proliferated as consumer electronics thanks to decreased price, which led to various applications including gesture recognition in television virtual studios. However, the depth sensors fail to capture depth information correctly under strong light conditions emitting infrared light which are very common in television studios. This paper analyzes the mechanism of such interference between the depth sensors relying on certain IR frequencies and infrared light emitting sources, and provides methods to get correct depth information by applying filters. Also, it describes experiment methods and presents the results of applying multiple combinations of filters with different cut-off frequencies. Finally, it proves that the interference due to IR can be filtered out using proposed filtering method practically by experiment.

The characteristics of the electroluminescent devices using Ir$(ppy)_3$ (Ir$(ppy)_3$를 발광물질로 이용한 EL소자의 특성분석)

  • Kim, Jun-Ho;Kim, Yun-Myoung;Ha, Yun-Kyoung;Kim, Young-Kwan;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.437-439
    • /
    • 2000
  • The internal quantum efficiency of EL devices using fluorescent organic materials is limited within 25% because of the triplet excitons which can hardly emit light. So there has been considerable interest in finding ways to obtain light emission from triplet excitons. One approach has been to add phosphorescent compounds to one of the layers in an EL device. Then triplet excitons can transfer to these phosphorescent molecules and emit light. In this study, multilayer organic light-emitting devices with phosphorescent emitter, tris (2-phenylpyridine)iridium ($Ir(ppy)_3$) were prepared. The device exhibited power luminous efficiency of 1.07 1m/W at the luminance of $61.6\;cd/m^2$ diriven at the voltage of 9 V and current density of $1.9mA/cm^2$. At the luminance of $100\;cd/m^2$, the luminous efficiency was obtained 1.05 lm/W with the voltage of 9.5 V and the corrent density of $2.8\;mA/cm^2$.

  • PDF

Comparison of the degree of conversion of light-cured resin cement in regard to porcelain laminate thickness, light source and curing time using FT-IR (도재 라미네이트 두께와 광원 및 광조사 시간에 따른 광중합형 레진 시멘트의 FT-IR을 이용한 중합도 비교)

  • Yuh, Chi-Sung;Kim, Jee-Hwan;Kim, Sun-Jai;Lee, Yong-Keun;Shim, June-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.416-423
    • /
    • 2009
  • Statement of problem: The degree of light attenuation at the time of cementation of the PLV restoration depends on characteristics such as thickness, opacity and shade of the restorations, which interfere with light transmittance and, as a result, may decrease the total energy reaching the luting cement. Purpose: The purpose of this study was to compare the degree of conversion of light-cured resin cements measuring by FT-IR in regard to different thickness, light devices and curing time. Material and methods: In the control group, a clear slide glass (1.0 mm) was positioned between the light cured resin cement and light source. The specimens of ceramics were made with IPS Empress Esthetic. The ceramics were fabricated with varying thicknesses-0.5, 1.0, 1.5 mm with shade ETC1. Rely $X^{TM}$ Veneer with shade A3, light-cured resin cement, was used. Light-activation was conducted through the ceramic using a quartz tungsten halogen curing unit, a light emitting diode curing unit and a plasma arc curing unit. The degree of conversion of the light-cured resin cement was evaluated using FT-IR and OMNIC. One-way ANOVA and Tukey HSD test were used for statistical analysis ($\alpha$< .05). Results: The degree of conversion (DC) of photopolymerization using QTH and LED was higher than results of using PAC in the control group. After polymerization using QTH and LED, the DC results from the different ceramic thickness- 0.5 mm, 1.0 mm, 1.5 mm- did not show a significant difference when compared with those of control group. However, the DC for polymerization using PAC in the 1.5mm ceramic group showed significantly lower DC than those of the control group and 0.5 mm ceramic group (P<.05). At 80s and 160s, the DC of light-cured resin cement beneath 1.0 mm ceramic using LED was significantly higher than at 20s (P<.05). Conclusion: Within the limitation of this study, when adhering PLV to porcelain with a thickness between 0.5-1.5 mm, the use of PAC curing units were not considered however, light cured resin cements were effective when cured for over 40 seconds with QTH or LED curing units. Also, when curing the light cured resin cements with LED, the degree of polymerization was not proportional with the curing time. Curing exceeding a certain curing time, did not significantly affect the degree of polymerization.

DEVELOPMENT OF A CRYOGENIC TESTING SYSTEM FOR MID-INFRARED DETECTORS ON SPICA

  • Nishiyama, Miho;Kaneda, Hidehiro;Ishihara, Daisuke;Oseki, Shinji;Takeuchi, Nami;Nagayama, Takahiro;Wada, Takehiko
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.355-357
    • /
    • 2017
  • For future space IR missions, such as SPICA, it is crucial to establish an experimental method for evaluating the performance of mid-IR detectors. In particular, the wavelength dependence of the sensitivity is important but difficult to be measured properly. We are now preparing a testing system for mid-IR Si:As/Si:Sb detectors on SPICA. We have designed a cryogenic optical system in which IR signal light from a pinhole is collimated, passed through an optical filter, and focused onto a detector. With this system, we can measure the photoresponse of the detector for various IR light using optical filters with different wavelength properties. We have fabricated aluminum mirrors which are adopted to minimize thermal distortion effects and evaluated the surface figure errors. The total wavefront error of the optical system is $1.3{\mu}m$ RMS, which is small enough for the target wavelengths ($20-37{\mu}m$) of SPICA. The point spread function measured at a room temperature is consistent with that predicted by the simulation. We report the optical performance of the system at cryogenic temperatures.

A Research on Middle School Teachers and Students Awareness and Understanding of Analysis for the Light (중학교 과학 교사와 학생들의 빛에 대한 인식과 이해 정도 분석)

  • Kim, Minyoung;Han, Shin;Park, Taeyoon
    • Journal of the Korean Society of Earth Science Education
    • /
    • v.8 no.3
    • /
    • pp.267-280
    • /
    • 2015
  • The purpose of this study is to identify the conceptions of middle school students and teachers about Visible-Light, Ultra-Violet(UV) and Infrared-Ray(IR). We administered questionnaire 3 teacher and 102 students(48 people of middle school 2nd students and 54 people of middle school 3rd students) who learned by 3 teachers in seoul. From the analysis, it was found that many students and teachers didn't understand the basic principle of UV and IR. Significant number of students belive that it is possible to see objects the absence of visible light. Most students belive that they can see objects in the presence of UV light alone. They think that "Light" is single concept. Teachers were generally more aware of the origin and explanation of UV. But teachers expressed some uncertainties. They tend to think negative effect for UV.

Fabrication of Silicon Window for Low-price Thermal Imaging System (저가형 열영상 시스템을 위한 실리콘 윈도우 제작)

  • Sung, Byung Mok;Jung, Dong Geon;Bang, Soon Jae;Baek, Sun Min;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.264-269
    • /
    • 2015
  • An infrared (IR) bolometer measures the change of resistance by absorbing incident IR radiation and generates a signal as a function of the radiation intensity. Since a bolometer requires temperature stabilization and light filtering except for the infrared rays, it is essential for the device to be packaged meeting conditions that above mentioned. Minimization of heat loss is needed in order to stabilize temperature of bolometer. Heat loss by conduction or convection requires a medium, so the heat loss will be minimized if the medium is a vacuum. Therefore, vacuum packaging for bolometer is necessary. Another important element in bolometer packaging is germanium (Ge) window, which transmits IR radiation to heat the bolometer. To ensure a complete transmittance of IR light, anti-reflection (AR) coatings are deposited on both sides of the window. Although the transmittance of Ge window is high for IR rays, it is difficult to use frequently in low-price IR bolometer because of its high price. In this paper, we fabricated IR window by utilizing silicon (Si) substrate instead of Ge in order to reduce the cost of bolometer packaging. To enhance the IR transmittance through Si substrate, it is textured using Reactive Ion Etching (RIE). The texturing process of Si substrate is performed along with the change of experimental conditions such as gas ratio, pressure, etching time and RF power.