• Title/Summary/Keyword: IPM

Search Result 410, Processing Time 0.029 seconds

A Fault Operation of the IPM Due to the Effect of Miller Capacitance and its Solution (밀러 커패시턴스의 영양에 의한 IPM의 오동작과 대책)

  • 조수억;강필순;김철우
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.83-88
    • /
    • 2003
  • This paper analyses a fault operation due to the effect of miller capacitance, which severely influences the performance of the IPMs based on computer-aided simulations, and also it presents a good solution to solve that problem. A miller capacitance existed between gate and collect is very closely related to the stray capacitance formed between gate and emitter, and the value of gate resistor. These relationships are proved by the computer-aided simulation. Based on the PSpice simulation results, a customized IPM employing an auxiliary circuit is presented to minimize a fault operation. And it is compared to the standard IPM by the experimental waveform. As a result, it is verified that a customized IPM has a voltage margin to prevent a fault operation approx. 3 [V].

An IPM(Intelligent Power Module) performance evaluation system for the driving of a multi-pole BLDC motor (다극 BLDC 전동기 구동을 위한 IPM(Intelligent Power Module) 성능 평가 시스템)

  • Min, Bung-kil;Kunn, Young;Hwang, Min-kyu;Choi, Jung-keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.686-689
    • /
    • 2014
  • This Paper is about the study that use the IPM(Intelligent Power Module) which is a integrated switching module to drive inverter gates for driving of a multi-pole BLDC(Brushless Direct Current) motors. When designing a inverter using the various manufacturers IPM, it suggests a electronic circuit system to evaluate the electrical and logical characteristics of the IPM with various brands.

  • PDF

Optimal System Design and Minimization of Conducted EMI Noise in Elevator Inverter System by Customized IPM (주문형 IPM을 이용한 엘리베이터용 인버터의 최적화 설계 및 전도 EMI 노이즈 저감)

  • 조수억;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.313-320
    • /
    • 2003
  • This paper deals with the optimal design of a elevator inverter system based on the customized IPM. The proposed method reduces dv/dt and di/dt, which resulted in the minimized conducted EMI noise without an additional circuitry. It only optimizes the value of gate resistor in the IGBT embedded in the IPM. In order to optimize the customized IPM to a elevator system, we simulated and measured the spike voltage and the motor surge voltage including the temperature variation due to the switching losses at the IPM case and heat-sink. As a result, thanks to the optimized value of the gate resister in the IPM, the conducted EMI noise is reduced approx. 5∼10 [dB$\mu$V] in a particular frequency domain.

Development of IPM(Intelligent Power Module) IGBT switch performance evaluation system for the driving of the A.C. motor (교류 전동기 구동을 위한 IPM(Intelligent Power Module) IGBT 스위치 성능 분석 방법 개발)

  • Choi, Jung-Keyng
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.4
    • /
    • pp.291-297
    • /
    • 2022
  • This Paper is about the study that design performance and reliability measurement circuits of the IPM which is an intelligent switching switch module included at an inverter circuits for driving of A.C. Servo motors in home appliance. IPM is a core device of motor driver and it's switching characteristics should be retained uniformly during the driving of a servo system. All of it's specification, the collector emitter switch on voltage Vce(on) spec. is very important. As the IPM are core part of inverters and producing from several brands and versions, for optimal performances of application systems a method and measurement & evaluation system to measure Vce(on) value, collector emitter switch on voltage, of the IPM IGBT switches with various brands are required. Especially, the proposed method can measure and evaluate Vce(on) values of IPM with load at mounting state on the motor driving circuits and proposed measurement & evaluation system can be important instrument systems for IPM user companies.

A Comparison Study on Demagnetization Characteristics of IPM Synchronous Motor (IPM 동기모터의 불가역감자 특성 비교 연구)

  • Jung, Seok-Won;Kwon, Hyuk-Sung;Jung, Hyun-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.839-840
    • /
    • 2015
  • IPM(Interior Permanent Magnet) 모터는 마그네틱 토크와 릴럭턴스 토크를 이용하는 모터이다. 이런 IPM 모터에 쓰이는 영구 자석 중 희토류 자석은 온도에 취약한 특성이 있어 낮은 온도에 비해 높은 온도에서 더 쉽게 불가역감자가 발생할 수 있다. 또한 페라이트자석에 비해 상대적으로 가격이 비싸 희토류 저감 IPM 모터 개발이 지속적으로 진행되고 있다. 따라서 본 논문에서는 희토류 저감 IPM 동기모터의 영구자석 위치를 변화한 3가지 U자형 2층 IPM 모터 모델을 선정하여 회전자 전류의 크기 및 위상 그리고 약자속 제어를 고려한 불가역 감자 특성을 비교 및 분석하였다. 이렇게 분석한 결과를 바탕으로 IPM 설계 시 불가역감자에 강인한 설계 방법에 대하여 고찰하였다.

  • PDF

Growth, Lodging Reduction as Affected by Iprobenfos-metconazole(IPM) in Direct-seeded Rice on Flooded Paddy Field (벼 담수직파재배시 Iprobenfos-metconazole(IPM) 처리에 따른 생육과 도복경감효과)

  • Lee, Kyehwan;Choi, Bongsu;Park, Jonghyun;Woo, Sunhee;Lee, Chulwon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.4
    • /
    • pp.393-398
    • /
    • 2013
  • Lodging in the direct seeded rice cultivation on flooded paddy is being severe problem due to the lower production and grain quality at ripening stage. This study was conducted to examine the effect of Iprobenfos-metconazole (IPM) treated 50, 40 and 30 days before heading respectively as a plant regulator to reduce the lodging at ripening stage of direct seeding rice cultivation. The culm length treated with IPM, especially the 4th culm internode, was shortened more than with untreated plot, and the most effective time was at 30 days before heading. At 20 days after heading the flag leaves colour showed more greening than in the untreated leaves and the plot with IPM treatment was to be maintained longer compared to the control plot. The Nitrogen concentration of leaves with IPM was lower than in the control plot, and $SiO_2$ contents were higher than in the untreated plot and $SiO_2/N$ ratio was increased more in the IPM plot than in the control plot. The breaking strength of 3rd and 4th culm internode with IPM treatment was higher than in the untreated plot, and the lodging index was reduced in the IPM plot significantly and the field lodging also was reduced. As the results the rice production in the IPM plot was increased more due to be higher ripening ratio and seed grain weight compared to the untreated plot to be occurred the field lodging.

Development of Enhanced Interleaved PFC Boost Converter typed 650V Intelligent Power Module for up to 10kW HVAC Systems (10kW급 HVAC 시스템을 위한 Enhanced Interleaved PFC Boost 컨버터 형태의 650V IPM 개발)

  • Lee, Kihyun;Hong, Seunghyun;Kim, Taehyun;Jeong, Jinyong;Kwon, Taesung
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.536-538
    • /
    • 2018
  • This paper introduces an enhanced interleaved (IL) PFC (Power Factor Correction) boost converter typed 650V Intelligent Power Module (IPM), which is fully optimized hybrid IGBT converter modules; Silicon (Si) IGBT and Silicon Carbide (SiC) diode, for up to 10kW HVAC (Heating, Ventilation, and Air Conditioning) systems. It utilizes newly developed $4^{th}$ Generation Field Stop (FS) trench IGBTs, $EXTREMEFAST^{TM}$ anti-paralleled diodes, SiC Junction Barrier Schottky (JBS) diodes, Bridge rectifiers, Multi-function LVIC, and Built-in thermistor provide good reliable characteristics for the entire system. This module also takes technical advantage of DBC (Direct Bonded Copper) substrate for the better thermal performance. It is shown that the Si IGBT/SiC diode hybrid IL PFC module can achieve excellent EMI performance and greatly enhance the power handling capability or switching frequency of various applications compared to the Si IGBT/Diode. This paper provides an overall description of the newly developed 650V/50A Hybrid SiC IL PFC IPM product.

  • PDF

Reducing the Cogging toque of IPM type BLDC Motor according to the Flux barrier shape (IPM type BLDC 전동기의 자속장벽 설치에 따른 코깅 토크 저감)

  • Yang, Byoung-Yull;Yun, Keun-Young;Kwon, Byung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.67-69
    • /
    • 2004
  • This paper describes an approach to design a interior permanent magnet motor(IPM motor) for the reduction of cogging torque. The magnitude of the torque ripple and cogging torque in a interior permanent magnet motor(IPM motor) are generally dependent on several major factors: the shape of stator tooth tip, slot opening width, air gap length, the shape of barrier preventing flux leakage of magnets, magnet configuration and magnetization distribution or magnet poles. In this paper, the IPM BLDC motor is designed considering a saturated leakag flux between the barriers on the rotor for increasing the efficiency and decreasing the magnitude of the cogging torque. Analytical model is developed for the IPM BLDC motor with a concentrated winding stator. The results verifies that the proposed design approach is very efficient and effective in reducing the cogging torque and the torque ripple of the IPM BLDC motor to be used in an electric vehicle.

  • PDF

Evaluation of EDTA-based Three Methods to Detect IMP-1 and VIM-2 Type Metallo-${\beta}$-Lactamase-Producing Clinical Isolates of Imipenem Resistant Acinetobacter and Pseudomonas spp.

  • Hong, Seung-Bok;Shin, Kyung-A;Hwang, Seock-Yeon
    • Biomedical Science Letters
    • /
    • v.17 no.2
    • /
    • pp.135-140
    • /
    • 2011
  • We compared three EDTA-based phenotypic screening methods for detecting IMP-1 and VIM-2 type metallo-${\beta}$- lactamase (MBL)-producing isolates of Acinetobacter and Pseudomonas spp., EDTA-double disk synergy test (EDTADDST), Etest MBL, and imipenem (IPM)-EDTA disk test. A total of 183 isolates (65 Acinetobacter spp. and 118 Pseudomonas spp. showing IPM resistance), confirmed to MBL genes by PCR, were used. The criteria for MBL production were (i) presence of a synergistic zone between IPM and EDTA disks in EDTA-DDST, (ii) reduction of IPM minimal inhibitory concentration by ${\geq}$ 3 twofold dilutions in the presence of EDTA in the Etest MBL, and (iii) ${\geq}$ 7 mm increase in the inhibition zone around the IPM plus EDTA disks compared with a sole IPM disk in the IPM-EDTA disk test. In this study using 87 MBL-producing and 96 MBL-nonproducing isolates, the sensitivities/specificities of EDTA-DDST, Etest MBL and IPM-EDTA disk tests were 94.3/78.1%, 89.7/91.7%, and 97.7/95.8%, respectively. When the threshold for the increase of the inhibition zone around the IPM plus EDTA disk over a sole IPM disk was altered to ${\geq}$ 5 mm and ${\geq}$ 8 mm for Acinetobacter spp. and Pseudomonas spp., respectively, the sensitivity and specificity of the test were 98.9% and 96.9%, respectively. Of the three EDTA-based phenotypic tests, the IMP-EDTA disk test was superior for detection of MBL-producing isolates.

Comparison of in Vivo Antibacterial Activities and Pharmacokinetics of New Carbapenem Derivatives, CRB 529 and CRB 550, in Mice and Rats (신규 Carbapenem 유도체 CRB 529 및 CRB 550의 생체내 항균효과와 약물동태의 비교)

  • 김준겸;민관기;이주몽;이홍우;김정우
    • YAKHAK HOEJI
    • /
    • v.39 no.4
    • /
    • pp.360-366
    • /
    • 1995
  • 1-$\beta$-Methyl carbapenem-2-substituted pyrroudine derivatives. CRB 529 and CRB 550, were synthesized as investigational carbapenem derivatives. It has been reported that the in vitro antibacterial activities of the compounds against G(+) and G(-) bacteria were almost the same or more effective than those of imipenem (IPM) and meropenem (MEPM), and also showed better in vivo efficacy than MEPM and inlipeneni/cilastatin (IPM/CS) against representative G(-) organisms, P. aeruginosa and MRSA organisms, S. aureus. The antibacterial activities, pharmacokinetics and protective efficacy of IPM/CS and CRB 529 and CRB 550 wereconducted after subcutaneous or intravenous administration to mice and rats. The pharmacokinetic parameters of CRB 529 and CRB 550 in mice were as follows: the observed maximal serum concentrations (C$_{max}$) following I.V. administration were 87.5 and 101 $\mu\textrm{g}$/ml for CRB 529 and CRB 550, respectively, and 63.6 $\mu\textrm{g}$/ml for IPM/CS. The half-lives (t$_{1/2}$) were 14.0 and 12.0 n-dn for CRB 529 and CRB 550, respectively, and 14.8 min for IPM/CS. In rats, $C_{max}$ after I.V. administration were 74.0 and 91.8 $\mu\textrm{g}$/ml for CRB 529 and CRB 550, respectively, and 41.2 $\mu\textrm{g}$/ml for IPM/CS. The tissue levels of CRB 529 and CRB 550 and IPM/CS after I.V. administration at a dose of 20 mg/kg decreased by the following order: lung, heart, kindney, liver and spleen for CRB 529, lddney, liver. lung, heart and spleen for CRB 550 and kidney, lung, liver, heart, spleen and brain for IPM/CS. In systemic infection, CRB 529 and CRB 550 showed excellent efficacies against P. aeruginosa and S. aureus (MRSA) at a dose of 5 mg/kg. The PD$_{50s}$ were 0.80, 0.36 mg/kg for CRB 529 and CRB 550, respectively, and 3.22 mg/kg for IPM/CS against P. aeruginosa. The corresponding values against S. aureus (MRSA) were 76.0, 55.3 mg/kg for CRB 529 and CRB 550, respectively, and 146 mg/kg for IPM/CS. In local infection, the antibacterial activities of CRB 529 and CRB 550 were more effective than those of IPM/CS against intrarenal infection with E. coli and P. aeruginosa and also showed as effective as IPM/CS against respiratory tract infection with E. coli and P. aeruginosa at a dose of 5 mg/kg.

  • PDF