• Title/Summary/Keyword: IPL

Search Result 56, Processing Time 0.024 seconds

The Effects of an Aerobics on the Auditory Evoked Potential (에어로빅스가 청각유발전위에 미치는 영향)

  • Park, Sang-Nam;Kim, Young-Hwal;Kim, Byung-Weon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.224-230
    • /
    • 2006
  • Up to now, there have been rare clinical studies on leaders and aerobics athletes. To get the useful data for protecting from auditory disorder, we selected 15 female aerobics leaders (experimental group) and 15 females (control group) unexperienced in aerobics and a without neurological and octolaryngological disorder. The average age was $34.87{\pm}8.80$ (experimental group) and $34.07{\pm}8.45$ (control group) years, and the average career of an aerobics leader (experimental group) was $8.33{\pm}4.73$ years. We measured the auditory evoked potential (AEP) of the two groups treated with 70, 75 and 85 dB intensity from January 2006 to May 2006 and analyzed the absolute latency (AL) and interpeak latency (IPL) by the SPSS/pc+ 12.0 program. In the comparison of the AL between the experimental group and the control group according to intensity, both ears treated with 70 and 75 dB had a significant difference (p<0.05) in the I, III, V wave and in the I, V wave respectively, and the experimental group treated with 85 dB showed a difference in the I, III, V wave (left ear) and in the I wave (right ear) respectively. The IPL of the two groups treated with various intensities had no prolongation. In the comparison of the AL between the experimental group and the control group according to ages, the experimental group in their 20s treated with 70 dB showed a significant difference (p<0.05) in the V wave (left ear) and in the I, III, V wave (right ear), and the experimental group in their 20s treated with 75 dB in the I, III wave (left ear) and in I, III, V wave (right ear), and experimental group in their 20s treated with 85 dB in the V wave (left ear) and in the III, V wave (right ear). The experimental group in their 30s treated with 70 dB had a significant difference (p<0.05) only in the V wave (right ear). Only in the IPL of subjects in their 20s treated with 85 dB, III-V and I-V of both ears was extended. In the comparison of the AL and IPL according to career, there was no significant difference between the two groups. From this results, we concluded that the lower sound intensity (70 dB) showed a more significant difference in the experimental group than the control group. We concluded that the leader of aerobics exposed to louder sounds than normal people are affected by auditory neurological and octolaryngological disorders. So we think that the leaders of aerobics need to control the noise level for protecting themselves against a disease.

  • PDF

Sterilization of Rapeseed Sprouts by Intense Pulsed Light Treatment (고강도 광원을 이용한 새싹 채소의 살균)

  • Park, Heeran;Cha, Gyung-Hee;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.1
    • /
    • pp.36-41
    • /
    • 2016
  • In this study, the effects of intense pulsed light (IPL) treatment on microbial inactivation and quality in rapeseed sprouts were investigated. Untreated rapeseed sprouts exhibit a high level of total aerobic bacteria (TAB) ($1.2{\times}10^7CFU/g$), coliform bacteria (coliform) ($3.3{\times}10^6CFU/g$), and pathogenic E. coli (PE) ($2.1{\times}10^5CFU/g$). The microorganisms found on rapeseed sprouts decreased with exposure to increasing light intensity and treatment time. The greatest reduction in microbial content was observed with a treatment of 1000 V, 5 pps for 10 min, where TAB, coliform, and PE levels decreased to 1.0 log CFU/g, 1.6 log CFU/g, and 1.8 log CFU/g, respectively. In agreement with these data, the microbial inactivation rate increased with the increase in the distance between the light source and the samples during IPL treatment. After IPL treatment of rapeseed sprouts, water content and vitamin C content decreased.

Development of the High Voltage Converter for the Pulsed Light Sterilization (광펄스 살균을 위한 다채널 고전압 컨버터의 개발)

  • Lee, Young-Woo;Kim, Hyung-Won;Choi, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.29-37
    • /
    • 2012
  • As the demand for the fresh non-thermal food is increased, it is required to develop the fast and perfect sterilization method. The conventional sterilization method using ultraviolet lamp has some disadvantages such as imperfect sterilization and longer process time. In this research, IPL(Intense Pulsed Light) sterilization system is introduced to overcome the drawbacks of the conventional system, and suitable power supply architecture for the system is discussed. Since the IPL sterilization system uses Zenon lamps which requires the 600~2,100[V] for the lightning and 16~30[kV] for the trigger, the converter for the system should be able to generate the high voltage and to discharge the large amount of energy instantaneously. In this research a new power system architecture which has a modified forward converter topology with two switches for generating high voltage and a capacitor bank to control the energy for the lightning by switching is introduced.

Establishment of the Appropriate Risk Standard through the Risk Assessment of Accident Scenario (사고시나리오별 위험도 산정을 통한 적정 위험도 기준 설정)

  • Kim, Kun-Ho;Chun, Young-Woo;Hwang, Yong-Woo;Lee, Ik-Mo;Kwak, In-ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • An off-site consequence analysis is used to calculate the risks when hazardous chemicals that is being used on-site has been exposed off-site; the biggest factor that impacts the risk is the risks of accident scenarios. This study seeks to calculate risks according to accident scenarios by applying OGP/LOPA risk calculating methods for similar facilities, calculate risk reduction ratio by inspecting applicable IPL for incidents, and propose an appropriate risk standard for different risk calculating methods. Considering all applicable IPL when estimating the safety improvement of accident scenarios, the risk of OGP is 8.05E-04 and the risk of LOPA is 1.00E-04, According to the case of IPL, the risk is 1.34E-02. The optimal risk level for accident scenarios using LOPA was $10^{-2}$, but the appropriate risk criteria for accident scenarios in foreign similar studies were $10^{-3}{\sim}10^{-4}$, the risk of a scenario can be determined at an unacceptable level. When OGP is applied, it is analyzed as acceptable level, but in case of applying LOPA, all applicable IPL should be applied in order to satisfy the acceptable risk level. Compared to OGP, the risk is high when LOPA is applied. Therefore, the acceptable risk level should be set differently for each risk method.

Flavor and taste characteristic of black pepper by different nonthermal sterilization methods (비가열 살균 후추의 향미특성)

  • Lee, Gwang Min;Shin, Jung Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.6
    • /
    • pp.551-557
    • /
    • 2019
  • The purpose of this study was to investigate the changes of flavor and taste characteristics of black pepper treated with three different nonthermal sterilization methods, which are intense pulsed light (IPL), ultraviolet (UV), and cold plasma (CP). Also, the sensorial and instrumental evaluation of black pepper before and after nonthermal treatments were analyzed. As a result of color value, UV and CP treatments did not show chromacity difference (ΔE), but IPL treatment showed a significant difference of 6.58. Piperine contents of sample before nonthermal treatments was 10.7±0.53 mg/g and the piperine contents of all samples decreased after nonthermal treatments. The result of the electronic nose analysis were divided into two groups before and after nonthermal treatments, and divided into three group by principle component analysis. According to the intensity test, after nonthermal treatments, all sample had low flavor and taste, and the intensity was in the order of IPL, CP, and UV. In thirteen sensory attribute languages developed through quantitiative descriptive analysis (QDA), the intensity value of the samples were low after nonthermal treatments.

Construction of Internet Public Library Asia (아시아 인터넷 공공 도서관(Internet Public Library Asia) 구축에 관한 연구)

  • 이원숙;일본명;일본명;일본명;일본명
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.13 no.2
    • /
    • pp.59-73
    • /
    • 2002
  • Libraries, not only research libraries but also public libraries, have been fundamentally affected by the immense spread of the Internet and the World Wide Web. Many public libraries have their Web pages, through which they are providing their new and conventional services. There are also web sites which provide library-like services. This paper shows an experimental project named Internet Public Library Asia, which provides information in multiple languages of information resources published in Chinese, Japanese and Korean languages. This paper firstly overviews how traditional public libraries have been affected by the Internet. Then, it describes a few aspects from the viewpoint of crucial library function on the Internet and also from the viewpoint of Asian resources and users. This paper secondly proposes a model to serve information about valuable resources published in multiple Asian languages, and then shows the metadata schema and a few software tools developed for IPL-Asia The name of IPL is borrowed from Internet Public Library based at University of Michigan, since it is, in part, a collaborative activity with the IPL in Michigan. The metadata schema is defined based both on Dublin Core and IEEE LOM and adapted for parallel description in the four languages, i. e. , Chinese, Japanese, Korean and English. The software tools provide functions to support collaboration among people engaged in development of metadata database and metadata editing. These tools have been developed based on the XML technologies.

  • PDF

Contamination level of commercialized pepper and sterilization effect by intense pulsed light in batch system (시중 판매 후추의 오염도 및 회분식 광펄스 처리에 의한 살균 효과)

  • Park, Jihyun;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.48 no.5
    • /
    • pp.525-529
    • /
    • 2016
  • Twenty-nine pepper products commercially available in the market were collected and investigate for contamination levels. Pepper products purchased from traditional markets had a degree of contamination of $10^6-10^7CFU/g$ aerobic bacteria, $10^4-10^5CFU/g$ Bacillus sp., and less than $10^2CFU/g$ yeast and molds. Organic pepper showed a degree of contamination of $10^4$ aerobic bacteria, $10^2-10^3$ Bacillus sp., and less than $10^1$ yeast and molds. Intense pulsed light (IPL) treatment of 10 min (1,000 V, 5 pps and 4 cm sample-to-lamp distance) showed a bacterial death rate of 1.45-1.55 log for whole peppers, and of 0.8-0.85 log for black and white pepper powder. The sterilization rate using IPL was higher than that using other non-thermal sterilization methods, such as ozone treatment or low-pressure discharge plasma sterilization, indicating that the IPL sterilization method may find potential application in the industry. However, further studies may need to be conducted to enhance the effect of sterilization.

A Study on the Control of Hygroscopicity and Hardness in Polymer Surfaces (고분자 표면의 흡습성 및 경도 제어 연구)

  • Jinil Kim;Young Nam Jung;Doa Kim;Myung Yung Jeong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.4
    • /
    • pp.86-90
    • /
    • 2023
  • The packaging of electronic devices performs a protective function to ensure that their durability and reliability are not affected by changes in the operating environment caused by external factors. Recent advances in materials have led to ongoing research into bonded packaging of heterogeneous materials such as polymers and inorganic materials in electronic devices. In this packaging process, it is important to have a binding that joins the materials and ensures the operating environment, which includes adhesion to the substrate, corrosion and oxidation resistance through moisture removal, and durability. In this study, the hygroscopicity of the coating layer by modifying the polymer surface based on PVA was evaluated by controlling and measuring the contact angle, and the adhesion was confirmed by applying water-based ink and testing according to ASTM_D3363. For the durability of the polymer surface, the IPL post-treatment process was used to improve the hardness and toughness against applied voltage, and the pencil hardness test and nanoindentation test were conducted. Through this, we analyzed and proposed solutions to ensure the reliability and durability of polymer devices in polymer microfabrication against environmental factors such as moisture, temperature fluctuations and adhesion, and surface abrasion.

The Study on the Collection Analysis for an International Cooperative Network of Knowledge-Information Resources (해외 지식정보 협력망을 위한 장서 분석에 관한 연구)

  • Kim, You-Seung;Lee, Jeong-Soo;Kim, Moon-Jeong
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.3
    • /
    • pp.233-257
    • /
    • 2008
  • The integration, openness, participation, and technology are essential elements of digital information resources in order to establish an unified and cooperative network of various digital knowledge-information abroad. This study analyzes policies, technologies and administrative aspects of international cooperative networks such as WDL, IPL, TEL. Based on the analysis, a number of collection standards for international cooperation are drawn. Analyzed standards are divided into four different aspects and applied to produce detailed appraisal standards for digital knowledge-information. In conclusion, in order to map out strategies and policies for developing an international cooperative network, the study proposes a number of principles and models for making an appraisal of collections.

Brain Activation Associated with Set Size During Random Number Generation (무선열 생성과제에서 반응후보 수에 따른 뇌활성화 양상)

  • Lee, Byeong-Taek;Kim, Cheong-Tag
    • Korean Journal of Cognitive Science
    • /
    • v.19 no.1
    • /
    • pp.57-74
    • /
    • 2008
  • This study aimed to investigate the preferential brain activations involed in the set size during random number generation (RNG). The BNG condition gave more increased activations in the anterior cingulate cortex (ACC), inferior frontal gyrus (IFG), inferior parietal lobule (IPL), and superior temporal gyrus (STG) than the simple counting condition, which was a control rendition. When the activations were compared by the small set size condition versus the large set size condition, broad areas covering tempore-occipital network, ACC, and postcentral gyrus were more highly activated in the small set size condition than in the large set size condition, while responses of areas including medial frontal gyrus, superior parietal lobule, and lingual gyrus were more increased in the large set size condition than in the small set size condition. The capacity hypothesis of working memory fails to explain the results. On the contrary, strategy selection hypothesis seems to explain the current observations properly.

  • PDF