• Title/Summary/Keyword: IEEE-383

Search Result 8, Processing Time 0.018 seconds

Performance Analysis of Collision Avoidance Protocols in IEEE 802.15.4 (IEEE 802.15.4의 충돌 회피 프로토콜 성능 분석을 위한 수학적 접근)

  • Park, Woo-Jin;Park, Hong-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.383-385
    • /
    • 2007
  • IEEE 802.15.4 is a standard designed for low rate wireless personal area networks(LR-WPANs). This paper presents the analytical model for to derive the saturation throughput of collision avoidance protocol of IEEE 802.15.4 in ad hoc network. we assume that nodes placed according to a two-dimensional Poisson distribution.

  • PDF

A Study on Validation Methodology of Fire Retardant Performance for Cables in Nuclear Power Plants (원자력발전소 케이블 난연성능 검증 방법론 개선을 위한 연구)

  • Lee, Sang Kyu;Moon, Young Seob;Yoo, Seong Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.140-144
    • /
    • 2017
  • Fire protection for nuclear power plants should be designed according to the concept of "Defense in Depth" to achieve the reactor safety shutdown. This concept focuses on fire prevention, fire suppression and safe shutdown. Fire prevention is the first line of "Defense in Depth" and the licensee should establish administrative measures to minimize the potential for fire to occur. Administrative measures should include procedures to control handling and use of combustibles. Electrical cables is the major contributor of fire loads in nuclear power plants, therefore electrical cables should be fire retardant. Electrical cables installed in nuclear power plants should pass the flame test in IEEE-383 standard in accordance with NUREG-0800, "Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants". To assure the fire retardant of electrical cables during design life, both aged and unaged cable specimens should be tested in accordance with IEEE-383. It can be generally thought that the flammability of electrical cables has been increased by wearing as time passed, however the results from fire retardant tests performed in U.S.A and Korea indicate the inconsistent tendency of aging and consequential decrease in flammability. In this study, it is expected that the effective methodology for validation of fire retardant performance would be identified through the review of the results from fire retardant tests.

Study on the Security-Constrained Optimal Power Flow (상정사고를 고려한 최적조류계산 연구)

  • Choi, Kil;Won, Jong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.381-383
    • /
    • 2002
  • This paper proposes a MATLAB program for solving security-constrained optimal power flow using linear programming. Security-constrained optimal power flow can find an optimal generation satisfying bus voltage limits, line flow limits, reactive generation limits, even if contingency occurs. Sensitivity matrixes are obtained based on power flow solutions with and without single line contingency. This program is tested for an IEEE 14bus system with 5 generators Results shows good ability of finding optimal solution in case of a single line contingency.

  • PDF

Application of FDS for the Hazard Analysis of Lubricating Oil Fires in the Air Compressor Room of Domestic Nuclear Power Plant (국내 원자력발전소의 공기 압축기실에서 윤활유 화재의 위험성 분석을 위한 FDS의 활용)

  • Han, Ho-Sik;Hwang, Cheol-Hong;Baik, Kyung Lok;Lee, Sangkyu
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.1-9
    • /
    • 2016
  • The standard procedure of fire modeling was reviewed to minimize the user dependence, based on the NUREG-1934 and 1824 reports. The hazard analysis of lubricating oil fires in the air compressor room of domestic nuclear power plant (NPP) was also performed using a representative fire model, FDS (Fire Dynamics Simulator). The area ($A_f$) and location of fire source were considered as major parameters for the realistic fire scenarios. As a result, the maximum probability to exceed the thermal damage criteria of IEEE-383 unqualified electrical cables was predicted as approximately 70% with $A_f=1m^2$. It was also found that for qualified electrical cables, the maximum probabilities of exceeding the criteria were 2% and 90% with $A_f=2$ and $4m^2$, respectively. It was concluded that all electrical cables should be replaced with IEEE-383 qualified cables and the dike to restrict as $A_f{\leq}2m^2$ should be installed at the same time, in order to assure the thermal stability of electrical cables for lubricating oil fires in the air compressor room of domestic NPP.

Temporal Fairness Provisioning in Wirless LANs Considering Transport Layer Protocols (전송계층을 고려한 무선랜의 시간 공정성 보장)

  • Kang, Ji-Myung;Cho, Seong-Ho;Choi, Sun-Woong;Kim, Chong-Kwon
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.5
    • /
    • pp.374-383
    • /
    • 2008
  • IEEE 802.11 WLANs support various data rates in order to adapt to wireless channel condition. It is known that when some WLAN stations use a lower data rate than the others, total throughput is considerably degraded. The concept of temporal fairness which provides equal time to all stations has been introduced to alleviate this performance anomaly problem. However, most previous mechanisms assume that stations have infinite backlogs in the MAC layer and do not consider transport layer. In this paper, we first examine and analyze the performance of previous methods considering transport layer protocols. We then propose two new temporal fairness guarantee methods: AP priority and dynamic CWmin adjustment. We carried out extensive performance study via ns-2 computer simulations. The results show that the proposed methods provide temporal fairness and improve the throughput of WLANs in various environments.

Self-Organization of Fuzzy Rules for Netwrok Performance Manager (퍼지 네트워크 성능관리기의 퍼지 룰 자기 구성)

  • Kim, In-Jun;Lee, Gyoung-Chang;Lee, Sang-Ho;Lee, Suk
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.379-383
    • /
    • 1997
  • This paper focuses on self-organization of fuzzy rules for performance management of computer communication networks serving manufacturingsystems. The performance managment aims to improve the network performance in handling various types of messages by on-line adjustment of protocol parameters. The principle of fuzzy logic has been used in repressenting the knowledge of human expert on the performance management and in deriving manafement decisions. In this paper, we present an of this self-organization is domonstrated by discrete simulation of an IEEE 802.4 network.

  • PDF

Design of Fuse Mounted Elbow Connector (퓨즈가 내장된 엘보접속재의 설계)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

Experimental Study of Fire Characteristics of a Tray Flame Retardant Cable (트레이용 난연 전력 케이블의 화재특성에 관한 실험적 연구)

  • Kim, Sung Chan;Kim, Jung Yong;Bang, Kyoung Sik
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.39-43
    • /
    • 2013
  • The present study has been conducted to investigate the fire combustion properties and fire behavior of an IEEE-383 qualified flame retardant cable. The reference reaction rate and reference temperature which are commonly used in pyrolysis model of fire propagation process was obtained by the thermo-gravimetric analysis of the cable component materials. The mass fraction of FR-PVC sheath abruptly decreased near temperature range of $250{\sim}260^{\circ}C$ and its maximum reaction rate was about $2.58{\times}10^{-3}$[1/s]. For the XLPE insulation of the cable, the temperature causing maximum mass fraction change was ranged about $380{\sim}390^{\circ}C$ and it has reached to the maximum reaction rate of $5.10{\times}10^{-3}$[1/s]. The flame retardant cable was burned by a pilot flame meker buner and the burning behavior of the cable was observed during the fire test. Heat release rate of the flame retardant cable was measured by a laboratory scale oxygen consumption calorimeter and the mass loss rate of the cable was calculated by the measured cable mass during the burning test. The representative value of the effective heat of combustion was evaluated by the total released energy integrated by the measured heat release rate and burned mass. This study can contribute to study the electric cable fire and provide the pyrolysis properties for the computational modeling.