• Title/Summary/Keyword: IEC Standards

Search Result 516, Processing Time 0.039 seconds

Analysis and optimization of Wiel-Dobke synthetic testing circuit parameters (Weil-Dobke 합성단락 시험회로의 Parameter 분석과 최적화)

  • Kim, Maeng-Hyun;Rhyou, Hyeong-Kee;Park, Jong-Wha;Koh, Hee-Seog
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.623-627
    • /
    • 1995
  • This paper describes analysis and optimization of Weil-Dobke synthetic testing circuit parameters, which is efficient and economical test method in high capacity AC circuit breaker. In this paper, analysis of synthetic short-circuit test circuit parameter proposed nondimensional factor that is reciprocal comparison value of circuit parameter and is not related to rated of circuit breaker, in particular, this study induce minimization of required energy of critical TRV generation specified in IEC 56 standards and present optimal design of synthetic short circuit testing facilities.

  • PDF

Implementation of the contact and contactless IC Card OS for Java Card (자바 카드에서 접촉 및 비접촉 겸용 IC카드 OS의 설계 및 구현)

  • 주홍일;손수호;전용성;전성익
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.375-378
    • /
    • 2002
  • This paper describes tile design and implementation of contact and contactless If card OS(Operating System) for Java Card, namely JCOS(Java Card 05). The JCOS complies with ISO/IEC 7816 and IS0/1EC 14443 standards. The JCOS conforms to Java Card 2.1.2 specifications. The JCOS is running on 32-bit ARMTTDMI with public key crypto-coprocssor. This paper describes only the dual-interface protocol of the JCOS which supports contact and contactless applications in a single chip. The JCOS has been completed with our sample banking service and access control service in ETRI up to now.

  • PDF

소프트웨어 시험평가 모델 설계에 관한 연구(공공분야 CALS/EC 중심으로)

  • 임만택;이상호;김성용;변재정
    • Proceedings of the CALSEC Conference
    • /
    • 1999.07a
    • /
    • pp.193-205
    • /
    • 1999
  • Nowadays, public domain software CALS/EC projects give their attention to the importance of test and evaluation (T&E). This article proposed a survey on T&E procedures of the international standards ISO 9000-3, ISO/IEC 9126 and ISO 14598, and of the U.S. Army pamphlet as well as that of MIL-STD-498. And features of testing tools such as their characteristics were reviewed for a reference in selecting appropriate one. Large-scale software projects often encounter with problems during T&E, when they become close to the end of development cycle. The problems generally act as a bottleneck of a project, leading to slippage of the entire schedule. This article tried a close look at the problems and solution alternatives of the T&E policy, management, and technical issues, and proposed a T&E model to support a variety of software development environment.

  • PDF

Advancement Directions for Korean Railway Standard(KRS) Corresponding to the Trend of International Standard in Electric Railway (전기철도분야 국제 표준화 흐름에 대응한 한국철도표준규격의 발전 방향)

  • Lee, Chang-Young;Kwon, Sung-Tae;Kim, Jeong-Guk;Baek, Seung-Koo;Chang, Seok-Gahk
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1156-1164
    • /
    • 2006
  • According to Korean railway safety law and its ordinances, the Korean railway standard(KRS)s to recommend railway operators and manufacturers the regulations for safety and inter-operability of railway system were enacted in the early 2006. In order to reflect rapidly advancing railway technologies and correspond to the international railway standard led by Europe and Japan, KRSs should be confirmed and revised continuously. This paper deals with recent trends in enacting international standards by IEC and the Europe and Japan's activities for this, and presents advancement directions for KRS.

  • PDF

System Level ESD Analysis - A Comprehensive Review II on ESD Coupling Analysis Techniques

  • Yousaf, Jawad;Lee, Hosang;Nah, Wansoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2033-2044
    • /
    • 2018
  • This study presents states-of-the art overview of the system level electrostatic discharge (ESD) analysis and testing. After brief description of ESD compliance standards and ESD coupling mechanisms, the study provides an in-depth review and comparison of the various techniques for the system level ESD coupling analysis using time and frequency domain techniques, full wave electromagnetic modeling and hybrid modeling. The methods used for improving system level ESD testing using troubleshooting and determining the root causes of soft failures, the optimization of ESD testing and the countermeasures to mitigate ESD problems are also discussed.

A Study on the lighting Installation Regulations in Waterpark, Public Bath and Similar Places for the Prevention of Electrical Shock (감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설규정 연구)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Gi-Hyun;Hwang, Kwang-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.339-344
    • /
    • 2005
  • A person's body resistance in the waterpark, public bath and similar places is lower than any other places due to effect of water. So low voltage may create a shock hazard for the human body in case of leakage or fault currents from lighting unit etc. We researched the related regulations these are internal standards, NEC, IEC and investigated the actual conditions for the prevention of electrical shock due to lighting units in the waterpark, public bath and similar places. So we could present actual facilities's problems and solutions

  • PDF

Comparison and Analysis of Domestic and Foreign Standard for electrical equipment installation of amusement park and ride (유원시설 전기설비 설치에 대한 국내외 규정 비교 분석)

  • Kim, Gi-Hyun;Kim, Chong-Min;Kim, Han-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.378-382
    • /
    • 2004
  • This paper gives information which is applied to install the electrical equipment of amusement park and ride. For analyzing the standard of electrical equipment installation, we research the related regulation of National Electrical Code(2002), IEC 60364-series and Technical standards for Electrical facilities of internal standard. Among electrical equipments of amusement park and ride, especially we study the transformer vaults, overcurrent protection and ground protection of electrical equipment. So we the furnished the installation information of transformer vaults, overcurrent and ground protection at amusement park and ride.

  • PDF

A Leakage Current Analysis of EHV Porcelain Insulators by Artificial Contamination Method (초고압 송전용 자기애자의 인공오손법을 통한 누설전류 분석)

  • Choi, In-Hyuk;Choi, Jang-Hyun;Jung, Yoon-Hwan;Lee, Dong-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.65-68
    • /
    • 2004
  • This paper researched leakage current characteristics of artificially contaminated EHV insulators through construction of long-term testing facility. Insulators were contaminated and classified into the ESDD contaminated levels under IEC standards method. As the test results of contaminated insulators was carried out several experiments, leakage current greatly increased during initial rainfall. After contaminated insulators were naturally washed by rain, leakage current was not increased.

  • PDF

Analysis of Maximum Generating Power Drop of PV Module Under the Continuous Artificial Light Irradiation Test Condition (연속 광조사 조건에서의 태양전지모듈의 연간 최대출력 저하율 변화 예측 분석)

  • Kim, Kyungsoo;Yun, Jaeho
    • Current Photovoltaic Research
    • /
    • v.6 no.3
    • /
    • pp.69-73
    • /
    • 2018
  • PV system is consisted with PV module, inverter and BOS(balance of system). To have robustic operation more than 20 years, the expected and guaranteed durability and reliability of products should be met. Almost components of PV system are qualified through IEC standards at test laboratory. But the qualification certificate of product does not ensure long-term nondefective operation. PV module's expected life time is nowadays more than 20 years and annual maximum power degradation ratio would be less than -1%. But the power degradation ratio is basically based on real data more than several years' record. Developing test method for ensuring annual maximum power degradation ratio is very need because there are many new products every month with new materials. In this paper, we have suggested new test method under continuous artificial light irradiation test condition for analyze expected maximum power drop ratio.

A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads (고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong;Lee, Il-Moo;Kim, Joo-Rak
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF