• Title/Summary/Keyword: ID-LC/MS

Search Result 20, Processing Time 0.02 seconds

Accurate Quantification of Saccharin Using Isotope Dilution Liquid Chromatography Mass Spectrometry (ID-LC/MS)

  • Lee, Yun-Jung;Kim, Byung-Joo;Kim, Jeong-Kwon;Ahn, Seong-Hee
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.37-40
    • /
    • 2011
  • Saccharin is a commonly used artificial sweetener in foodstuffs. However, for its carcinogenic dispute, it has been regulated by government bodies. In this study, isotope dilution mass spectrometry (ID-MS) was introduced for the accurate quantification of saccharin. To employ ID-LC/MS, we obtained its isotope analogue, $^{13}C_1$-sodium saccharin, by customized synthesis. Samples were spiked with $^{13}C_1$-sodium saccharin and analyzed with LC/MS in negative mode. Chromatographic conditions were optimized for the adequate chromatographic retention and separation of saccharin with a $C_{18}$ column. MS was operated with electrospray ionization by the selected ion monitoring (SIM) mode of $[M-H]^-$ for saccharin (m/z 182) and $[M-Na]^-$ for its isotope analogue (m/z 183). To validate the ID-LC/MS method for accurate measurement, we prepared a batch of a candidate material by sortifying quasi-tea-drinks with saccharin and analyzed samples gravimetrically fortified in various levels of concentration. The repeatability and reproducibility of this method was tested by analyzing the reference material. Result show that ID-LC/MS is a reliable method for the quantitative analysis of saccharin.

Development of an Isotope Dilution Mass Spectrometry (IDMS)-Based Method for the Analysis of Ibuprofen

  • Lee, Joonhee;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.49-52
    • /
    • 2017
  • Ibuprofen is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometry method based on LC/MS was developed as a candidate reference method for the accurate determination of ibuprofen in pharmaceutical tablets. Isotope labelled ibuprofen, $ibuprofen-d_3$, was added as an internal standard into sample extracts. Ibuprofen and $ibuprofen-d_3$, was analysed by LC/MS in a selected ion monitoring (SIM) mode to detect ions at m/z 205 and 208, respectively. The repeatability and reproducibility of the developed ID-LC/MS method were tested for the validation and assessment of metrological quality of the method.

Development of an Isotope-Dilution Liquid Chromatography/Mass Spectrometric Method for the Accurate Determination of Acetaminophen in Tablets

  • Shin, Hyun-Ju;Kim, Byung-Joo;Lee, Joon-Hee;Hwang, Eui-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3663-3667
    • /
    • 2010
  • Acetaminophen (N-acetyl-p-aminophenol) is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometric method based on LC/MS was developed as a candidate reference method for the accurate determination of acetaminophen in pharmaceutical product. After spiking an isotope labeled acetaminophen (acetyl-$^{13}C_2$, $^{15}N$-acetaminophen) as an internal standard, tablet extracts were analyzed by LC/MS in a selected reaction monitoring (SRM) mode to detect ions at m/z $152{\rightarrow}110$ and m/z $155{\rightarrow}111$ for acetaminophen and acetyl-$^{13}C_2$, $^{15}N$-acetaminophen, respectively. The repeatability and reproducibility of the developed ID/LC-MS method were tested for the validation and assessment of metrological quality of the method.

Optimization of Enzyme Digestion Conditions for Quantification of Glycated Hemoglobin Using Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry

  • Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.52-56
    • /
    • 2014
  • Glycated hemoglobin (HbA1c) is used as an index of mean glycemia over prolonged periods. This study describes an optimization of enzyme digestion conditions for quantification of non-glycated hemoglobin (HbA0) and HbA1c as diagnostic markers of diabetes mellitus. Both HbA0 and HbA1c were quantitatively determined followed by enzyme digestion using isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) with synthesized N-terminal hexapeptides as standards and synthesized isotope labeled hexapeptides as internal standards. Prior to quantification, each peptide was additionally quantified by amino acid composition analysis using ID-LC-MS/MS via acid hydrolysis. Each parameter was considered strictly as a means to improve digestion efficiency and repeatability. Digestion of hemoglobin was optimized when using 100 mM ammonium acetate (pH 4.2) and a Glu-C-to-HbA1c ratio of 1:50 at $37^{\circ}C$ for 20 h. Quantification was satisfactorily reproducible with a 2.6% relative standard deviation. These conditions were recommended for a primary reference method of HbA1c quantification and for the certification of HbA1c reference material.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Folic Acid in Infant Milk Formula

  • Jung, Min-Young;Kim, Byung-Joo;Boo, Doo-Wan;So, Hun-Young
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.745-750
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of folic acid in infant milk formula. Sample was spiked with 13C5-folic acid and then extracted with phosphate buffer (pH 6) solution. The extract was further cleaned up by deproteinization followed by a C18 solid-phase extraction cartridge. The extract was analyzed by using LC/ ESI/MS/MS with selectively monitoring the collisionally induced dissociation channels of m/z 442 → m/z 295 and m/z 447 → m/z 295, which are the neutral glutamyl loss from the [M+H]+ ions of folic acid and 13C5-folic acid, respectively. LC/MS/MS chromatograms showed substantially reduced background from chemical noises compared to LC/MS chromatograms. Repeatability and reproducibility studies showed that the LC/MS/ MS method is a reliable and reproducible method which can provide less than 1.5 relative percentage of method precision.

Analysis of sorbic acid in tea-drink using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) (동위원소희석 액체 크로마토그래피-질량분석법을 이용한 차음료 중의 소르빈산의 분석)

  • Ahn, Seong-Hee;Lee, In-Sun;Kim, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2012
  • Isotope dilution mass spectrometry (ID-MS) based on liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed for the accurate determination of sorbic acid in tea-drink. An isotope analogue of sorbic acid, $^{13}C_2$-sorbic acid, was obtained by custom synthesis. MS was operated in the negative mode with selected reaction monitoring (SRM) mode of $[M-H]^-$ ${\rightarrow}$ $[M-CO_2H]^-$ channel at m/z 111 ${\rightarrow}$ 67 for sorbic acid and at m/z 113 ${\rightarrow}$ 68 for its isotope analogue. Chromatographic separation was accomplished with a C18 column and an isocratic mobile phase of 55% of 50 mM ammonium acetate (pH 4.5) and 45% of methanol. Homogeneous reference materials were prepared for validation of this method, including repeatability and reproducibility tests, by fortifying tea-drink with sorbic acid in our laboratory. Repeatability and reproducibility studies showed that the ID-LC/MS method is a reliable and reproducible method which provides less than 3.8% of relative standard deviation (RSD) for the analysis of sorbic acid.

Development of Isotope Dilution-Liquid Chromatography/Tandem Mass Spectrometry as a Candidate Reference Method for the Determination of Acrylamide in Potato Chips

  • Park, Sun-Young;Kim, Byung-Joo;So, Hun-Young;Kim, Yeong-Joon;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.5
    • /
    • pp.737-744
    • /
    • 2007
  • An isotope dilution-liquid chromatography/tandem mass spectrometric method was developed as a candidate reference method for the accurate determination of acrylamide in potato chips, starch-rich foodstuff cooked at high temperature. Sample was spiked with 13C3-acrylamide and then extracted with water. The extract was further cleaned up with an Oasis HLB solid-phase extraction (SPE) cartridge and an Oasis mixed-phase cation exchange (MCX) SPE cartridge. The extract was analyzed by using LC/ESI/Tandem MS in positive ion mode. LC with a medium reversed-phase (C4) column was optimized to obtain adequate chromatographic retention and separation of acrylamide. MS was operated to selectively monitor [M+H]+ ions of the analyte and its isotope analogue at m/z 72 and m/z 75, respectively. Sample was also analyzed by the LC/MS with selectively monitoring the collisionally induced dissociation channels of m/z 72 → m/z 55 and m/z 75 → 58. Compared to the LC/MS chromatograms, the LC/MS/MS chromatograms showed substantially reduced background chemical noises coming from solvent clusters formed during ESI spray processes and interferences from sample matrix. Repeatability and reproducibility studies showed that the LC/MS/MS method is a reliable and reproducible method which can provide a typical method precision of 1.0% while the LC/MS results are influenced by chemical interferences.

Accurate Determination of Malachite Green and Leucomalachite Green in Fish using Isotope Dilution Liquid Chromatography/Mass Spectrometry (ID-LC/MS)

  • Ahn, Seong-Hee;Kim, Byung-Joo;Lee, Yun-Jung;Kim, Jeong-Kwon
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3228-3232
    • /
    • 2010
  • Malachite green (MG) has been used world-widely in aquaculture as a parasiticide or fungicide. Although MG performed successfully, it has not been permitted for use in aquaculture from European Union, USA, and Canada because of its carcinogenicity and mutagenicity. We developed a sensitive and specific method to determine MG and its principal metabolite, leucomalachite green (LMG), respectively by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS). To enhance the extraction recovery of MG and LMG from fish tissue, an additional step, saponification, was introduced in sample preparation process to remove fat in sample extract, which hampered the performance of SPE columns. The residue of MG and LMG in fish was analyzed using liquid chromatography mass spectrometry in the selected ion monitoring (SIM) mode by monitoring at m/z 329 and 334 for MG and $d_5$-MG and at m/z 331 and 337 for LMG and $^{13}C_6$-LMG, respectively. This method was validated by comparing with the value of the reference material provided by Laboratory Government Chemistry (LGC). The results agreed within the measurement uncertainty and the accuracy was much improved than the provided reference value by LGC.

Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS) (동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구)

  • Song, Hye-Min;Kim, Byung-Joo;Jeong, Hyuk;Ahn, Seong-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.524-530
    • /
    • 2010
  • Chloramphenicol is one of the most effective antibiotics for treatment of food-producing animals for typhoid fever. However, it has been reported that it caused severe side effects such as aplastic anemia in human, therefore the use of chloramphenicol for food-producing animal is prohibited by European Union and other countries. In this study, the analytical method using isotope dilution liquid chromatography-mass spectrometry (ID-LC/MS) was established for accurate determination of chloramphenicol in meat. Chloramphenicol was extracted with ethylacetate from porcine and solid phase extraction cartridge was used for enhancing the recovery. The residue of chloramphenicol in porcine was analyzed using the liquid chromatography mass spectrometer (LC/MS) interfaced with electrospray ionization source. Analysis was performed in negative mode with selected reaction mornitoring mode at m/z 321${\rightarrow}$257 of $[M-H]^-$ ${\rightarrow}$ $[M-H-(HCOCl)]^-$ and m/z 326 ${\rightarrow}$ 262 channels for its isotope. The established method was tested using fortified samples at the level of 0.2 1, 10, $25\;{\mu}g$/kg and analytical results agreed with the gravimetrically fortified values within their uncertainties. This method was validated by analyzing a certified reference material, BCR 445, from IRMM (Institute for Reference Materials and Measurement). Our measurement values agreed with the certified value within their uncertainties. The uncertainty of our measured value was much lower than that the certified value from IRMM.