• Title/Summary/Keyword: IAQ (indoor Air Quality)

Search Result 188, Processing Time 0.033 seconds

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

A study on Forced Ventilation Rate for Bedroom Indoor Air Quality Improvement (침실 공기질 개선을 위한 강제 환기횟수에 관한 연구)

  • Kim, Dong-Gyu;Lee, Sung;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.85-90
    • /
    • 2009
  • The indoor air quality is one of the most important issues of designing ventilation in high rise apartment buildings. This study suggested proper ventilation rate in the apartment bedroom where mechanical ventilation system has installed. Six university students(four male and two female) were participating in the experiment. Experiments were performed in environmental chamber. Experimental conditions were combinations from three ventilation rate 0, 0.4 and 0.7. Measurement items during 8 hours of experimental time were temperature, humidity, carbon dioxide concentrations and questionnaire surveyed aftrer sleeping. The concentration of Carbon Dioxide depending on ventilation rate in the chamber was analyzed for proper ventilation rate. The results of this paper can be summarized as follows. (1) When two persons experiment, 0.7 ventilation rate was in excess of 1000ppm. (2) When one person experiment, 0.7 and 0.4 ventilation rates were satisfied the criteria of IAQ. (3) It compared 0.4 with 0.7 in the ventilation rate, 0.4 ventilation rate could reduced about 80% of the power by fan similarity law.

A Study on the Application of VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) for Indoor Air Environment (VAV/BPFS(Variable-Air-Volume/Bypass Filtration System) 의 실내환경 적응에 관한 연구)

  • 최성우
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1235-1243
    • /
    • 2003
  • Under controlled conditions in an environmental chamber, 24 experiments were performed to compare the ability of a Variable-Air-Volume/Bypass Filtration System(VAV/BPFS) to remove indoor pollutants and to conserve energy with the ability of conventional Variable Air Volume(VAV) system. The specific conclusions of this paper were; first, the VAV/BPFS was more efficient than the VAV system in removing particulate matter, TVOC, and target VOCs. The total effective removal rate of PM for the VAV/BPFS was two times as high as that of the VAV system. The total effective removal rate of TVOC for the VAV/BPFS was 20 percent higher than that of the VAV system. Also each target VOC concentration was reduced by using the VAV/BPFS. Second, clean air delivery rate was increased by using VAV/BPFS due to additional filtration rate. Otherwise, the VAV/BPFS decreased outdoor supply air rate above 25 percent relative to the rate of VAV system. Third, total energy consumption by the VAV/BPFS was lower than that of the VAV system during the period with indoor thermal load, occupied time. The energy saving of the VAV/BPFS ranged from 11 to 16 percent. The VAV/BPFS improves indoor air quality more efficiently than the VAV system, and it reduced energy consumption. Retrofitting the VAV system with the VAV/BPFS was easy The use of VAV/BPFS is, therefore, recommended far buildings with VAV system as well as for buildings at designing stage.

Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles (천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가)

  • Lee, Jin-Hyung;Kim, You-Jae;Choi, Weon-Seok;Park, Sung-Kwan;Youn, Baek;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.

  • PDF

Variation of Formaldehyde Concentration in Preschool Facilities by Location and Indoor/Outdoor (유아교육시설의 위치 및 실내${\cdot}$실외에 따른 포름알데히드 농도 변화)

  • Yoon , Chung-Sik;Jeong , Jee-Yeon;Yi , Gwang-Yong;Park , Dong-Uk;Park , Doo-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.3
    • /
    • pp.259-263
    • /
    • 2004
  • This study was performed to investigate airborne formaldehyde concentration in preschool facilities. Arithmetic mean of indoor formaldehyde concentration in urban area was 34.9 ppb(Geometric mean 24.4 ppb) whereas outdoor concentration was 21.5 ppb(GM 11.9 ppb). In rural area, formaldehyde concentrations were 36.4 ppb(GM 28.7 ppb), 4.1 ppb(GM 4.1 ppb), respectively. There is no statistical significance between the formaldehyde concentrations of urban classrooms and those of rural area. We verified that the distribution of airborne formaldehyde concentration was log-normal characteristic using Shapiro and Wilk test. The 6.7% of urban indoor samples was exceeded the domestic standard limit of indoor air quality. From our study and other study, we concluded that the major emission sources of formaldehyde in preschool facilities was in indoor rather than outdoor.

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF

Analysis of Comfortable Environment in the Classroom with Humidification and Ventilation in Winter (겨울철 가습 및 환기에 따른 교실내 쾌적환경 분석)

  • Cheong, Seong-Ir;Sheng, Nai-Li;Kim, Doo-Hyun;Lee, Jae-Keun;Hwang, Yu-Jin;Park, Jong-Hoon;Seo, Seok-Jang
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.7
    • /
    • pp.402-408
    • /
    • 2009
  • In this paper, the effects of ventilation and humidification on thermal comfort and indoor air quality(IAQ) were evaluated in a classroom when a heat pump system was operated in winter. Thermal comfort parameters, such as temperature, relative humidity, globe temperature and air velocity, were measured at 9 points in the classroom. The concentration of $CO_2$ and total suspended particles(TSP) in the classroom were measured in order to analyze IAQ. Temperature distribution in the classroom was decreased by $2{\sim}5^{\circ}C$ when the ventilation system and the humidifier were operated. When the relative humidity was adjusted to 60% by operating the humidifier and the ventilation system, the predicted mean vote(PMV) in the classroom was within the comfortable range of $-0.5{\sim}0.5$. When the ventilation system was operated, the average concentration of $CO_2$ and TSP were decreased by 645 ppm and 0.17 $mg/m^3$, respectively. This paper suggests the humidification and ventilation conditions to maintain the comfortable environment in the school classroom in winter experimentally.

A Study on Assessment of IAQ(Indoor Air Quality) for Underground Environments in Seoul (서울시 일부 지하공간에서의 실내공기질 평가에 관한 연구)

  • 정진원;김윤신;윤동원;권성안
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.04a
    • /
    • pp.304-306
    • /
    • 2000
  • 오늘날 경제적 생활 환경의 개선으로 인하여 현대인의 생활에 많은 변화를 가져오고 있다 제한된 공간에서 인간 활동은 지하생활공간이라는 새로운 활동영역을 창출하였고, 이에 따라 실내에서의 거주 시간은 더욱 증가하고 있다. 지하생활공간이라는 용어가 일반인들에게는 다소 생소하게 받아들여질 수 있지만 여기서 말하는 지하생활공간이라 함은 불특정 다수인이 이용하는 지하철, 지하상가, 지하주차장, 지하 보·차도, 지하터널 등을 말하며 개인의 생활 양식에 따라 단시간 이용하거나 또는 생활터전으로 장시간 거주할 수 있는 공간이라고 할 수 있다. (중략)

  • PDF

An experimental study on the emission of volatile organic compounds(VOCs) from carpet (카페트에서 방출되는 VOCs에 관한 실험적 연구)

  • 신동민;김창녕;천만영
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.177-178
    • /
    • 2002
  • 최근 국내의 생활 문화가 점차 서구화되어 가면서 카페트를 사용하는 장소가 증가하고 있으며, 실내 소음 방지, 보온, 분위기 조성 등을 위한 목적으로 카페트의 사용범위는 점차 넓어지고 있다. 하지만 이러한 카페트는 실내 VOCs 방출원 중의 하나로 보고되고 있으며, 여기서 방출된 VOCs는 실내 공기질(Indoor Air Quality: 이하 IAQ라 칭함)저하를 유발하는 요소 중의 하나이다. (중략)

  • PDF

A study of the paint characteristic evaluation for building complete materials (건축용 마감재 페인트의 성능평가에 관한 연구)

  • Park, Min-Su;Kim, Sun-Tae;Son, Chan-Woong;Kim, Han-Tae;Lee, Baek-Hyun
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.177-178
    • /
    • 2002
  • 최근 삶의 질이 향상은 건강에 대한 환경적 관심으로 연계되고 있다. 특히 현대인의 생활양식과 근무양식이 1일 실내 생활시간이 전체의 80%이상으로 변화함에 따라 실내공기질(Indoor Air Quality : 이하 IAQ)이 인간에게 직접적인 미치는 영향에 대해 높은 관심을 나타내고 있다. 실내공기는 일정수준의 외기 도입이 없는 경우, 한정된 공간을 오염된 공기가 계속 순환하면서 오염물질이 누적될 수 있다. (중략)

  • PDF