• Title/Summary/Keyword: Hysteresis control

Search Result 485, Processing Time 0.024 seconds

Two Vector Based Direct Power Control of AC/DC Grid Connected Converters Using a Constant Switching Frequency

  • Mehdi, Adel;Reama, Abdellatif;Benalla, Hocine
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1363-1371
    • /
    • 2017
  • In this paper, an improved Direct Power Control (DPC) algorithm is presented for grid connected three phase PWM rectifiers. The new DPC approach is based on two main tasks. First the optimization of the look-up table, which is well-known in conventional DPC, is outlined for selecting the optimum converter output voltage vectors. Secondly a very simple and effective method is used to directly calculate their duty cycles from the power errors. Therefore, the measured active and reactive powers are made to track their references using hysteresis controllers. Then two vectors are selected and applied during one control cycle to minimize both the active and reactive power ripples. The main advantages of this method are that there is no need of linear current controllers, coordinates transformations or modulators. In addition, the control strategy is able to operate at constant switching frequencies to ease the design of the power converter and the AC harmonic filter. The control exhibits a good steady state performance and improves the dynamic response without any overshoot in the line current. Theoretical principles of the proposed method are discussed. Both simulation and experimental results are presented to verify the performance and effectiveness of this control scheme.

A Hysteresis Controllable Monolithic Comparator Circuit for the Radio Frequency Identification (RFID 히스테리시스 제어용 CMOS 비교기 IC 회로)

  • Kim, Young-Gi
    • Journal of IKEEE
    • /
    • v.15 no.3
    • /
    • pp.205-210
    • /
    • 2011
  • A novel hysteresis tunable monolithic comparator circuit based on a 0.35 ${\mu}m$ CMOS process is suggested in this paper. To tune the threshold voltage of the hysteresis in the comparator circuit, two external digital bits are used with supply voltage of 3.3V. The threshold voltage of the suggested comparator circuit is controlled by 234mV by change of 4 digital control bits in the simulation, which is a close agreement to the analytic calculation.

Digital implementation of PID autotuner (PID 자동동조기의 디지틀 구현)

  • 이상정;김인중;홍석민
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.311-316
    • /
    • 1991
  • This paper deals with designing the PID autotuner. The system parameters are identified using the relay control, where the unidirectional relay with hysteresis is adopted. The digital PID tuning rule on Nyquist plot is derived, and the statistical wordlength is adopted for the coefficient wordlength. The experimental results of temperature control exhibit the satisfactory performance and the validity of the derived statistical wordlength.

  • PDF

Settlement behaviours and control measures of twin-tube curved buildings-crossing shield tunnel

  • Jianwei, Jia;Ruiqi, Gao;Defeng, Wang;Jianjun, Li;Ziwen, Song;Jinghui, Tan
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.699-706
    • /
    • 2022
  • Settlement control techniques are critical for the safety of shield tunnel constructions, especially for facing complex situations. In this study, the shield tunnel structure from Huaita east road station to Heping Road station in Xuzhou metro No.3 line (China) is taken as engineering background, which has various complex problems of the upper-soft and lower-hard composite stratum conditions, twin curve shield tunnels, and underpass the foundation of the piled raft. The deformation characteristics of shield tunnelling passing through buildings are explored. Subsequently, comprehensive research methods of numerical simulation and field measurement are adopted to analyzing the effectiveness of settlement control by using the top grouting technique. The results show that the settlement of the buildings has obvious spatial characteristics, and the hysteresis effect can be obviously observed in soil deformation caused by shield construction. Meanwhile, the two shield constructions can cause repeated disturbances, reducing the soil deformation's hysteresis effect. Moreover, the shield tunnel's differential settlement is too large when a single line passes through, and the shield construction of the outer curve can cause more significant disturbance in the tunnel than the inside curve. Notably, the proposed process control parameters and secondary topgrouting method can effectively control the deformation of the shield tunnel, especially for the long-term deformation.

A Hysteresis & PI Current Controller Response Characteristic of SRM (스위치드 릴럭턴스 전동기의 히스테리시스 및 PI 전류제어기 응답특성)

  • Kim, Dong-Hee;Baik, Won-Sik;Kim, Min-Huei
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.25-31
    • /
    • 2007
  • This paper presents a comparison of different current controller response characteristics of SRM. The most common current controllers of the SRM is hysteresis type. The hysteresis controller is easy to implement and fast current control response, but has the inherent disadvantage of switching frequency variations. The other common type of current controller is PI scheme. The design of a classical PI current controller with fixed parameters for SRM is not an easy task due to the extreme nonlinear characteristics. In this paper, some linearization technique is used for design of PI current controller. Experimental results of 1-hp SRM are presented for the basic reference data which can be used to select the proper current control scheme according to the applications.

Modeling, Simulation, and Control of a Polyaniline/Carbon-Nanotube Polymer Actuator (폴리아닐린/탄소나노튜브 폴리머 액츄에이터의 모델링, 시뮬레이션 및 제어)

  • Sohn, Ki-Won;Yi, Byung-Ju;Kim, Sean-Jeong;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.348-354
    • /
    • 2007
  • Polymer actuators, which are also called as smart materials, change their shapes when electrical, chemical, thermal, or magnetic energy is applied to them and are useful in wide variety of applications such as microelectromechanical systems (MEMS), machine components, and artificial muscles. For this study, Polyaniline/carbon-nanotube polymer actuator that is one of electroactive polymer actuators was prepared. Since the nonlinear phenomena of hysteresis and a step response are essential considerations for practical use of polymer actuators, we have investigated the movement of the Polyaniline/carbon-nanotube polymer actuator and have developed an integrated model that can be used for simulating and predicting the hysteresis and a step response during actuation. The Preisach hysteresis model, one of the most popular phenomenological models of hysteresis, were used for describing the hysteretic behavior of Polyaniline/carbon-nanotube polymer actuator while the ARX method, one of system identification techniques, were used for modeling a step response. In this paper, we first expain details in preparation of the Polyaniline/carbon-nanotube polymer then present the mathematical description of our model, the extraction of the parameters, simulation results from the model, and finally a comparison with measured data.

Field Weakening Control of Permanent Magnet Synchronous Motor fed by Hysteresis Current Controlled PWM Inverter (히스테리시스 전류 제어형 PWM 인버터에 의한 영구자석 동기 전동기의 약계자 제어)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Yang, Chun-Suk;Yoon, Myung-Kyun;Yoo, Bo-Min
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.167-170
    • /
    • 1991
  • The back e.m.f. of PMSM is increased as the speed is increased and it saturates the current regulator because it counteracts the available output voltage of the inverter. In the PM motor, however, the required armature terminal voltage can be reduced within the maximum output voltage of the inverter by field weakening control, in which the air gap flux is weakened by the d-axis armature current. In this paper, the field weakening control of the surface PMSM fed by a hysteresis current control led PWM inverter based on the microprocessor is presented. To show the validity of the proposed control method, the simulation and experimental results are provided.

  • PDF

Low Speed Servo System for Brushless Motor (브러시리스 전동기의 저속 서어보 시스템)

  • Lee, Woon-Young;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.162-164
    • /
    • 1994
  • This paper proposes a servo control system of brushless motor at a low and high speed range. The control system is composed of the PI controller for high-speed control and the modified PI controller for low-speed control and the current controller using the hysteresis current control PWM method. The speed control performance is shown by the computer simulation.

  • PDF

A implementation on active silencer using hysteresis control (히스테리시스 제어기법을 이용한 능동 소음기의 구현)

  • 강정유;민휘식;황희융;장도현
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.7
    • /
    • pp.112-122
    • /
    • 1997
  • This paper presents active silencing by hysteresis control method and shows its audible noise reduction effect. A Pentium processor and sound blaster 16 card are used for its implementation. The Sound-Blaster 16 executes the A/D, D/A conversion and is used for operating source of lodspeaker for cancelling. As a result, between the frequency range of 100[Hz] and 200[Hz] there is an audible noise reduction effect from 9[dB] to 15[dB], and between the 300[Hz] and 500[Hz] range there is a reduction from 3[dB] to 5[dB].

  • PDF

Iron Loss Analysis Considering Excitation Conditions Under Alternating Magnetic Fields

  • Hong, Sun-Ki;Koh, Chang-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.33-38
    • /
    • 2010
  • In this paper, the nature of iron loss in electrical steel during alternating field excitation is investigated more precisely. The exact definition of AC iron loss is cleared by accurately measuring the iron loss for conditions of both the sinusoidal magnetic field and sinusoidal magnetic flux density. The results of this approach to iron loss calculations in electrical steel are compared to experimentally-measured losses. In addition, an inverse hysteresis model considering eddy current loss was developed to analyze the iron loss when the input is the voltage source. With this model, the inrush current in the inductor or transformer as well as the iron loss can be calculated.