• 제목/요약/키워드: Hydrogen refueling system

검색결과 33건 처리시간 0.025초

캐스케이드 시스템 기반 수소 충전소를 이용한 대형 수소 연료 전지 차량 연속 충전 분석 (Analysis of Back-to-back Refueling for Heavy Duty Hydrogen Fuel Cell Vehicles Using Hydrogen Refueling Stations Based on Cascade System)

  • 심규석;박병흥
    • 한국수소및신에너지학회논문집
    • /
    • 제35권3호
    • /
    • pp.300-309
    • /
    • 2024
  • Hydrogen utilization in the transportation sector, which relies on fossil fuels, can significantly reduce greenhouse gas by using to hydrogen fuel cell vehicles, and its adoption depends performance of hydrogen refueling station. The present study developed a model to simulate the back-to-back filling process of heavy duty hydrogen fuel cell vehicles at hydrogen refueling stations using a cascade method. And its quantitatively evaluated hydrogen refueling station performance by simulating various mass flow rates and storage tank capacity combinations, analyzing vehicle state of charge (SOC) of vehicles. In the cascade refueling system, the capacity of the high-pressure storage tank was found to have the greatest impact on the reduction of filling time and improvement of efficiency.

개인적 위험도를 고려한 수소충전소의 안전계장기능 향상에 관한 연구 (A Study on the Improvement of Safety Instrumented Function of Hydrogen Refueling Station Considering Individual Risk)

  • 변윤섭
    • 한국수소및신에너지학회논문집
    • /
    • 제34권3호
    • /
    • pp.297-306
    • /
    • 2023
  • The frequency of fatal accidents that can occur at hydrogen refueling station was compared with the risk criterion for the general public suggested by the health and safety executive. If hydrogen refueling station meets the accident prevention facility standards presented in KGS Code FP216/217, it was confirmed that the risk of hydrogen refueling station was not at an unacceptable (intolerable) risk level. However, the risk of hydrogen refueling station due to small leak was analyzed as low as reasonably practicable. Therefore, methods for improving the safety instrumented function of hydrogen refueling station were reviewed. It was confirmed that the risk of hydrogen refueling station can be affected by the number of installed safety instrumentation system components, redundant architecture, mission time, proof test interval, etc. And methods for maintaining the risk of hydrogen refueling station at an acceptable risk level have been proposed.

수소 압축기 내장형 충전 탱크의 벨로우즈 강도 성능 향상을 위한 형상 설계 파라미터 연구 (Parametric Study of Shape Design for Strength Performance Enhancement of Bellows in Hydrogen Compressor-embedded Refueling Tank)

  • 김지형;송창용
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.39-46
    • /
    • 2024
  • As the development of hydrogen vehicles has accelerated in recent years, it is necessary to develop a storage tank for hydrogen fueling stations capable of high-pressure charging, and for this purpose, a new system with a compressor-embedded refueling tank is required. In this study, the parametric study of shape design based on strength performance evaluation was carried out to find the optimal shape design of bellows, the core component of compressor-embedded refueling tank for a newly developed hydrogen refueling station capable of high-pressure charging above 1,000 bar. The design factors for parametric study were contour shape and radius of bellows, and the performance factors were the maximum stress and the gap distance in the contact direction. In the shape design of the compressor bellows for hydrogen refueling station considered in this study, it was found that adjusting the contour radius is an appropriate design method to improve the compression performance and structural safety.

개질형 On-Site 수소충전소의 리스크 감소를 위해 요구되는 SIL 등급 달성 방안에 관한 연구 (A Study on the Achievement of Required Safety Integrity Level to Reduce Risk for SMR On-Site Hydrogen Refueling Stations)

  • 이진호;임재용
    • 한국안전학회지
    • /
    • 제35권6호
    • /
    • pp.1-8
    • /
    • 2020
  • In recent years, hydrogen has received much attention as an alternative energy source to fossil fuels. In order to ensure safety from the increasing number of hydrogen refueling stations, prevention methods have been required. In this regard, this study suggested an approach to reduce the risk of hydrogen refueling station by increasing Safety Integrity Level (SIL) for a Steam Methane Reformer (SMR) in On-Site Hydrogen Refueling Station. The worst scenario in the SMR was selected by HAZOP and the required SIL for the worst scenario was identified by LOPA. To verify the required SIL, the PFDavg.(1/RRF) of Safety Instrumented System (SIS) in SMR was calculated by using realistic failure rate data of SIS. Next, several conditions were tested by varying the sensor redundancy and proof test interval reduction and their effects on risk reduction factor were investigated. Consequently, an improved condition, which were the redundancy of two-out-of-three and the proof test interval of twelve months, achieved the tolerable risk resulting in the magnitude of risk reduction factor ten times greater than that of the baseline condition.

수소자동차의 연료주입라인용 Check Valve 내의 유동해석 (Flow Analysis of Check Valve for Hydrogen Vehicle Refueling Line)

  • 박경택;여경모;박태조;강병루
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.565-568
    • /
    • 2007
  • The high pressure hydrogen gas refueling system is required for fuel cell vehicle. In this paper, a commercial computational fluid dynamics (CFD) code, FLUENT is adopted to investigate the gas flow characteristics inside the check valve for various refueling and tank pressures. The results showed that the choking phenomena can occur for certain refueling pressures, therefore refueling processes should be divided by multiple stages. And a design method to prevent the seal departure problem which reported in CNG usages is required.

  • PDF

수소충전소용 프리쿨러를 위한 수소가스 냉각에 관한 연구 (Study on Cooling of Hydrogen Gas for the Pre-Cooler in the Hydrogen Refueling Station)

  • 이경한;구경모;유철휘;황갑진
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.237-242
    • /
    • 2019
  • In the hydrogen refueling station (HRS), it is need the pre-cooling system (PCS) to limit the inside temperature ($85^{\circ}C$) of the onboard thank (700 bar) and to charge the hydrogen at short time (within 3 minutes) to fuel cell electric vehicle (FCEV). From those safety reasons, the temperature of hydrogen gas must be controled $-33^{\circ}C$ to $-40^{\circ}C$ in PCS. The cooling test of the gaseous ($N_2$, He, $H_2$) was carried out using heat exchanger (pre-cooler) by indirect cooling and direct cooling method. It was confirmed that the temperature of hydrogen gas had below $-40^{\circ}C$ at below $-75^{\circ}C$ of chiller temperature in direct cooling.

고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가 (Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module)

  • 임상진;김민기;김수;이윤호
    • 해양환경안전학회지
    • /
    • 제29권1호
    • /
    • pp.76-85
    • /
    • 2023
  • 신재생에너지로서 수소에 대한 수요가 증가하고 있으나 기존의 화석 연료와 달리 수소는 연료 공급을 위한 전용 충전소가 필요하며, 이러한 인프라 확보를 위해서 수소충전소의 위험성 평가가 선행되어야 한다. 따라서 본 연구에서는 정성적 위험성평가와 정량적 위험성 평가로 구분하여 수소충전소에 대한 위험성평가를 수행하였다. 정성적 평가는 Hazard and Operability Analysis(HAZOP) 기법을 사용하여 Dispenser Module을 두 개의 Node로 평가하였으며, Criticality Estimation Matrix에 따라 Filter의 막힘으로 인한 사고와 고압 사고의 위험도가 High Level로 평가되었다. 정량적 위험성 평가는 Hydrogen Korea Risk Assessment Module(Hy-KoRAM)을 사용하여 화재의 형상과 피해영향범위를 나타냈고, 개인적 위험도와 사회적 위험도에 대한 평가를 수행하였다. 개인적 위험도는 수소충전소로부터 약 100m 떨어진 공공시설 부근까지 추가적인 안전조치가 고려되는 As Low As Reasonably Practicable(ALARP) 구간의 위험도를 보였고, 사회적 위험도 역시 약 10명의 사망자가 발생할 사고빈도가 1E-04/year로 도출되며 ALARP 구간 내에 나타났다. 정성적·정량적 위험성 평가 결과, 공정 단계의 추가적인 안전 조치와 수소충전소 부근의 제한구역 설정을 통하여 안전성 향상 방안을 제시하였다.

CFD 툴을 활용한 패키지형 수소충전시스템의 안전성 향상 연구 (A Study on the Safety Improvement by CFD Analysis for Packaged Type Hydrogen Refueling System)

  • 황순일;강승규;허윤실
    • 한국수소및신에너지학회논문집
    • /
    • 제30권3호
    • /
    • pp.243-250
    • /
    • 2019
  • In this study, to ensure the safety of the packaged hydrogen refueling system, the improvement plan was derived by using 3-dimensional CFD program (FLACS). We also confirmed the effectiveness of risk reduction and the suitability of safety standard. By ventilation performance evaluation according to the position of the vent, it demonstrated that the vent should be installed at the ceiling to safely ventilate without stagnation of the leaked gas. In case of ventilation system according to KGS standard, risk situation could be resolved after about 5 minutes in the worst leaked condition. The result showed that jet fire and explosion inside the packaged system could affect the surrounding facilities. This proves that the standard for installing flame detectors, emergency shut down system and protection wall is appropriate.

정량적 위험성평가를 통한 액화수소충전소 안전성 고찰 (A Study on the Safety of Liquefied Hydrogen Refueling Station through Quantitative Risk Assessment)

  • 박우일;강승규;이인우;양윤영;유철희
    • 한국가스학회지
    • /
    • 제27권4호
    • /
    • pp.116-122
    • /
    • 2023
  • 본 연구는 탄소중립 사회 실현을 위해 추진 중인 국제사회(한국, 미국, 유럽, 일본 등)의 수소경제 동향 분석과 더불어, 국민과 밀접한 핵심 수소 사용시설인 기존 구축·운영 중인 기체수소충전소와 향후 구축 예정인 액화수소충전소의 유형별 차이점을 비교·분석하였다. 또한, 정량적 위험성평가 프로그램인 SAFETI를 활용하여 액화수소충전소의 안전성을 분석하고, 조건부 허용영역인 개인적·사회적 위험도와 설비별 위험도 순위를 고려하여 설비 배치 등의 안전성 제고 방안에 대해 제안하였다.

수소 충전 시스템의 안전성 평가에 관한 연구 (A study on the safety assessment of Hydrogen refueling system)

  • 김태훈;오영달;이만수
    • 대한안전경영과학회지
    • /
    • 제16권4호
    • /
    • pp.167-173
    • /
    • 2014
  • Hydrogen energy is expanding in range for civil use together with development of pollution-free power sources recently, and it is judged that the use of hydrogen will increase more as a part of carbon dioxide reduction measures according to the Climatic Change Convention. Especially, it is thought that the securement of safety of the used dispenser will be the biggest obstacle in the use of high-pressure hydrogen because the hydrogen station is operated in a high pressure. This study found risks in the process and problems on operation by making use of HAZOP(6 kinds), a qualitative safety evaluation technique, and FMEA(5 kinds), a fault mode effect analysis, for the hydrogen charging system at a hydrogen gas station, derived 6 risk factors from HAZOP and 5 risk factors from FMEA, and prepared measures for it.