• Title/Summary/Keyword: Hydrogen Station

Search Result 225, Processing Time 0.023 seconds

Accidents Analysis of Domestic and Overseas Refueling Stations and Assessment of Dangerous Distance by Gas Leak (국내·외 충전소 사고 현황 분석 및 가스누출 피해거리 평가)

  • Kim, Hyelim;Kang, SeungKyu;Huh, YunSil
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.7-13
    • /
    • 2017
  • As environmental problems become a problem of survival, interest in eco-friendly energy is increasing to improve the environment. So, demand for eco-friendly fuels such as hydrogen, LPG and CNG is increasing. In particular, Korea, which relies on imports of most fuels, is investing in the development of hydrogen energy, which is favorable in terms of high production volume and energy independence. However, As demand grows every year, a variety of accidents occur in various ways, ranging from small leak incidents to massive fires and explosion, thus research needs to be done. So, in this study, compared and analyzed cases of hydrogen, LPG, CNG accidents occurring at domestic and overseas refueling stations. and various programs were used for assessing risk, estimated the flame length due to gas leakage and evaluated the dangerous distance.

Forecasting of Inspection Demand for Pressure Vessels in Hydrogen Fuel Cell Electric Vehicle using Bass Diffusion Model (Bass 확산모델을 이용한 수소전기차 내압용기 검사수요 예측)

  • Kim, Ji-Yu;Kim, Eui-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.3
    • /
    • pp.16-26
    • /
    • 2021
  • The global warming problem has arose, the supply eco-friendly vehicles such as HFCEVs is increasing around world and Korea is fully supporting subsidies, tax cut to form an initial market for HFCEVs. The key to the safety of HFCEVs is pressure vessels stored hydrogen, and although these pressure vessels must be inspection regularly, the existing inspection stations are insufficient to meet the demand for inspection. Therefore, it is important to establishment of pressure vessels inspection station for safety management of HFCEVs. In this study, it estimates innovation coefficient, imitation coefficient in Bass model by using electric vehicle sales data, and foretasted the supply of HFCEVs by region & the demand for inspection by region using the Bass diffusion model. As a result, the inspection demand for pressure vessels in HFCEVs in 2040 was 690,759 units, and it was confirmed 191 new inspection stations and 1,124 inspectors were needed to prepare for this.

Factors Relating to Induced Systemic Resistance in Watermelon by Plant Growth-Promoting Pseudomonas spp.

  • Lee, Yong-Hoon;Lee, Wang-Hyu;Lee, Du-Ku;Shim, Hyeong-Kwon
    • The Plant Pathology Journal
    • /
    • v.17 no.3
    • /
    • pp.174-179
    • /
    • 2001
  • The plant growth-promoting Pseudomonas strains, WR8-3 (Pseudomonas fluorescens), WR9-11 (Pseudomonas sp.) and WR9-16 (P.putida), which induced resistance systematically in watermelon to gummy stem rot were investigated on their induced systemic resistance(ISR)-related characteristics. The pyoverdine production was repressed in the standard succinate medium by increasing the concentration of $\textrm{FeCL}_3$. But the iron-binding ability on chrome azurol S agar media (CAS) was observed only in the strains, WR8-3 and WR9-16. When the two strains were mutated, the resulting iron-binding siderophore-negative mutants, WR8-3m and WR 9-16m, failed to promote the growth of watermelon and to induce resistance. The strains, WR8-3 and WR 9-16, slightly inhibited the growth of Didymella bryoniae at a low concentration of $\textrm{FeCL}_3$ on Kong's medium B, but not to exert control dffect. The strain WR9-11 showed antagonism in the concentration of $\textrm{FeCL}_3$ from 0 to $1,000\mu\textrm{M}$. When the crude lipoplysaccharide of each strain was treated in the rhizosphere of watermelon, mean lesion area was similar to that of the untreated control. The strains, WR9-11 and WR9-16 produced some level of hydrogen cyanide (HCN). Salicylic acid production was not detected in all of the strains.

  • PDF

A Study on the Improvement of Safety of Unloading Site by Comparison of Hydrogen Fluoride Leakage Accident (불화수소 누출사고 비교를 통한 하역작업장의 안전성 향상방안에 관한 연구)

  • Woo, Jongwoon;Shin, Changsub
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.32-38
    • /
    • 2018
  • The purpose of this study is to assess quantitatively the amount of leaks and the extent of dispersion in case of a leak at a hydrogen fluoride tank container unloading station, and to suggest a safety improvement plan to prevent recurrence of similar accidents. In 2012, Company H leaks 8 tonnes of tank containers with a maximum storage capacity of 18 Ton, causing it to become a social issue. As a result of calculation using Gaussian plume model, the concentration was estimated to be more than 20ppm from the leak point to 1,321 m radius. The leakage of hydrogen fluoride from the company R in 2014 was estimated to be 11.02 kg, of which 2.9 kg was treated by the scrubber. As a result of calculation using Gaussian plum model, the damage range with a concentration of 20ppm or more from the leak source was estimated to be 69 m in radius. As a result of comparing the above two accidents, it was found that the leakage amount was about 987 times different and the damaged site was more than 19 times different. Therefore, it was concluded that it was necessary to control the wearing of the protective equipment, the enclosure of the unloading site, the installation of the scrubber, and the emergency training to avoid the accidental leakage of a hydrogen fluoride from the unloading site.

An Analysis of Accessibility to Hydrogen Charging Stations in Seoul Based on Location-Allocation Models (입지배분모형 기반의 서울시 수소충전소 접근성 분석)

  • Sang-Gyoon Kim;Jong-Seok Won;Yong-Beom Pyeon;Min-Kyung Cho
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.2
    • /
    • pp.339-350
    • /
    • 2024
  • Purpose: This study analyzes accessibility of 10 hydrogen charging stations in Seoul and identifies areas that were difficult to access. The purpose is to re-analyze accessibility by adding a new location in terms of equity and safety of location placement, and then draw implications by comparing the improvement effects. Method: By applying the location-allocation model and the service area model based on network analysis of the ArcGIS program, areas with weak access were identified. The location selection method applied the 'Minimize Facilities' method in consideration of the need for rapid arrival to insufficient hydrogen charging stations. The limit distance for arrival within a specific time was analyzed by applying the average vehicle traffic speed(23.1km/h, Seoul Open Data Square) in 2022 to three categories: 3,850m(10minutes), 5,775m(15minutes), 7,700m(20minutes). In order to minimize conflicts over the installation of hydrogen charging stations, special standards of the Ministry of Trade, Industry and Energy applied to derive candidate sites for additional installation of hydrogen charging stations among existing gas stations and LPG/CNG charging stations. Result: As a result of the analysis, it was confirmed that accessibility was significantly improved by installing 5 new hydrogen charging stations at relatively safe gas stations and LPG/CNG charging stations in areas where access to the existing 10 hydrogen charging stations is weak within 20 minutes. Nevertheless, it was found that there are still areas where access remains difficult. Conclusion: The location allocation model is used to identify areas where access to hydrogen charging stations is difficult and prioritize installation, decision-making to select locations for hydrogen charging stations based on scientific evidence can be supported.

Dead-end Mode Operation of a Large Scale PEM Fuel Cell Stack (대면적 고분자전해질 연료전지의 데드엔드 운전)

  • Jeong, Jeehoon;Shin, Hyunkhil;Han, In-Su;Seo, Hakyu;Kim, Minsung;Cho, Sungbaek;Hur, Taeuk
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.83.1-83.1
    • /
    • 2010
  • A Dead-end mode operation is one of the best way to maximize the gas usage rate. But, some components of fuel cell stack like gas diffusion layer(GDL) or membrane can be damaged in dead-end mode operation. In this study, a Large Scale Polymer electrolyte membrane fuel cell(PEMFC) for a dead-end operation has been developed. The stack is composed with 4 cells which has over 400cm2 of active area. Hydrogen is used as a fuel, and oxygen is used as a oxidant. The dead-end operation performance was evaluated by a long-term dead-end mode operation. The fuel cell stack is operated over 1,500 hours in dead-end mode operating fuel cell test station. And the performance change of the fuel cell stack was investigated.

  • PDF

Design of adsorption bed for Compact H2 PSA process (Compact $H_2$ PSA 공정을 위한 흡착탑의 설계)

  • Lee Jang-Jae;Lee Sang-Jin;Moon Jong-Ho;Choi Dae-Ki;Lee Chang-Ha
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.60-68
    • /
    • 2006
  • 소수 station의 수소분리정제를 위한 compact형 PSA 공정을 연구하였다. 기존 PSA 공정의 흡착탑이 차지하는 시스템의 공간을 줄이기 위하여 하나의 흡착탑 안에 다른 흡착탑을 넣어 흡착탑이 차지하는 공간을 최소화하였으며, 흡착탑 간의 열교환이 효과적으로 일어나도록 설계하였다. 수소 혼합물에 대한 활성탄으로 충진된 dual bed에서의 수소 혼합물에 대한 흡/탈착 동특성 실험을 실시하였으며, 시간에 따른 농도와 온도의 변화를 측정하였다. 수소 혼합물로는 $H_2/CO/CH_4/CO_2$ (69:2:3:26 vol.%) 를 사용하였으며, 흡착유량은 7LPM, 흡착압력은 9atm 조건에서 운전하였다. Inner bed와 outer bed의 성능은 각각의 열전달 특성의 차이로 인하여 다르게 나타났으나, 단일탑의 동특성보다는 우수한 성능을 보이고 있었다. 따라서 개발된 dual bed는 적은 부지를 차지하면서도, 보다 우수한 수소 분리 성능을 보일 수 있는 PSA 공정에 응용될 수 있음을 확인하였다.

  • PDF

Design of adsorption bed for Compact $H_2$ PSA process (Compact $H_2$ PSA 공정을 위한 흡착탑의 설계)

  • Lee, Jang-Jae;Lee, Sang-Jin;Moon, Jong-Ho;Choi, Dae-Ki;Lee, Chang-Ha
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.5-8
    • /
    • 2006
  • 수소 station에서 수소분리정제를 위한 compact형 PSA 공정 설계를 위하여 활성탄으로 충진된 dual bed의 흡착동특성을 연구하였다. 기존 PSA 공정의 흡착탑이 차지하는 시스템의 공간을 줄이기 위하여 하나의 흡착탑 안에 다른 흡착탑을 넣어 흡착탑이 차지하는 공간을 최소화하고, 흡착탑 간의 열교환을 효과적으로 할 수 있도록 고안하였다. 수소 혼합물에 대한 dual bed에서의 흡착, 탈착 실험 실시하였으며, 시간에 따른 농도와 온도의 변화를 측정하였다. 수소 혼합물로는 $H_2/CO/CH_4/CO_2$ (69:2:3:26vol.%)를 사용하였으며, 흡착유량은 7LPM, 흡착압력은 9atm 조건에서 운전하였다. Inner bed와 outer bed의 수소 농도 파과곡선의 형태에 있어 차이를 보였으며, 이는 각 탑에서 열교환 효과로 인한 내부 온도 차이에 기인하여 발생하였다.

  • PDF

Uncertainties impact on the major FOMs for severe accidents in CANDU 6 nuclear power plant

  • R.M. Nistor-Vlad;D. Dupleac;G.L. Pavel
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2670-2677
    • /
    • 2023
  • In the nuclear safety studies, a new trend refers to the evaluation of uncertainties as a mandatory component of best-estimate safety analysis which is a modern and technically consistent approach being known as BEPU (Best Estimate Plus Uncertainty). The major objectives of this study consist in performing a study of uncertainties/sensitivities of the major analysis results for a generic CANDU 6 Nuclear Power Plant during Station Blackout (SBO) progression to understand and characterize the sources of uncertainties and their effects on the key figure-of-merits (FOMs) predictions in severe accidents (SA). The FOMs of interest are hydrogen mass generation and event timings such as the first fuel channel failure time, beginning of the core disassembly time, core collapse time and calandria vessel failure time. The outcomes of the study, will allow an improvement of capabilities and expertise to perform uncertainty and sensitivity analysis with severe accident codes for CANDU 6 Nuclear Power Plant.

An Experimental Study on Damage and Deformation Properties by Thickness of Concrete Impacted by High-Velocity Projectile (고속발사체 충격을 받은 콘크리트의 두께에 따른 손상 및 변형 특성에 관한 실험적 연구)

  • Kim, Yeong-Seon;Jo, Hong-Beom;Lee, Sang-Hyeon;Gi, Jeon-Do;Jeon, Hyeon-Su;Seok, Won-Gyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.203-204
    • /
    • 2022
  • This study reviewed the impact resistance properties according to the thickness of concrete as part of a research on the protection technology for high-velocity projectile that may occur during an explosion of small green energy facilities such as a hydrogen station and an energy storage system.

  • PDF