• Title/Summary/Keyword: Hydrogen House

Search Result 69, Processing Time 0.019 seconds

Development of an Application Program Code for Dryer Tower of Heat Transfer Analysis in Hydrogen Purification System (수소 정제 시스템의 건조 타워 열전달 해석을 위한 응용 프로그램 코드 개발)

  • SOOIN KWON;BYUNGSEOK JIN;GYUNGMIN CHOI
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.4
    • /
    • pp.334-341
    • /
    • 2023
  • The purity of hydrogen finally purified in the hydrogen purification process system is greatly influenced by the uniformity of the purification temperature of the dry tower. A in-house code that can be easily used by field designers has been developed to predict the capacity of the appropriate heat source and the time to reach the temperature of the dry tower. A code was developed to predict unsteady heat transfer using Visual Basic for Applications. To verify the developed code, a grid independence test was performed, and finally, calculations were performed for two cases. In the first case, the time for the temperature of the heater jacket to reach 360℃ was about 1,400 seconds when the supply heat source was 1,000 W. And in the second case, the time for the temperature of the heater jacket to reach 360℃ was about 710 seconds when the supply heat source was 2,000 W. It was confirmed that the developed code well describes the actual test data of the regeneration process of adsorption and desorption, and it is judged that the code developed in the design process of various capacity systems will be effectively applied to the heat capacity calculation in the future.

의약품 제조시설의 포름알데히드가스 훈증살균과 최근 실내무균화방법의 동향

  • 한국공기청정협회
    • Air Cleaning Technology
    • /
    • v.23 no.3
    • /
    • pp.34-43
    • /
    • 2010
  • In most productive facility of pharmaceutical companies, the fumigation using formaldehyde gas has been put into operation. Because formaldehyde gas is so bactericidal as to sterilize bacterial spore which can not be sterilized with usual disinfectants, it has been used for fumigation in many facilities such as facility of experimental animals, research institute and productive facility of pharmaceutical companies which are required to be high level of biological clean. However, the use of formaldehyde is recently under the strict management because of its causing of sick house and carcinogenesis. We introduce the conditions of sterilization using formaldehyde gas, the examples of sterilization using formaldehyde gas in a pharmaceutical manufacture and the problems of use of formaldehyde against environments and health. Further, we describe the characteristics and future subjects of the sterilization method using gasified oxidants such as hydrogen peroxide, peracetic acid and chlorine oxide.

  • PDF

A Study on Geothermal System Applicability of a Detached House (단독주택의 지열시스템 적용 가능성에 대한 연구)

  • Shin, Cheulsoo;Jang, Taeik
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.551-558
    • /
    • 2012
  • Due to high oil prices and global warming problems, researching an alternative energy source and decreasing the energy usage will be the key in the future. Unlike other alternative energy sources, geothermal energy is less dependent on the surrounding environment. Geothermal energy is the ideal energy source for buildings due to the simple and space saving installation. The system is semi permanent once it is installed and this will help reduce the energy usage in controlling the climate in buildings. Geothermal energy does not emit carbon dioxide and other gases that are harmful to the environment. Therefore geothermal energy will be the key in solving high oil prices and a decrease in fossil fuels by applying the geothermal energy system to homes to counter future energy crisis.

Preparation and Characterization of Silk and Mulberry/Silk Papers

  • Lee, Ki-Hoon;Kang, Gyung-Don;Oh, Han-Jin;Ki, Chang-Seok;Kim, Jong-Wook;Park, Young-Hwan
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.13 no.1
    • /
    • pp.45-50
    • /
    • 2006
  • Papers were prepared from cut cocoons and mulberry branches, which are byproducts from sericulture industry. The long filament of silk should be cut into appropriate length in order to prepare paper and this was achieved by chemical method. By a mixture of sodium hydroxide and sodium carbonate solution, the silk filaments were cut into short fibers (less than 1 mm in length). Since the short silk fibers (sSf) could not bind each other by itself, starch and poly(ethylene oxide)(PEO) were added as a bonding agent. When starch and PEO were used in a ratio of 3:7, the silk papers had optimum mechanical properties for paper. Fibers from the skin of mulberry branches (MBF) were added to sSf to enhance the mechanical properties of pure silk paper. Bleaching of MBF was performed with a mixture of hydrogen peroxide and sodium silicate. The mechanical properties were greatly enhanced and the optimum blend ratio of MBF and sSf were 7:3. The mulberry/silk paper has good absorption property against formaldehyde, and therefore, the paper could be applied as a wall paper for preventing the sick house syndrome.

Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House (바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과)

  • Song, J.I.;Choi, H.L.;Choi, H.C.;Kwon, D.J.;Yoo, Y.H.;Jeon, J.H.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.3
    • /
    • pp.195-200
    • /
    • 2007
  • Management of odors is essential to swine industry in the Republic of Korea. This study was conducted to evaluate the odor removal efficiency of biofilter ducting systems. Rice straw and auto clave concrete(ALC) were used as filter medium. The ventilation fans(5 units, diameter: 500 mm) at the side wall of a growing pig housing were connected to a biofilter using a duct. The size of a biofilter is $2.5{\times}2{\times}1.2(W{\times}L{\times}H)$. The air velocities at the 300 mm above rice straw and ALC were 0.77 and 0.56 m/s, respectively. Ammonia concentration at the outlet of rice straw and ALC media were 2 and 3 ppm, respectively. Dust concentrations were also measured. The dust concentrations of rice straw and ALC were 93, $32\;mg/m^3$, respectively. There was no significant difference between filter mediums in terms of carbon dioxide concentrations(rice straw: 320, ALC: 270 mg/l). The concentration of hydrogen sulfide was stable over the experimentation. The actual concentrations of hydrogen sulfide were 4, 3 and 3 ppm at the days of 7, 21 and 36, respectively. These results suggest that biofilter ducting systems may remove odors from pig house effectively.

  • PDF

Effect of pH on Hydrogen Fermentation of Food Waste with Livestock Wastewater (음식물쓰레기 수소발효 시 pH 영향 및 축산폐수와의 혼합 발효)

  • Jang, Hae-Nam
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.5-9
    • /
    • 2016
  • In the modern industrial society, huge amount of organic wastes have exceeded the society's self-cleaning capability, caused pollution of the whole environment, including water quality, soil, and the air, and become a big burden of waste treatment. Moreover, the emission of green house gases brought by the continual combustion of fossil fuels has facilitated the global warming. The simultaneous effect of initial and operational pH on $H_2$ yield was expressed using mathematical equation and optimized. The optimal initial and cultivation pH was 7.50 and 6.01, respectively. Addition of livestock wastewater to food waste substantially decreased the amount of alkali requirement and also improved the $H_2$ fermentation performance.

Effects of Magnetite added with Metallic Oxide on the Decomposition Reaction of Carbon Dioxide (CO$_2$ 분해 반응에서 금속 산화물이 첨가된 $Fe_2O_4$의 영향)

  • Kim, Seung-Ho;Park, Young-Goo
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.32-37
    • /
    • 1998
  • The Carbon Dioxide is the gas, which causes green house effects, unusual changes in the weather, destruction of the life. Almost every nation in the world is trying to search the countermeasure to this poisonous gas. I synthesized $Fe_3O_4$ and NaOH, in order to decompose the Carbon Dioxide. Among the particles synthesizing $Fe_3O_4$, I chose the equivalent ratio 1.00 which can decompose the Carbon Dioxide best, and fixed that equivalent ratio and added the 0.005-3.00 mole percentage of NiCl$_2$ and synthesized $Fe_3O_4$. I studied the decomposition of the Carbon Dioxide and methanized reaction, by measuring its crystal structure, thermochemistrical character and specific surface area. In decomposing the Carbon Dioxide, I used oxygen-deficit Magnetite which I produced by injecting the hydrogen gas into the synthesized sample. I observed the methanization reaction by raising the temperature of sample up to 650$\circ$C and having it reacted with the hydrogen gas. The decomposition of the Carbon Dioxide was added 0.005, 0.03, 0.05 mole percentage of NiCl$_2$ was more effective than pure $Fe_3O_4$. All sample in which the decomposition of the Carbon Dioxide took place produced the methane gas.

  • PDF

A Simulation based Study on the Economical Operating Strategies for a Residential Fuel Cell System (시뮬레이션 기반 가정용 연료전지 시스템의 경제적 운전전략에 관한 연구)

  • Hwang, Su-Young;Kim, Min-Jin;Lee, Jin-Ho;Lee, Won-Yong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.2
    • /
    • pp.104-115
    • /
    • 2009
  • In case of residential fuel cell system, it is significant to stably supply heat and power to a house with high efficiency and low cost for the successful commercialization. In this paper, the control strategy analysis has been performed to minimize the total cost including capital and operating cost of the residential fuel cell system. The proposed analysis methodology is based on the simulator including the efficiency models as well as the cost data for fuel cell components. The load control strategy is the key factor to decide the system efficiency and thus the cost analysis is performed when the fuel cell system is operated for several different load control logics. Additionally, annual efficiency of the system based on the seasonal load data is calculated since system efficiency is changeable according to the electric and heat demand change. As a result, the hybrid load control combined electricity oriented control and heat oriented control has the most economical operation.

Ammonia and Hydrogen Sulfide Removal from Swine House Exhaust Air Using a Dip Injection Wet Scrubber

  • Shin, Myeongcheol;Lee, Seunghun;Wi, Jisoo;Ahn, Heekwon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.50 no.6
    • /
    • pp.615-622
    • /
    • 2017
  • This study was conducted to evaluate the odor reduction efficacy of the dip injection wet scrubber (DIWS) using tap water as washing fluid. The $NH_3$ and $H_2S$ removal efficiency of 7 day batch operated DIWS was evaluated twice over a total of 14 days of experiment. The $NH_3$ removal efficiency ranged from 26 to 37%. The $H_2S$ removal efficiency was between 22 and 30%. The pH of the washing fluid maintained below 8 and the $NH_4{^+}$ concentration tended to keep constant around 350 ppm after 5 days of washing-fluid replacement. Therefore, the 5-day washing fluid replacement interval is more preferable than the 7-day interval. The $NH_4{^+}$ concentration and the electrical conductivity (EC) showed a high correlation. The EC measurement can be used as an alternative to conventional $NH_4{^+}$ concentration measurement method for real time monitoring of washing fluid condition.

Energy Management Technology Development for an Independent Fuel Cell-Battery Hybrid System Using for a Household (가정용 독립 연료전지-배터리 하이브리드 에너지 관리 기술 개발)

  • YANG, SEUGRAN;KIM, JUNGSUK;CHOI, MIHWA;KIM, YOUNG-BAE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.2
    • /
    • pp.155-162
    • /
    • 2019
  • The energy management technology for an independent fuel cell-battery hybrid system is developed for a household usage. To develop an efficient energy management technology, a simulation model is first developed. After the model is verified with experimental results, three energy management schemes are developed. Three control techniques are a fuzzy logic control (FLC), a state machine control (SMC), and a hybrid method of FLC and SMC. As the fuel cell-battery hybrid system is used for a house, battery state of charge (SOC) regulation is the most important factor for an energy management because SOC should be kept constant every day for continuous usage. Three management schemes are compared to see SOC, power split, and fuel cell power variations effects. Experimental results are also presented and the most favorable strategy is the state machine combined fuzzy control method.