• Title/Summary/Keyword: Hydraulic energy

Search Result 1,193, Processing Time 0.025 seconds

Development of Cotton Farming and Transformation of Rural Area in Sanliurfa Prefecture, Turkey (터키 샹르울파주 목화농업의 전개와 지역사회의 변화)

  • Kang, Sukkyeong
    • Journal of the Korean Geographical Society
    • /
    • v.48 no.1
    • /
    • pp.87-111
    • /
    • 2013
  • Regional disparities between eastern and western regions is the most of serious problem for balanced regional development in Turkey. The Southeastern Anatolia Project (GAP) is being implemented to eliminate these regional development disparities. The work that was initially planned as predominantly for hydraulic energy production to utilize water resources of the Tigris and Euphrates rivers more effectively was later transformed into an integrated multi-sector regional development project. This study noted that this region had very limited cash crop production because of the constraints of semi-arid climate of the southeastern region, however, later, it has changed Turkey's major cotton producing region since Southeastern Anatolia Project carried out. Therefore, this study investigated background, process, and content of the Southeastern Anatolia Project with respect to high cotton productivity in this region and examined the dynamic changes of cotton productivity in this region. In addition, Sanliurfa prefecture is one of the main development axes of the Southeastern Anatolia Project, because government investments are concentrated on this prefecture. Therefore, this study examined the background and process of cotton farming growth in this prefecture. In 2011, Sanliurfa prefecture produced 37.6% of Turkey's total cotton production. This is mainly due to agricultural infrastructure expansion such as land consolidation, irrigation, roads and farm roads. Also, it is one of the main factor that subsidies paid to farmers for cotton cultivation. The introduction of irrigation has dramatically changed the direction of seasonal migration of this area. Prior to irrigation, this area had a serious social issue about out-migration for seasonal labor to other areas. However, the introduction of irrigation made this area that changed to in-migration and intramigration for cotton cultivation. Irrigation water is supplied to farmers through the WUAs (Water User Associations) that handed over irrigation water management, operation from DSI (General Directorate of State of Hydraulic Works). However, the WUAs are under the influence of Ashiret, a traditional feudal social structure. Because of this reason, it does not have an efficient management for farmers. Also, it is one of the reasons that this area does not have autonomous farmer organization.

  • PDF

Distribution and properties of intertidal Surface Sediments of Kyeonggi Bay, West Coast of Korea (경기만 조간대 표층퇴적물의 분포와 특성)

  • LEE, CHANG-BOK;YOO, HONG-RHYONG;PARK, KYUNG-SOO
    • 한국해양학회지
    • /
    • v.27 no.4
    • /
    • pp.277-289
    • /
    • 1992
  • Kyeonggi Bay, a macrotidal coastal embayment in the Yellow Sea coast of central korea, is fringed by vastly developed tidal flats. About 400 surface sediment samples were collected from the intertidal and subtidal zones of Kyeonggi Bay for a study of the sediment distribution pattern and the surface sediment characteristics of this environment. The kyeonggi Bay surface sediment becomes progressively finer in the shoreward direction, from offshore sand to shoreward silty sand and sandy silt. This shoreward-fining trend is repeated again on the tidal flat and, as a consequence, a grain-size break occurs near the low-water line which separates the intertidal area from the subtidal one. The intertidal and subtidal sediments differ from each other in textural characteristics such as mean grain size and skewness and this can be interpreted to result from differences in hydraulic energy and morphology between the two environments. The mineral and chemical compositions of the Kyeonggi Bay sediments are largely controlled by the sediment grain size. Smectite was nearly absent in the clay mineral assemblage of Kyeonggi Bay sediment. The contents of Co, Cu and Ni were high in the Banweol tidal flat, which suggests a continuous process of accumulation of these metals. the intertidal environment appears to respond rapidly to artificial coastal modifications, the effects of which should be taken into consideration when planning a dam construction or coastal reclamation.

  • PDF

Application of Flood Prevention Measures Using Detailed Topographic Data of River and Lowland (하천-제내지의 상세 지형자료를 이용한 수해방지대책 적용)

  • LEE, Jae-Yeong;HAN, Kun-Yeun;KEUM, Ho-Jun;KO, Hyun-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.1
    • /
    • pp.15-29
    • /
    • 2020
  • Recently, the incidence of flooding in Korea has decreased by the measures by central and local governments, however the scale of damage is increasing due to the improvement of living standard. One of the causes of such flood damage is natural causes such as rainfall exceeding the planned frequency of flood control under climate change. In addition, there are artificial causes such as encroachment of river spaces and management problems in upstream basins without consideration of downstream damage potential by regional development flood. In this study, in order to reduce the inundation damage caused by flooding of river, the situation at the time of inundation damage was reproduced by the detailed topographic data and 2D numerical model. Therefore, the effect of preparing various disaster prevention measures for the lowland was simulated in advance so that quantitative evaluation could be achieved. The target area is Taehwa river basin, where flooding was caused by the flooding of river waters caused by typhoon Chaba in October 2016. As a result of rainfall-discharge and two-dimensional analysis, the simulation results agree with the observed in terms of flood depth, flood arrival time and flooded area. This study examined the applicability of hydraulic analysis on river using two-dimensional inundation model, by applying detailed topographic data and it is expected to contribute to establish of disaster prevention measures.

Computational Method for Rate of Overtopping Using Time Dependent Mild-Slope Equation (시간의존 완경사방정식을 이용한 월파량 산정 방법)

  • Kwak, Moon-Su;Lee, Hong-Gyu;Park, Sung-Yoon;Pyun, Chong-Kun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.4
    • /
    • pp.372-382
    • /
    • 2006
  • Most of the conventional breakwaters impermeable breakwaters which block seawater exchange between the outside and inside of the harbors. The blocking of seawater exchange may cause pollution of water in harbors. To solve the water pollution problem, various kinds of seawater exchange breakwaters have been proposed. Their types can be classified into the current type which uses tidal current, and the overtopping type which uses the wave energy. The overtopping type breakwaters require a discharge coefficient to calculate the rate of overtopping into the harbor. The present study is to compute the rate of overtopping with introduction of a correct discharge coefficient and to evaluate the effect of the overtopping type breakwater on the water qualify inside a harbor. The rate of overtopping was computed by using Forchheimer formula with time dependent mild-slope equation for various wave conditions. The formula has been generally used to calculate the overflow discharge in steady state river flows. The discharge coefficient, which is the key parameter of the calculation, was determined by a series of hydraulic model tests. The present scheme was applied to the seawater exchange section of the western breakwater of Jeju New Harbor's and the efficiency of that section was examined. The calculated results showed that the rate of overtopping into the harbor reached about $27.5m^3/s$ in the wave condition (wave height 3.7 m, wave period 8.5s, and wave direction NNW).

Channel Structure and Header Design of Printed Circuit Heat Exchanger by Applying Internal Fluid Pressure (유체 내압을 고려한 인쇄기판형 열교환기의 채널구조 및 헤더 설계)

  • Kim, Jungchul;Shin, Jeong Heon;Kim, Dong Ho;Choi, Jun Seok;Yoon, Seok Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.767-773
    • /
    • 2017
  • Printed Circuit Heat Exchanger (PCHE) has an advantage for exchanging thermal energy between high-pressure and high-temperature fluids because its core is made by diffusion bonding method of accumulated metal thin-plates which are engraved of flow channel. Moreover, because it is possible that the flow channel can be micro-size hydraulic diameter, the heat transfer area per unit volume can be made larger than traditional heat exchanger. Therefore, PCHE can have higher efficiency of heat transfer. The smaller channel size can make the larger heat transfer area per unit volume. But if high pressure fluid flows inside the channel, the channel wall can be deformed, the structure and shape of flow channel and header have to be designed appropriately. In this study, the design methodology of PCHE channel in high pressure environment based on pressure vessel codes was investigated. And this methodology was validated by computational analysis.

A Study on Corrosion Properties of Reinforced Concrete Structures in Subsurface Environment (지중 환경하에서의 철근콘크리트 구조물의 부식 특성 연구)

  • Kwon, Ki-jung;Jung, Haeryong;Park, Joo-Wan
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.79-85
    • /
    • 2016
  • A concrete silo plays an important role in subsurface low- and intermediate-level waste facilities (LILW) by limiting the release of radionuclides from the silo geosphere. However, due to several physical and chemical processes the performance of the concrete structure decreases over time and consequently the concrete loses its effectiveness as a barrier against groundwater inflow and the release of radionuclides. Although a number of processes are responsible for degradation of the silo concrete, it is determined that the main cause is corrosion of the reinforcing steel. Therefore, the time it takes for the silo concrete to fail is calculated based on two factors: the initiation time of corrosion, defined as the time it takes for chloride ions to penetrate through the concrete cover, and the propagation time of corrosion. This paper aims to estimate the time taken for concrete to fail in a LILW disposal facility. Based on the United States Department of Energy (DOE) approach, which indicates that concrete fails completely once 50% of the volume of the reinforcing steel corrodes, the corrosion propagation time is calculated to be 640 years, which is the time it takes for corrosion to penetrate 0.640 cm into the reinforcing steel. In addition to the corrosion propagation time, a diffusion equation is used to calculate the initiation time of corrosion, yielding a time of 1284 years, which post-dates the closure time of the LILW disposal facility if we also consider the 640 years of corrosion propagation. The electrochemical conditions of the passive rebar surface were modified using an acceleration method. This is a useful approach because it can reduce the test time significantly by accelerating the transport of chlorides. Using instrumental analysis, the physicochemical properties of corrosion products were determined, thereby confirming that corrosion occurred, although we did not observe significant cracks in, or expansion of, the concrete. These results are consistent with those of Smartet al., 2006 who reported that corrosion products are easily compressed, meaning that cracks cannot be discerned by eye. Therefore, it is worth noting that rebar corrosion does not strongly influence the hydraulic conductivity of the concrete.

Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions (지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교)

  • Kim, Jin-Sung;Song, Sung-Ho;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.23 no.4
    • /
    • pp.389-398
    • /
    • 2013
  • Studies of the thermal properties of various rock types obtained from several locations in Korea have revealed significant differences in thermal conductivities in the thermal response test (TRT), which has been applied to the design of a ground-source heat pump system. In the present study, we aimed to compare the thermal conductivities of the samples with those obtained by TRT. The thermal conductivities of soil and rock samples were 1.32W/m-K and 2.88 W/m-K, respectively. In comparison, the measured TRT value for thermal conductivity was 3.13W/m-K, which is 10% higher than that of the rock samples. We consider that this difference may be due to groundwater flow because abundant groundwater is present in the study area and has a hydraulic conductivity of 0.01. It is natural to consider that the object of TRT is to calculate the original thermal conductivity of the ground, following the line source theory. Therefore, we conclude that the TRT applied to a domestic standing column type well is not suitable for a line source theory. To solve these problems, values of thermal conductivity measured directly from samples should be used in the design of ground-source heat pump systems.

Characteristics of Organics Treatment Using White-rot Fungus Biofilm of Atmospheric Exposed Type (대기노출형 백색부후균 생물막을 이용한 유기물 처리특성)

  • Lee, Soon-Young;Kang, Ki-Cheol;Won, Chan-Hi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.5
    • /
    • pp.491-499
    • /
    • 2008
  • It is really urgent to develop wastewater treatment system which is economically efficient, occupies small area for buildup, can be easily operated, discharges small amount of sludge due to the more strict water quality standard, the expensive water and energy cost and so on. This study on treatment of wastewater including nonbiodegadable materials using white-rot fungus biofilm were designed to investigate the submerged type of biofilm, hydraulic retention times, recycle rates, and module turning times. Removal efficiencies of fully exposed biofilm type in atmosphere are similar to submerged biofilm of aeration type. The optimum conditions of white-rot fungus biofilm of fully exposed type in atmosphere are HRT 3$\sim$4 hr, recycle rate 6$\sim$10 Q, module turning times 0.5$\sim$2 times/min. At this time, removal efficiencies of organics were COD$_{Cr}$ 65.0$\sim$69.9%, NBDCOD 70.4$\sim$72.7%, BOD$_5$ 88.8$\sim$90.1%, SS 84.2$\sim$90.4%. Moreover average effluent concentration of BOD$_5$(8.9 mg/L) satisfied water quality standard of heavy water(BOD$_5$ less than 10 mg/L) but concentration of NBDCOD(29.6 mg/L) was higher than water quality standard of heavy water(NBDCOD less than 20 mg/L).

A study on the HTS-NAA/γ-spectrometry for the analysis of alpha-particle emitting impurities in silica (고순도 실리카중 알파방출 불순물 분석을 위한 HTS-NAA/γ-spectrometry 연구)

  • Lee, Kil Yong;Yoon, Yoon Yeol;Cho, Soo Young;Yang, Myung Kwon;Shim, Sang Kwon;Kim, Yongje;Chung, Yong Sam
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.5-12
    • /
    • 2005
  • It has been established that soft error of high precision electronic circuits can be induced by alpha particles emitted from the naturally occurring radioactive impurities such as U, and Th. As the electronic circuits have recently become lower dimension and higher density, these alpha-particle emitting radioactive impurities have to be strictly controlled. The aim of this study is to develop of NAA (Neutron Activation Analysis) and gamma-spectrometry to improve the analytical sensitivity and precision of U and Th. A new NAA method has been established using the HTS (Hydrulic transfer system) irradiation facility which has been used to produce radioisotopes for industries and medicines instead of the PTS (pneumatic transfer system) irradiation facility which has been used in general NAA. When the ultratrace impurities have to be analyzed by NAA, background gamma-ray spectra induced from $^{222}Rn$ and its progenies in air is serious problem. This unstable background has been eliminated or stabilized by the use of a nitrogen purging system. Ultra trace amounts of U (0.1 ng/g) and Th (0.01 ng/g) in high purity silica used for EMC could be analyzed by the use of HTS-NAA and low background gamma-spectrometry.

A Study for Lifespan Prediction of Expansion by Temperature Status (온도상태에 따른 신축관 이음의 수명예측에 관한 연구)

  • Oh, Jung-Soo;Lee, Bong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.424-429
    • /
    • 2018
  • In this study, an expansion joint that is susceptible to waterhammer was tested for its vibration durability. The operation data for the hydraulic actuator was the expansion length of the expansion joint when the waterhammer occurred. In the case of the vibration durability test, the internal temperature status of the expansion joint was assumed to be a stress factor and a lifespan prediction model was assumed to follow the Arrhenius model. A test was carried out by increasing the internal temperature status at $30^{\circ}C$, $50^{\circ}C$, and $65^{\circ}C$. By a linear transformation of the lifespan data for each temperature, a constant value and activation energy coefficient was induced for the Arrhenius equation and verified by comparing the value of a lifetime prediction model with the experimental value at $85^{\circ}C$. The failure modes of the ongoing or finished test were leakage, bellows separation, and internal deformation. In the future, a composite lifespan prediction model, including two more stress factors, will be developed.