• 제목/요약/키워드: Hybrid insulation pole-transformer

검색결과 5건 처리시간 0.024초

저손실형 복합절연 주상변압기 개발 및 단락특성에 관한 연구 (A Study on the Development of Low-loss Type Hybrid Insulation Pole Transformers and)

  • 민윤홍;유호근;배선기;김호철;이윤재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.607-612
    • /
    • 2002
  • This paper presents the first domestic model product of hybrid Insulation low-loss type pole transformer, with increased overload ability, increased life, reduced loss, focusing improved short-circuit characteristics. The capacity of this transformer is 100 KVZ, rates first voltage 13200 V and secondary voltage 230/115 type. The volume of model transformer that was produced in high temperature using hybrid insulation can be reduced to 10-20% in comparison with that of present transformer with the same capacity. In this paper, we did short-circuit test and tested general characteristics of model transformer. In addition, we suggested design application new concept and methods thorough this experiment.

  • PDF

혼합절연을 이용한 초저손실급 주상변압기 개발에 관한 연구 (A Study on the Development of Super Low-loss Type Pole Transformer Using the Hybrid Insulation)

  • 민윤홍;신대철
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.84-93
    • /
    • 2007
  • 주상변압기는 고객에게 직접 전력을 공급하는 설비로서 전력공급의 안정성확보를 위한 중요한 기자재 중 하나이다. 하지만 제조결함에 의한 3년 이내의 초기고장 또는 13년이 초과 사용한 후의 열화고장이 빈번히 발생하고 있어 변압기 품질분석을 통한 신뢰성이 개선된 주상변압기 개발이 필요하다. 본 논문에서는 열적, 기계적, 전기적으로 성능이 향상된 새로운 모델의 혼합절연 주상변압기를 개발하였다. 변압기의 기계적, 열적특성을 향상시키기 위한 혼합절연 방식에 대한 설계 및 제작방법을 제시하고 과부하시험을 시행하여 순간최대부하에 대응할 수 있도록 과부하내량 160[%] 까지 증가시킬 수 있음을 확인하였다. 또한 본 논문에서는 100[kVA] 1대를 시제품으로 제작하여 단락강도시험과 변압기 관련 절연시험을 시행하여 전자기계력의 분석과 단락강도설계 향상 방안에 대하여 설명하고 이와 관련하여 연구한 결과에 대해 논하였다.

주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용 (The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers)

  • 이병성;송일근;이재봉;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

배전용 변압기 절연유의 특성 비교 평가 (The Evaluation of Characteristics for Insulating Oil Using the Distribution Transformer)

  • 이병성;박영근;김동명;김필환;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.97-99
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF

광유 및 식물성 절연유에서 절연지의 열적 열화 특성 평가 (The Evaluation of Thermal Aging for Insulation Paper with Mineral and Vegetable Oil)

  • 이병성;송일근;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1558-1560
    • /
    • 2004
  • Liquid-immersed pole transformers have utilized an insulation system consisting of natural cellulose-based materials and mineral oil for many years. If the transformers are installed with the abruptly changing load over limitation, its insulation materials are apt to unexpected aging with high temperature. Therefore we have been conscious of developing a transformer that is more thermally stable then conventional types. To measure temperature distribution in the winding of conventional and newly designed transformers, temperature sensors were installed fordirect reading of oil and conductor temperatures at transformers. And we conducted accelerating aging test for these transformers. The measuring data had made use of the design to hybrid insulation system. Also we could find the possibility of this insulation system to apply in pole mounted transformers.

  • PDF