• Title/Summary/Keyword: Hybrid Power Unit

Search Result 123, Processing Time 0.025 seconds

Modularization and Application of Hybrid Renewable Energy Process in Seosan Area (서산 지역에서의 혼합 신재생에너지 공정의 모듈화 및 적용 연구)

  • JEONG SOO AHN;MIN HYEONG KANG;CHEON KIM;KYEONG SIK SEO;SEUNG HYEON KWAK;YU JIN CHOI;TAE JIN PARK;JAE CHEOL LEE
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.2
    • /
    • pp.212-225
    • /
    • 2023
  • This study presents a modularized process of a hybrid renewable energy system that combines photovoltaic power and wind power to supply stable power in a unit area (1 km2). The water electrolysis process and fuel cells process also contributes to the supply of the stable power. The entire system can constantly supply power of 4.39 MW/km2. Actual meteorological data is used for simulation.

Hybrid Artificial Immune System Approach for Profit Based Unit Commitment Problem

  • Lakshmi, K.;Vasantharathna, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.959-968
    • /
    • 2013
  • This paper presents a new approach with artificial immune system algorithm to solve the profit based unit commitment problem. The objective of this work is to find the optimal generation scheduling and to maximize the profit of generation companies (Gencos) when subjected to various constraints such as power balance, spinning reserve, minimum up/down time and ramp rate limits. The proposed hybrid method is developed through adaptive search which is inspired from artificial immune system and genetic algorithm to carry out profit maximization of generation companies. The effectiveness of the proposed approach has been tested for different Gencos consists of 3, 10 and 36 generating units and the results are compared with the existing methods.

Development of the Ka-band 20watt SSPA (Solid State Power Amplifier) Using a Spatial Combiner (공간결합기를 이용한 Ka대역 20W급 SSPA 개발)

  • Choi, Young-Rak;Lee, Jong-Woo;Lee, Su-Hyun;An, Se-Hwan;Lee, Man-Hee;Kim, Hong-Rak
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.1
    • /
    • pp.231-238
    • /
    • 2019
  • In this paper, we have studied how to improve the amplifiers efficiency by minimizing the combining loss when several unit power amplifiers are combined to obtain high output power. Specifically, we have developed Ka-band Spatial Combining Amplifier. The fabricated Spatial Combining Amplifier is a Ka-band 20W class SSPA, which uses a 5W class unit amplifier module 8EA designed using a GaN bare die. We also combined The unit amplifier module using 8-way spatial divider and combiner with a hybrid radial structure. The output combining loss of the fabricated spatial coupler is about 0.334dB, which is about 92.6% efficiency. In this paper, we developed a Spatial Combining Amplifier with a maximum saturation output of 10W and a power addition efficiency of over 15%. As a result, we achieved the maximum saturation output of 30W and the power addition efficiency of 19%.

Main Systems Composing Hybrid Tram (하이브리드 트램의 시스템 구성)

  • Chang, Se-Ky;Lee, Kang-Won;Bae, Chang-Han
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.730-734
    • /
    • 2007
  • National projects on renewable energy and new energy are driven more actively than ever in many countries for the exhaustion of fossil fuel energy from the turn of the century. Such activities began to spread out in railway industry with centering around west European countries. Electric energy is generated on the hybrid vehicle itself, which contributes to reduction of the cost for construction of the infrastructure required for the supply of electric power. Hybrid tram is mainly composed of propulsion system to control electric energy, automatic guidance system to control steering and operation, and central vehicle unit to control and monitor major electronic devices. Generation and supply of electric power are made by the combination of engine generator and battery, or fuel cell and super capacitor.

  • PDF

Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit (2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Nam, Goung-Hyun;Lee, Na-Young;Han, Tae-Hee;Choi, Choi-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF

A Development of Parallel Type Hybrid Drivetrain System for Transit Bus Part 3 : Optimal Driving Control Algorithm (버스용 병렬형 하이브리드 동력전달계의 개발(III) 제 3 편;최적 주행 제어 알고리즘)

  • 조한상;이장무;박영일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.6
    • /
    • pp.182-197
    • /
    • 1999
  • Described in this paper is an optimal driving control algorithm which focused on the improvement of fuel economy and the minimization of pollutant emissions in the parallel type hybrid drivertrain system for transit bus. For the energy balance among components such as engine, induction machine and buttery, the algorithm for power split ration determine is proposed. When it is implemented in the hybrid electric control unit(HECU) , using the sub-optimal method and the approximate technique , it is possible to save the memory , to shorten the calculation time, and to achieve the efficient driving actually. A Shift strategy for automated manual transmission is the other side of the driving control algorithm. It enables to select the optimal gear by using several shift maps which were predefined from the proposed method in this paper, As a results of driving simulation, it is proved that these algorithms make the hybrid drivetrain system to reduce fuel consumption and emissions considerably and to have the ability to the efficient use of battery.

  • PDF

Characteristics of high energy density hybrid capacitor using metal oxide electrode (금속산화물 전극을 사용한 고 에너지밀도 하이브리드 커패시터 특성)

  • Yoon, Hong-Jin;Shin, Yoon-Sung;Lee, Jong-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • The electrochemical performances of an asymmetric hybrid capacitor were investigated using $LiFePO_4$ as the positive electrode and active carbon fibers(ACF) as the negative electrode. The electrochemical behaviors of a nonaqueous hybrid capacitor were characterized by constant current charge/discharge test. The specific capacitance using $LiFePO_4$/ACF electrode turned out to be $0.87F/cm^2$ and the unit cell showed excellent cycling performance. This hybrid capacitor was able to deliver a specific energy as high as 178 Wh/kg at a specific power of 1,068 W/kg.

The Evaluation of an Electric Hybrid Power System for the High Endurance Drone (장기체공 드론용 하이브리드 전기 추진시스템 성능 평가)

  • Gang, Byeong Gyu;Kim, Keun-Bae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.539-544
    • /
    • 2022
  • This research shows the test performance of a 6 kW-scale hybrid electric power system for the high endurance drone. The power system is composed of a two-stroke reciprocal engine, starter-generator and battery, and they are integrated as one power unit. The engine is designed to provide the house for holding the starter-generator at the end of a crankshaft in turn the engine and starter-generator can maintain the same speed during the operational period. In this way, the generated power is readily controlled by just manipulating an engine throttle movement. Moreover, the starter-generator can initiate an engine operation with an aid of battery power until the combustion process becomes stabilized. In consequence, integration mechanism between an engine and generator is simplified, which results in weight reduction achieved. The duty of back-up battery is to provide a starting power to generator via a system controller in addition to covering momentarily power shortage. Therefore, the electric power system is vindicated to provide 6 kW power through a ground test.

Power Assist Control for Walking Aid by HAL Based on Phase Sequence and EMG

  • Lee, Suwoong;Yoshiyuki Sankai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.46.1-46
    • /
    • 2001
  • This paper describes a control method of hybrid power assistive system for lower body, HAL, with the techniques of Phase Sequence and the application of EMG. Our objective is to attain the power assist control of motion in the lower body effectively with these two methods. The Phase Sequence which performs basic motion controls of HAL is the method that a motion, the Task, is accomplished by dividing each motion into the unit named Phase and ...

  • PDF

Design and Development Trends of Solar Thermal Power Generation in Korea (국내의 태양열발전 기술개발 동향 및 설계)

  • Kang, Yong-Heack;Kim, Jin-Soo;Kim, Jong-Kyu;Lee, Sang-Nam;Yu, Chang-Kyun;Yoon, Hwan-Ki
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.658-661
    • /
    • 2007
  • KIER have been developing high-temperature solar technology, especially the solar thermal power generation system, since the early of 1990s. In 1994, the first research on high temperature solar technology started with PTC technology. At the moment the most advanced 10kW dish system is under demonstration for 10kW solar thermal power generation. Test results showed about 19.2% solar to electricity average efficiency. Another research activities of KIER is hybrid power generation. For hybridization, solar and LFG(landfill gas) are used. Another hybrid solar system is with solar chemical reaction. In this system, power unit is gas turbine, and the heat content of fuel(like natual gas) is upgraded by solar energy through chemical reaction. The latest project on solar thermal power generation is for 1 MW power tower system. This is the Korea-China Joint project.

  • PDF