• Title/Summary/Keyword: Hybrid Mesh

Search Result 147, Processing Time 0.025 seconds

Noise and Vibration Analysis of a Flat Plate by using Modal Expansion Technique (모드 확장 기법을 이용한 평판의 진동.소음 해석)

  • 김관주;이봉노
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.654-662
    • /
    • 1998
  • To predict the radiating noise from the vibrating surface, it is required to know the velocity distribution of vibrating surface exactly as possible as it can. Although it can be obtained by finite element method, their accuracy is limited by theuncertainty of preparing input data such as material propoerties, damping, excitation, and the actual boundary conditions. Experimental values are accurate but are seldom available as many asthe data points compared to FEM mesh. Therefore, hybrid method of experiment and finite element method, called modal expansion technique, is investigated for the preparatin of accurate element method at specified frequencies and for the verification of this scheme, related experiment is performed. In high frequency range above 2000 Hz, piezo-electric material is used as an actuator.

  • PDF

Numerical Simulation of 2-D Lid-Driven Cavity Plow at High Reynolds numbers (높은 Re수에서의 2차원 Lid-Driven 캐비티유동의 수치해석)

  • Myong H. K.;Kim J. E.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.153-158
    • /
    • 2005
  • Numerical simulations of two-dimensional steady incompressible lid-driven flow in a square cavity are presented to verify the validity of a new solution code(PowerCFD) with unstructured grids. The code uses the non-staggered(collocated) grid approach which is very popular for incompressible flow analysis because of its numerical efficiency on the curvilinear or unstructured grids. Solutions are obtained for configurations with a Reynolds number as high as 10,000 with both rectangular and hybrid types of unstructured grid mesh. Interesting features of the flow are presented in detail and comparisons are made with benchmark solutions found in the literature. It is found that the code is capable of producing accurately the nature of the lid-driven cavity flow at high Reynolds numbers.

  • PDF

Prediction of 2-Dimensional Temperature Distribution in Power Transformer Using F.E.M. (유한요소법을 이용한 전력용 변압기의 2차원 온도분포 예측)

  • Lee, Jeong-Geun;Kim, Joong-Kyoung;Joo, Soo-Won;Hahn, Sung-Chin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.751-752
    • /
    • 2006
  • 최근 전력용 변압기의 고효율, 소형화 추세에 따라 권선의 단위면적당 열발생률이 증가하고 있으며 이는 변압기의 수명과 단락사고에 직결되는 중요한 문제로 대두되고 있다. 본 논문에서는 단순화한 2차원 전력용 변압기 모델의 계산 시간을 줄이기 위해 복합격자(Hybrid mesh) 생성기법을 적용하여 모델링하고 유한요소법을 이용한 자계해석으로 권선과 철심의 Joule's loss를 계산하였다. 계산된 열원으로 전력용 변압기의 최고점의 온도와 열적 특성을 파악하고자 CFD algorithm을 이용하여 변압기 내부의 온도분포를 예측하였다.

  • PDF

Authentication Scheme in Wireless Mobile Multi-hop Networks (무선 모바일 멀티 홉 네트워크에서의 인증 기법 고찰 및 개선)

  • Lee, Yong;Lee, Goo Yeon
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.43-51
    • /
    • 2007
  • In mobile multi-hop wireless networks, the authentication between a base station and a mobile multi-hop node, between multi-hop nodes, and between user a station and a multi-hop node is needed for the reliable and secure network operation. In this paper, we survey various authentication schemes which can be considered to be adopted in mobile multi-hop wireless networks and propose a concept of novel mutual authentication scheme applicable to mobile multi-hop network architecture. The scheme should resolve the initial trust gain problem of a multi-hop node at its entry to the network, the problem of rogue mobile multi-hop node and the problem of hop-by-hop authentication between multi-hop nodes. Effectively, the scheme is a hybrid scheme of the distributed authentication method and the centralized authentication method which are considered to be deployed in the wireless ad-hoc network and the wireless network connected to wired authentication servers, respectively.

  • PDF

Computational Analysis of EFP Design (EFP 설계의 전산 해석)

  • 최서원;강호철;홍종태;이상길
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.2 no.2
    • /
    • pp.110-116
    • /
    • 1999
  • Supersonic flows over an EFP(explosively formed projectile) have been calculated by a high-order conservation law scheme and two-layer $$textsc{k}$-{\varepsilon}$ model on hybrid viscous unstructured mesh. To verify the accuracy and robustness of the developed code, two basic flows about airfoils are computed and results are compared with existing experimental data and computational results. The comparisons confirm the validity of the code and justify our use for such a highly supersonic and viscous flow over a blunt body. Complex flow features of supersonic flows over an EFP are clearly captured and show agreements with the flow visualization. From the interaction of oblique shocks near the surface of flare, flow structures, that were not identified by previous experimental results, are discovered as a result of present computation.

  • PDF

Study for Effective Cooling of Ni-MH Battery Module Using Forced Air Flow (공기 유동에 따른 Ni-MH 배터리 모듈의 효과적인 냉각에 관한 연구)

  • Ahn, Chi-Yeong;Kim, Tae-Sin;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.253-260
    • /
    • 2011
  • In this study, computational simulation was performed for thermal management of modules consisting of 10 batteries. Simplified structure and equivalent thermal resistance network was applied to maintain the thermal properties. Verification test of the mesh were in progress to ensure the reliability of 2.6 mm in the narrow gap between the battery, resulting in at least three divided mesh between the shape of the grid was required. Type of air from rear of the module, type of air from top of the module and type of air from bottom of the module were applied and effective cooling methods are discussed based on the location of fan and air intake of the modules. Maximum temperature and temperature differences of modules that directly affect the performance of the module were compared, and also behavior of the fluid was confirmed by comparing the air flow. The best maximum temperature is shown type of air from bottom of the module to $40.27^{\circ}C$ and type of air from top of the module shows smallest temperature difference $0.73^{\circ}C$.

Implementation of Prosumer Management System for Small MicroGrid (소규모 마이크로그리드에서 프로슈머관리시스템의 구현)

  • Lim, Su-Youn;Lee, Tae-Won
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.6
    • /
    • pp.590-596
    • /
    • 2020
  • In the island areas where system connection with the commercial power grid is difficult, it is quite important to find a method to efficiently manage energy produced with independent microgrids. In this paper, a prosumer management system for P2P power transaction was realized through the testing the power meter and the response rate of the collected data for the power produced in the small-scale microgrids in which hybrid models of solar power and wind power were implemented. The power network of the microgrid prosumer was composed of mesh structure and the P2P power transaction was tested through the power meter and DC power transmitter in the off-grid sites which were independently constructed in three places. The measurement values of the power meter showed significant results of voltage (average): 380V + 0.9V, current (average): + 0.01A, power: 1000W (-1W) with an error range within ±1%. Stabilization of the server was also confirmed with the response rate of 0.32 sec. for the main screen, 2.61 sec. for the cumulative power generation, and 0.11 sec for the power transaction through the transmission of 50 data in real time. Therefore, the proposed system was validated as a P2P power transaction system that can be used as an independent network without transmitted by Korea Electric Power Corporation (KEPCO).

A multiphase flow modeling of gravity currents in a rectangular channel (사각형 수로에서 중력류의 다상흐름 수치모의)

  • Kim, Byungjoo;Paik, Joongcheol
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.10
    • /
    • pp.697-706
    • /
    • 2019
  • A multiphase flow modeling approach equipped with a hybrid turbulence modeling method is applied to compute the gravity currents in a rectangular channel. The present multiphase solver considers the dense fluid, the less-dense ambient fluid and the air above free surface as three phases with separate flow equations for each phase. The turbulent effect is simulated by the IDDES (improved delayed detach eddy simulation), a hybrid RANS/LES, approach which resolves the turbulent flow away from the wall in the LES mode and models the near wall flow in RANS mode on moderately fine computational meshes. The numerical results show that the present model can successfully reproduce the gravity currents in terms of the propagation speed of the current heads and the emergence of large-scale Kelvin-Helmholtz type interfacial billows and their three dimensional break down into smaller turbulent structures, even on the relatively coarse mesh for wall-modeled RANS computation with low-Reynolds number turbulence model. The present solutions reveal that the modeling approach can capture the large-scale three dimensional behaviors of gravity current head accompanied by the lobe-and-cleft instability at affordable computational resources, which is comparable to the LES results obtained on much fine meshes. It demonstrates that the multiphase modeling method using the hybrid turbulence model can be a promising engineering solver for predicting the physical behaviors of gravity currents in natural environmental configurations.

A Particle Tracking Method for the Lagrangian-Eulerian Finite Element Method in 3-D Subsurface System (3차원 지표하 시스템에서 Lagrangian-Eulerian 유한요소법에 대한 입자추적 알고리즘)

  • Lee, Jae-Young;Kang, Mee-A
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.205-215
    • /
    • 2009
  • The conventional numerical models to analyze flow in subsurface porous media under the transient state usually generate numerical oscillation and unstability due to local flux domain for critical cases such as infiltration into initially dry soil during rainfall period. In this case, it is required refined mesh and small time step, but it decrease efficiency of computation. In this study, numerical unstability in discontinuity domain is removed by applying particle tracking algorithm to simulate unsteady subsurface flow with inflow boundary condition. Finally the hybrid LE FEM improving numerical stability is proposed. The hypothetical domains with unsteady uniform and nonuniform flow field were used to demonstrated algorithm verification. In comparison with analytic solution, we obtained reasonable results and conducted simulation of hypothetical 3-D recharge/pumping area. The proposed algorithm can simulate saturated/unsaturated porous media with more practical problems and will greatly contribute to accuracy and stability of numerical computation.

A Latency Optimization Mapping Algorithm for Hybrid Optical Network-on-Chip (하이브리드 광학 네트워크-온-칩에서 지연 시간 최적화를 위한 매핑 알고리즘)

  • Lee, Jae Hun;Li, Chang Lin;Han, Tae Hee
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.131-139
    • /
    • 2013
  • To overcome the limitations in performance and power consumption of traditional electrical interconnection based network-on-chips (NoCs), a hybrid optical network-on-chip (HONoC) architecture using optical interconnects is emerging. However, the HONoC architecture should use circuit-switching scheme owing to the overhead by optical devices, which worsens the latency unfairness problem caused by frequent path collisions. This resultingly exert a bad influence in overall performance of the system. In this paper, we propose a new task mapping algorithm for optimizing latency by reducing path collisions. The proposed algorithm allocates a task to a certain processing element (PE) for the purpose of minimizing path collisions and worst case latencies. Compared to the random mapping technique and the bandwidth-constrained mapping technique, simulation results show the reduction in latency by 43% and 61% in average for each $4{\times}4$ and $8{\times}8$ mesh topology, respectively.