• Title/Summary/Keyword: Human vibration characteristics

Search Result 147, Processing Time 0.027 seconds

Nonlinearity of Biodynamic Response to Shock-Type Vertical Whole-Body Vibration (쇼크타입 수직방향 전신진동에 대한 생체동역학적 반응의 비선형성)

  • Ahn Se-Jin;Griffin Michael J.;Yoo Wan-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.145-151
    • /
    • 2007
  • Impulsive excitation on vehicle produces shock-type vibration on the seat, which has major frequencies and damping ratios dependent on the characteristics of the suspension, the tire, the seat cushion and so on. The response of single degree of freedom model to a half-sine force input was considered as simple shock-type vibration signal. Quasi-apparent-mass for fifteen subjects was measured with the shock-type vibration generated on a rigid seat mounted on the simulator, so its nonlinearity was apparently found over 6.3 Hz according to the difference of magnitude of the shock.

Analysis on a Hip Joint System of New RGO Using Accelerometers (가속도계를 이용한 왕복보행보조기의 고관절 시스템 해석 -인체 진동해석과 FEM 해석을 중심으로-)

  • 김명회;장대진;장영재;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.882-887
    • /
    • 2003
  • This paper presented a design and control of a new RGO(reciprocating gait orthosis)and its simulation. The new RGO was distinguished from the other one by which had a very light-weight and a new RGO(reciprocating gait orthosis) system. The vibration evaluation of the hip joint system on the new RGO(reciprocating gait orthosis)was used to access by the 3-axis accelerometer with a low frequency vibration of less than 30 ㎐. The gait of the new RGO depended on the constrains of mechanical kinematics and the initial posture. The stability of dynamic walking was investigated by analyzing the ZMP (zero moment point) of the new RGO. It was designed according to the human wear type and was able to accomodate itself to the environments of S.C.I. Patients. The joints of each leg were adopted with a good kinematic characteristics. To analyse joint kinematic properties, we made the hip joint system of FEM and the hip joint system by 1-axis and 3-axis Accelerometers.

  • PDF

Study About the Evaluation of Driving Stability Using 3-axis Accelerometer Test (3축 가속도 시험을 통한 도로 노면의 주행 안정성 평가에 대한 연구)

  • Lee, Dong-Hyun;Kim, Ji-Won;Mun, Sung-Ho;Jeong, Won-Seok
    • International Journal of Highway Engineering
    • /
    • v.14 no.3
    • /
    • pp.141-149
    • /
    • 2012
  • This paper attempts to evaluate driving stability by the vibration of human body. The purpose of this research is to establish an evaluation methodology for controling the quality of road surface. The study was conducted to investigate the relationship between road surface profiles (IRI, International Roughness Index) and the fatigue caused by the vibration of human body. Furthermore, 3-axis acceleration in driving vehicles was examined based on sampling sections under various road conditions. The acceleration value of frequency bands were analyzed by the characteristics of road surface, and realized the range of human influence by conditions and type of road surface with ISO-2631 standards. In general, more human fatigue by vehicle vibration was appeared in concrete pavements with high IRIs based on the analysis from given test data. Whereas, The SMA asphalt pavement and the diamond grinded concrete pavement reduce the human fatigue.

Comparison of the Standard Floor Impact Source with the Human Impact Source (표준충격원과 실충격원의 특성 비교)

  • Lee, Pyoung-Jik;Jeong, Jeong-Ho;Jeon, Jin-Yong;Park, Jun-Hong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.804-807
    • /
    • 2005
  • The characteristics of the standard floor impact sources and the human impact source were investigated. First, the mechanical impedance of the each source was evaluated. Second, the impact force exposure levels and impact sounds level driven by the each source were measured. The results showed that the mechanical impedance and impact force exposure level of the impact ball are the most similar to those of the human impact source among the standard impact sources.

  • PDF

DYNAMICS OF HUMAN BODY RESPONDING TO SHOCK-TYPE VERTICAL WHOLE-BODY VIBRATION (수직방향 충격 진동에 대한 인체동역학적 특성)

  • Ahn, Se-Jin;Yoon, Seong-Ho;Chang, Ik-Soon;Kim, Joong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.546-550
    • /
    • 2008
  • Impulsive excitation on vehicles produces shock-type vibration on the seat, usually which has major frequencies and damping ratios dependent on the characteristics of the suspension, the tire, the seat cushion and so on. The response of single degree of freedom model to a half-sine force input was considered as simple shock-type vibration signal. The quasi-apparent-mass for fifteen subjects was obtained with the shock-type vibration generated on the rigid seat, so its nonlinearity was found over 6.3 Hz according to the difference of magnitude of the shocks.

  • PDF

Comparison of Performance of the Exciter and Impact Hammer Test for Dynamic Characteristics Analysis of Floor Slabs (건물바닥 슬래브의 동특성 분석을 위한 가진기와 Impact Hammer의 성능 비교)

  • Ahn, Sang-Kyung;Moon, Yeong-Jong;Oh, Jung-Keun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.117-120
    • /
    • 2007
  • The floor slabs of building structures are often subjected to the periodic force which is induced by vibrating machines or human activity(walking, jumping, running etc). These periodic forces cause excessive oscillation. In order to examine the dynamic characteristics of floor slabs, the dynamic characteristics test is accomplished. Generally, the Impact Hammer and Dynamic Exciter test is used to dynamic characteristics test. But the Impact Hammer test is not suitable to apply in building slabs. In this paper, It compared the performance of the Exciter and Impact Hammer test for dynamic characteristics analysis of floor slabs.

  • PDF

A Study on the Control of the Floor Vibration in a Research Building (연구소(硏究所) 건물(建物)의 슬래브 진동(振動) 성능개선(性能改善) 연구(硏究))

  • Baik, In-Whee;Kang, Ho-Sub;Sohn, Young-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • A vibration in the building occurs by influences of the facility equipment and the structural system. As the building recently becomes higher and bigger, the vibration in the floor slab is issued. Specially, the vibration with $4{\sim}8Hz$ frequency is harder to control than any other range of frequency. This vibration easily affects human sensibility and often makes the resonance phenomenon by corresponding with the floor slab's natural frequency when people and heavy equipments move. Moreover, the permission regulations for the vibration of the building are established by building's purposes. However, it is not subdivided in detail and sometimes ambiguous to each client. Even though the vibration could cause negative influences in a research building, there is not the vibration criterion for a research building. Therefore, it is necessary to set up its own vibration criterion with the client before building and to keep checking this vibration criterion under the construction. This study proposes the reasonable control methods and the vibration criterion for floor slab's vibration which are adapted to the R4-project. The R4-project is a research building and a high-rise building also. Accordingly, this study could help to the next similar project in the design and the construction phase.

Discrete Optimization for Vibration Design of Composite Plates by Using Lamination Parameters

  • Honda, Shinya;Narita, Yoshihiro;Sasaki, Katsuhiko
    • Advanced Composite Materials
    • /
    • v.18 no.4
    • /
    • pp.297-314
    • /
    • 2009
  • A design method is proposed to optimize the stacking sequence of laminated composite plates for desired vibration characteristics. The objective functions are the natural frequencies of the laminated plates, and three types of optimization problems are studied where the fundamental frequency and the difference of two adjacent frequencies are maximized, and the difference between the target and actual frequencies is minimized. The design variables are a set of discrete values of fiber orientation angles with prescribed increment in the layers of the plates. The four lamination parameters are used to describe the bending property of a symmetrically laminated plate, and are optimized by a gradient method in the first stage. A new technique is introduced in the second stage to convert from the optimum four lamination parameters into the stacking sequence that is composed of the optimum fiber orientation angles of all the layers. Plates are divided into sub-domains composed of the small number of layers and designed sequentially from outer domains. For each domain, the optimum angles are determined by minimizing the errors between the optimum lamination parameters obtained in the first step and the parameters for all possible discrete stacking sequence designs. It is shown in numerical examples that this design method can provide with accurate optimum solutions for the stacking sequence of vibrating composite plates with various boundary conditions.

Estimation of Anti-vibration Glove Performance Considering the Vibration Characteristic of Power Tool through Development of Flexible Palm Adapter (Flexible Palm 어댑터의 개발을 통한 동력 공구의 진동 특성을 고려한 방진장갑의 성능 평가)

  • Song, Chi-Mun;Jang, Han-Kee;Hong, Seok-In;Chai, Jang-Bom
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.2
    • /
    • pp.217-224
    • /
    • 2009
  • This study aims to show the guideline to select optimal anti-vibration gloves for specific power tools to prevent hazardous vibration to human body. It is most desirable for the correct evaluation of handtransmitted vibration form the power tool handle to measure the acceleration between the handle surface and the hand palm as recommended in ISO 5349-1. First, the accurate acceleration measurement device was developed of which the thickness and weight were less than 6 mm and 12 g respectively so that it can be placed between the handle and the palm without any inconvenience during the measurement. Finally, using the device we estimated anti-vibration glove performances considering the frequency characteristics of generated vibration by the power tool.

Fabrication of Vibration-Driven Electromagnetic Energy Harvester with Spring-Less and Its Characteristics (스프링이 없는 진동형 전자기식 에너지 하베스터의 제작과 그 특성)

  • Ryu, Kyeong-Il;Chung, Gwiy-Sang
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.249-253
    • /
    • 2011
  • This paper describes the fabrication and characteristics of vibration-driven electromagnetic energy harvester without spring to use at low frequency like a human body motion. The implemented energy harvester consists of NdFeB magnets, copper coil. The optimization of induced voltage was done by the various widths of coil, number of the turns, size of fixed and moving magnets and thicknesses of the cylinder. The fabricated energy harvester is capable of producing up to 15.0 $V_{pp}$ for basic model and 28.80 $V_{pp}$ for improved model at 5.0 Hz resonance frequency and 0.75 g acceleration level. The basic model and improved model are provided a maximum power of 6.375 mWand 25.831 mW at 1 KHz of load resistance in rectifier circuit.