• Title/Summary/Keyword: Human Body Communication

Search Result 356, Processing Time 0.025 seconds

Reducing Power Consumption of Wireless Capsule Endoscopy Utilizing Compressive Sensing Under Channel Constraint

  • Saputra, Oka Danil;Murti, Fahri Wisnu;Irfan, Mohammad;Putri, Nadea Nabilla;Shin, Soo Young
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.2
    • /
    • pp.130-134
    • /
    • 2018
  • Wireless capsule endoscopy (WCE) is considered as recent technology for the detection cancer cells in the human digestive system. WCE sends the captured information from inside the body to a sensor on the skin surface through a wireless medium. In WCE, the design of low-power consumption devices is a challenging topic. In the Shannon-Nyquist sampling theorem, the number of samples should be at least twice the highest transmission frequency to reconstruct precise signals. The number of samples is proportional to the power consumption in wireless communication. This paper proposes compressive sensing as a method to reduce power consumption in WCE, by means of a trade-off between samples and reconstruction accuracy. The proposed scheme is validated under channel constraints, expressed as the realistic human body path loss. The results show that the proposed scheme achieves a significant reduction in WCE power consumption and achieves a faster computation time with low signal error reconstruction.

Characterization of Body Shadowing Effects on Ultra-Wideband Propagation Channel

  • Pradubphon, Apichit;Promwong, Sathaporn;Chamchoy, Monchai;Supanakoon, Pichaya;Takada, Jun-Ichi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.219-222
    • /
    • 2004
  • There are several factors that disturb an Ultra-Wideband (UWB) radio propagation in an indoor environment such as path loss, shadowing and multipath fading. These factors directly affect the quality of the received signal. In this paper, we investigated the influence of the human body shadowing on UWB propagation based on measured wireless channel in an anechoic chamber. The characteristics of the UWB channel including the transmitter and the receiver antenna effects are acquired over the frequency bandwidth of 3${\sim}$11 GHz. The major factors such as the power delay profile (PDP), the angular power distribution (APD), the pulse distortion and the RMS delay spread caused by the human body shadowing are presented.

  • PDF

An Evaluation Method of Taekwondo Poomsae Performance

  • Thi Thuy Hoang;Heejune Ahn
    • Journal of information and communication convergence engineering
    • /
    • v.21 no.4
    • /
    • pp.337-345
    • /
    • 2023
  • In this study, we formulated a method that evaluates Taekwondo Poomsae performance using a series of choreographed training movements. Despite recent achievements in 3D human pose estimation (HPE) performance, the analysis of human actions remains challenging. In particular, Taekwondo Poomsae action analysis is challenging owing to the absence of time synchronization data and necessity to compare postures, rather than directly relying on joint locations owing to differences in human shapes. To address these challenges, we first decomposed human joint representation into joint rotation (posture) and limb length (body shape), then synchronized a comparison between test and reference pose sequences using DTW (dynamic time warping), and finally compared pose angles for each joint. Experimental results demonstrate that our method successfully synchronizes test action sequences with the reference sequence and reflects a considerable gap in performance between practitioners and professionals. Thus, our method can detect incorrect poses and help practitioners improve accuracy, balance, and speed of movement.

Efficient Interference Cancellation Scheme for Wireless Body Area Network

  • Bae, Jung-Nam;Choi, Young-Hoon;Kim, Jin-Young;Kwon, Jang-Woo;Kim, Dong-In
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.167-174
    • /
    • 2011
  • In this paper, we propose and simulate an efficient interference cancellation scheme with an optimal ordering successive interference cancellation (SIC) algorithm for ultra wideband (UWB)/multiple-input-multiple-output (MIMO) systems in a wireless body area network (WBAN). When there are several wireless communication devices on a human body, multiple access interference (MAI) usually occurs. To mitigate the effect of MAI and achieve additional diversity gain, we utilize SIC with an optimal ordering algorithm. A zero correlation duration (ZCD) code with robust MAI capability is employed as a spread code for UWB systems in a multi-device WBAN environment. The performance of the proposed scheme is evaluated in terms of the bit error rate (BER). Simulation results confirm that the BER performance can be improved significantly if the proposed interference cancellation scheme and the ZCD code are jointly employed.

Funology Body : Classified Application System Based on Funology and Philosophy of the Human Body (Funology Body : Funology와 '몸의 철학' 이론을 바탕으로 한 어플리케이션 분류 검색 체계 연구)

  • Kihl, Tae-Suk;Jang, Ju-No;Ju, Hyun-Sun;Kwon, Ji-Eun
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.635-646
    • /
    • 2010
  • This article focuses on Funology and a new classified application system based on concept of language and thought which are formed by body experience. It is defined by Funology Body as that. Funology Body is classifying and searching system which are consisted of a body, world (environment), and device tool. The body is sectioned by Brain, Eyes, Ears, Nose, Mouth, Hand, Torso, Feet, and Heart according as parts of the human body. This allows intuiting and experience searching as making classified system connected to the application relationship with concept of an each part of body. The Brain of the body is sub-classified by Book, Account, Business, Memory, Education, Search, and Aphorism to imply the application with thought. The Eyes take Video, Photography, and Broadcast for visibility. The Ears is categorized as Music, Instrument, Audio, and Radio for hearing. The Nose gets Perfume, Smell for olfactory sense. The Mouth is sectioned by Food, SNS, Chatting, Email, and Blog for eating and communication. The Hand sorts into Games, Kits, and Editing to handle, create, and play. The Torso is grouped by Health, Medical, Dance, Sport, Fashion, and Testyuorself related by protecting internal and meaning of the body core. The Feet is classified by Travel, Transportation, Map, and Outdoor for moving and concept of expanding the terrain. The Heart is consisted of Fear, Anger, Joy, Sadness, Acceptance, Disgust, Expectation, and Surprise for a human feeling. Beyond that, the World takes News, Time, Weather, Map, Fortune, and Shop, and Device tool gets Interface, Utilities. The Funology Body has a unique characteristic of giving intuitive and sensuous pleasure and reflection of users' attitude and taste for changing application flexibly.

  • PDF

Active Implantable Device Technology Trend: BCI Application Focus (능동형 임플란터블 디바이스 기술동향: BCI 응용 중심)

  • Lee, S.Q.;Byun, C.W.;Kim, Y.G.;Park, H.I.
    • Electronics and Telecommunications Trends
    • /
    • v.32 no.6
    • /
    • pp.27-39
    • /
    • 2017
  • A variety of medical devices are utilized to repair or help injured body functions after accidental injury(such as a traffic accident), population aging, or disease. Such medical devices are being actively researched and developed in portable form, skin patchable type, and further, implantable form. In the future, active implantable medical devices for neuro and brain sciences are expected to be developed. Active implantable medical devices that detect brain signals and control neurology for a wider understanding of human cognition and nerve functions, and for an understanding and treatment of various diseases, are being actively pursued for future use. In this paper, the core elements of implantable devices that can be applied to neuro and brain sciences are classified into electrode technologies for bio-signal acquisition and stimulation, analog/digital circuit technologies for signal processing, human body communication technologies, wireless power transmission technologies for continuous device use, and device integration technologies to integrate them. In each chapter, the latest technology development trends for each detailed technology field are reviewed.

Implementation of Face Animation For MPEG-4 SNHC

  • Lee, Ju-Sang;Yoo, Ji-Sang;Ahn, Chie-Teuk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.141-144
    • /
    • 1999
  • MPEG-4 SNHC FBA(face and body animation) group is going to standardize the MPEG-4 system for low-bit rate communication with the implementation and animation of human body and face on virtual environment. In the first version of MPEG-4 standard, only the face object will be implemented and animated by using FDP (face definition parameter) and FAP(facial animation parameter), which are the abstract parameters of human face for low-bit rate coding. In this paper, MPEG-4 SNHC face object and it's animation were implemented based on the computer graphics tools such as VRML and OpenGL.

A Time Synchronization Protocol for Wireless Body Sensor Networks (무선 인체 센서 네트워크용 시각 동기화 프로토콜)

  • Bae, Shi-Kyu
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.5 no.6
    • /
    • pp.127-134
    • /
    • 2016
  • WBSN (Wireless Body Sensor Network), also called WBAN (Wireless Body Area Networks) generally, is a kind of WSN (Wireless Sensor Network) applications, which is composed of the various sensor nodes residing in human body embodied or in wearable way. The measured data at each sensor node in WBSN requires being synchronized at sink node for exact analysis for status of human body, which is like WSN. Although many time synchronization protocols for WSN has been already developed, they are not appropriate to WBSN. In this paper, a new time synchronization protocol for WBSN considering the characteristics of WBSN is proposed. The proposed scheme is not only simple, but also consumes less power, leading to increasing network life time. We will show that the proposed scheme is appropriate to WBSN by evaluating its performance by simulation.

Performance of UWB System in dispersive human body (분산 인체채널에서의 UWB시스템 성능분석)

  • Woo, Sun-Keol;Won, Hyun-Jun;Yang, Hoon-Gee
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.45-50
    • /
    • 2005
  • This paper make an analysis of UWB Communication System. In case endoscope, medical equipment, is applied to UWB, We could study through body-channel that frequency transmitted of received signal is differ from wireless in the existing air. It suggested TR-UWB form, non-coherent received method in dispersion-medium like humans bodies by accomplishing ability analysis of BPM, TR, BER of Differential, UWB Communication modulation and demodulation form.

  • PDF

Development of a transcutaneous system for implantable bio-signal measurement (생체신호계측을 위한 체내 이식형 무선송수신 시스템 개발)

  • Lee, Seung-Ha
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2008
  • In order to measure bio-signals, it is desirable to build a fully implantable system which connects directly to neural pathways or body tissue. A design scheme for fully implementable measurement system is proposed in this paper. Consisting of an implanted module and an external system, the proposed scheme delivers power and data between the two modules. The external module sends power via inductive link using a simple H-bridge type oscillator. Also, the implanted module sends measured data to the external system utilizing R/F communication technique at a frequency of ISM band. A stable communication and operation is achieved as the two types of channels are separated. Implemented in a compact size enough to be implanted in human body, the system exhibits good performance in experimental studies.