• Title/Summary/Keyword: Hot-Spot Analysis

Search Result 255, Processing Time 0.028 seconds

Characteristic Analysis of Hot Spot Temperature according to Cooling Performance Variation of Natural Ester Transformer (식물성 절연유 변압기의 냉각특성 변화에 따른 최고점온도 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • Natural ester has a higher biodegradability, flash and fire points, and a greater permittivity compared to conventional mineral oils. However, natural ester also has a higher pour point, viscosity, and water content. These characteristics hamper circulation and the electrical properties of oil-filled transformer. Thus, this paper applied electromagnetic-thermal-flow coupled analysis method to predict temperature distribution inside 154kV single phase power transformer using natural ester. It modeled in the actual appearance for the tank and winding of the power transformer to improve the accuracy of analysis and applied heat flow analysis that considered hydromechanics and heat transfer at the same time. It calculated the power loss, the main cause of temperature rise, from winding and core with electromagnetic analysis then used for the heat source for the heat flow analysis. It then compared the reasonability of result of measurement analysis based on the result acquired from temperature rise test using FBG sensor on the power transformer.

PHOTOMETRIC STUDIES OF THE CONTACT BINARY BV DRACONIS (접촉쌍성 BV Draconis의 측광학적 연구)

  • 이재우;한원용;김천휘
    • Journal of Astronomy and Space Sciences
    • /
    • v.16 no.2
    • /
    • pp.227-240
    • /
    • 1999
  • We performed CCD photometric observations of W UMa type contact binary BV Dra during eight nights from May 1996 to June 1999 using 61cm telescope at Sobaeksan Optical Astronomy Observatory, and completed BV R light curves of the system. From our observations, we derived nine new times of minimum lights (five timings for primary eclipse, four for secondary) and determined new light elements with the times of minima observed since 1999. Our BV R light curves and Batten & Lu(1986)'s radial-velocity ones were simultaneously analyzed with contact mode (Mode 3) of Wilson-Devinney's binary model, and the photometric and spectroscopic solutions for BV Dra were solved. In the analysis, we derived the solutions of 1999 light curves with and without spots, respectively. As the results, asymmetry of light curves may be interpreted as produced by the existence of two spots; hot spot on the secondary and cool on the primary. Combining solutions of light curves and radial-velocity ones, absolute dimensions of BV Dra are $M_1=0.40M_{odot}$, $M_2=1.01M_{odot}$, $R_1=0.72R_{odot}$, $R_2=0.40R_{odot}$. In mass-radius diagram, the less massive and hotter primary component of BV Dra is near TAMS and the secondary is near ZAMS, which is very similar to the other W-type W UMa binaries.

  • PDF

A Study on Spatial Statistical Perspective for Analyzing Spatial Phenomena in the Framework of GIS: an Empirical Example using Spatial Scan Statistic for Detecting Spatial Clusters of Breast Cancer Incidents (공간현상 분석을 위한 GIS 기반의 공간통계적 접근방법에 관한 고찰: 공간 군집지역 탐색을 위한 공간검색통계량의 실증적 사례분석)

  • Lee, Gyoung-Ju;Kweon, Ihl
    • Spatial Information Research
    • /
    • v.20 no.1
    • /
    • pp.81-90
    • /
    • 2012
  • When analyzing geographical phenomena, two properties need to be considered. One is the spatial dependence structure and the other is a variation or an uncertainty inhibited in a geographic space. Two problems are encountered due to the properties. Firstly, spatial dependence structure, which is conceptualized as spatial autocorrelation, generates heterogeneous geographic landscape in a spatial process. Secondly, generic statistics, although suitable for dealing with stochastic uncertainty, tacitly ignores location information im plicit in spatial data. GIS is a versatile tool for manipulating locational information, while spatial statistics are suitable for investigating spatial uncertainty. Therefore, integrating spatial statistics to GIS is considered as a plausible strategy for appropriately understanding geographic phenomena of interest. Geographic hot-spot analysis is a key tool for identifying abnormal locations in many domains (e.g., criminology, epidemiology, etc.) and is one of the most prominent applications by utilizing the integration strategy. The article aims at reviewing spatial statistical perspective for analyzing spatial processes in the framework of GIS by carrying out empirical analysis. Illustrated is the analysis procedure of using spatial scan statistic for detecting clusters in the framework of GIS. The empirical analysis targets for identifying spatial clusters of breast cancer incidents in Erie and Niagara counties, New York.

Long-term distribution trend analysis of largemouth bass (Micropterus salmoides), based on National Fish Database, and the ecological risk assessments (전국자연환경조사 자료를 이용한 배스(Micropterus salmoides) 시공간 분포 분석 및 생태위해성 평가)

  • Kim, Jeong Eun;An, Kwang-Guk
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.2
    • /
    • pp.207-217
    • /
    • 2021
  • Using the data from the national survey of fish, we determined the population size and the distribution of Micropterus salmoides, which is a translocated species into the aquatic ecosystem of Korea. . The spatial concentration of this species was determined by performing an optimized hot spot analysis. After determining potential invasiveness and risk assessment, we measured the disturbance of biodiversity in the aquatic ecosystem. The result of distribution analysis indicates that the population of M. salmoides was concentrated in the major basins of Han river, Geum river, Nakdong river, and Yeongsan-Seomjin river, including the Jeju island. In particular, Nakdong river basin showed the highest appearance rate. On the contrary, Yeongsan-Seomjin river basin showed the lowest appearance rate. The Nakdong river and the Nakdong river basin were the areas with the high spatial concentration of M. salmoides. On the other hand, only Han river basin and Geum river basin had the lowest spatial concentration. The fish invasiveness screening kit(FISK) was used to assess M. salmoides, which inhabited a broad region of aquatic ecosystem: the assessment score was 31.0, indicating its 'highly invasive' nature. Our study aims to encourage research that improves the biodiversity and the conservation of M. salmoides in a priority area.

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

Correlation and Spatial Analysis between the number of Confirmed Cases of the COVID-19 and Traffic Volume based on Taxi Movement Data (택시 이동 데이터 기반 COVID-19 확진자 수와 교통량 간의 상관관계 및 공간분석)

  • Jeon, Seung Bae;Kim, Geon;Jeong, Myeong-hun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.6
    • /
    • pp.609-618
    • /
    • 2021
  • The spread and damage of COVID-19 are putting significant pressure on the world, including Korea. Most countries place restrictions on movement and gathering to minimize contact between citizens and these policies have brought new changes to social patterns. This study generated traffic volume data on the scale of a road network using taxi movement data collected in the early stages of the COVID-19 third pandemic to analyze the impact of COVID-19 on movement patterns. After that, correlation analysis was performed with the data of confirmed cases in Daegu Metropolitan City and Local Moran's I was applied to analyze the effect of spatial characteristics. As a result, in terms of the overall road network, the number of confirmed cases showed a negative correlation with taxi driving and at least -0.615. It was confirmed that citizens' movement anxiety was reflected as the number of confirmed cases increased. The commercial and industrial areas in the center of the city confirmed the cold spot with a negative correlation and low-low local Mona's I. However, the road network around medical institutions such as hospitals and spaces with spatial characteristics such as residential complexes was high-high. In the future, this analysis could be used for preventive measures for policymakers due to COVID-19.

Optimal Design of PV Module with Bypass Diode to Reduce Degradation due to Reverse Excess Current

  • Jung, Tae-Hee;Kang, Gi-Hwan;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.5
    • /
    • pp.279-283
    • /
    • 2014
  • In this paper, we present an economical and practical standard to install a bypass diode in a thin-film PV module. This method helps to reduce heat generation and to prevent module degradation due to excess current from reverse bias. The experimental results confirm that for different numbers of solar cells, there is a relation between the excess reverse current and the degradation of solar cells in a-Si:H modules. The optimal number of solar cells that can be connected per bypass diode could be obtained through an analysis of the results to effectively suppress the degradation and to reduce the heat generated by the module. This technique could be expanded for use in high power crystalline Si PV modules.

Ultimate and Fatigue Strength of Ship Hopper Knuckles (선체 호퍼너클 구조의 최종강도 및 피로강도)

  • 김영한;정장영;백점기;김하수;김도현
    • Journal of Welding and Joining
    • /
    • v.18 no.1
    • /
    • pp.77-82
    • /
    • 2000
  • The aim of the present study is to investigate the characteristics of ultimate the fatigue strength of hopper knuckles in merchant vessels carrying bulk cargo or LNG/LPG/ The ultimate strength test is undertaken on the hopper knuckle model, subject to end tip load. A series of fatigue tests are carried out on the hopper knuckle models varying the level of the nominal stresses. The elasto-plastic finite element analysis is performed to examine the distribution of hot spot stresses near weld toe and also the progressive collapse behavior of the test model. S-N curves are developed based on the fatigue test results.

  • PDF

A Performance Analysis of Region-based Overlay Multicast Routing Protocol for Ad Hoc Networks (Ad Hoc 네트워크를 위한 지역기반 오버레이 멀티캐스트 라우팅 프로토콜의 성능 분석)

  • Kim Kap-Dong;Park Jun-Hee;Lee Kwang-Il;Kim Hag-Young;Kim Sang-Ha
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2006.05a
    • /
    • pp.1037-1040
    • /
    • 2006
  • This paper presents an efficient overlay multicast routing protocol (ROMP) and its architecture. ROMP using GPS and region map stands on the basis of scalable 2-tiered multicast architecture and maintains a global overlay multicast tree through reactive fashion. With this approach, the coarse-grain location-awareness for an efficient overlay multicasting and the determination of hot-spot area for efficient data delivery are feasible. The simulation results show that the localized control packets of ROMP prevent the overlay control packets from squandering the physical network resources.

  • PDF

A Study on the Thermal distribution of the 30kVA Pole Transformer Due to the Rated load (30kVA 주상 변압기의 정격부하에 의한 열분포에 관한 연구)

  • Kim, M.K.;Kim, J.T.;Koo, J.Y.;Song, K.D.;Cho, Y.O.;Ha, B.N.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.292-295
    • /
    • 1991
  • The life of the transformers is significantly dependent upon the rate of thermal deterioration in the employed insulating materials. Therefore, the study should be based on hot-spot temperature considerations for the life expectancy and possible overload of transformer. We have measured directly temperature of the winding using thermocouples and these test results are compared with those obtained from computer simulation. In this work, our fundamental investigations are well described for the analysis in the thermal distribution of the oil-immersed transformer with the rating of 30kVA.

  • PDF