• Title/Summary/Keyword: Hot-Cold

Search Result 1,451, Processing Time 0.026 seconds

A Study on the Effects of Side Jets to the Longitudinal Aerodynamics of Subsonic Missile (측방 제트가 아음속 유도탄 종방향 공력특성에 미치는 영향 연구)

  • GO, Beom Yong;HUR, Ki Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.393-404
    • /
    • 2017
  • Side jet effect on the aerodynamic characteristics of a missile was investigated using experimental and computational methods. A couple of side jets were injected toward outward downstream at mid point of missile body. Cold air jet was used in the wind tunnel test, and cold and hot jet were used in the computation. Wind tunnel test was carried out with jet and without jet, and calculation was performed for three cases ; no jet, cold air jet, and hot mixture gas jet. From the comparison of measured and calculated data for all cases, two points could be deduced. Firstly, side jet made static stability to be unstable by increasing body normal force near the side jet exit and by decreasing tail normal force. Secondly, hot mixture gas had more significant effect on the static stability of a missile-type body than cold air jet.

An Experimental Study on the Application in-situ of Curing Method by Planar Surface Heater for Cold Weather Concreting (전기발열시트 표면가열 양생공법의 현장적용 연구)

  • 김형래;조호규;김찬수;지남용
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.19-22
    • /
    • 2003
  • The purpose of this study is to analyze the curing effect of planar surface heater for concreting in cold weather. Some experiments were conducted to evaluate the temperature history of concrete structures cured with heating sheets. Results are as follows ; (1) The temperature of concrete showed continuously rising trend with the heating by planar surface heater under the cold environmental condition of 3~-12$^{\circ}C$. And after about 24 hours the maximum temperature of concrete was reached at 25~3$0^{\circ}C$. (2) The temperature of slab concrete heated by planar surface heater of 130W/$m^2$ was at least $25^{\circ}C$ higher than that of an exterior air, and the curing performance was much more effective than heating by hot wind machine. (3) Through the curing by planar surface heater for 48 hours, the concrete maturity of about 1.5 times to heating by hot wind machine was acquired.

  • PDF

Cold Data Identification using Raw Bit Error Rate in Wear Leveling for NAND Flash Memory

  • Hwang, Sang-Ho;Kwak, Jong Wook;Park, Chang-Hyeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.12
    • /
    • pp.1-8
    • /
    • 2015
  • Wear leveling techniques have been studied to prolong the lifetime of NAND flash memory. Most of studies have used Program/Erase(P/E) cycles as wear index for wear leveling. Unfortunately, P/E cycles could not predict the real lifetime of NAND flash blocks. Therefore, these algorithms have the limited performance from prolonging the lifetime when applied to the SSD. In order to apply the real lifetime, wear leveling algorithms, which use raw Bit Error Rate(rBER) as wear index, have been studied in recent years. In this paper, we propose CrEWL(Cold data identification using raw Bit error rate in Wear Leveling), which uses rBER as wear index to apply to the real lifetime. The proposed wear leveling reduces an overhead of garbage collections by using HBSQ(Hot Block Sequence Queue) which identifies hot data. In order to reduce overhead of wear leveling, CrEWL does not perform wear leveling until rBER of the some blocks reaches a threshold value. We evaluate CrEWL in comparison with the previous studies under the traces having the different Hot/Cold rate, and the experimental results show that our wear leveling technique can reduce the overhead up to 41% and prolong the lifetime up to 72% compared with previous wear leveling techniques.

Design and Implementation of Cold-Flow and Hot-Fire Test Stand of a Cryogenic Propellant Injector Used in LRE (초저온 추진제를 사용하는 액체로켓용 인젝터의 수류/연소시험장치 설계 및 제작)

  • Kim, Do-Hun;Park, Young-Il;Koo, Ja-Ye
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.61-65
    • /
    • 2010
  • To research and develop a liquid rocket engine injector, it needs empirical studies about the hydrodynamic and spray characteristics such as pressure drop, mixing and atomization. In this study, the design and implementation of lab-scale cold-flow/hot fire test stand which can supply cryogenic propellant and be controlled by time-critical LabVIEW cyclogram logic has been done. In order to visualize the spray of a liquid-centered swirl coaxial injector in cryogenic condition, LN2-GN2 cold-flow test has been done, and combustor assembly and thrust bed for LOX-$GCH_4$ hot-fire test have been fabricated.

  • PDF

A Study on Efficient Cut-off Point between Hot and Cold Items for Data Broadcast Scheduling (데이터 방송 스케줄링에서 핫아이템과 콜드아이템의 분리를 위한 효율적인 컷오프 포인트에 관한 연구)

  • Kang, Sang-Hyuk
    • Journal of Broadcast Engineering
    • /
    • v.15 no.6
    • /
    • pp.845-852
    • /
    • 2010
  • Collecting statistics from client requests, the broadcast server partitions data items into hot and cold-item sets with the optimal cut-off point. Hot items are broadcast periodically with periods based on their access probabilities. In a time slot with no hot items scheduled, the server broadcasts a proper cold item considering the waiting time and the number of outstanding requests. We analyze the optimal the cut-off point by calculating average response time as a function of the cut-off point. Simulation results show that our proposed algorithm outperforms existing methods in various circumstances.

Characteristics of Elementary Students따 Conception of Temperature with their Heat Conception (초등학생의 열 개념에 따른 온도 개념의 특성)

  • 권성기;김익진
    • Journal of Korean Elementary Science Education
    • /
    • v.22 no.1
    • /
    • pp.15-28
    • /
    • 2003
  • The purpose of this study was to explore the relationships between the concept of heat and that of temperature for elementary students. Eight multiple choice type questions with explanation of reasons for selection were developed based on previous researches and the analysis of science curriculum for elementary students. The students of 9, 10, 11 years(n=292) were selected from two elementary schools in Taegu City. The responses of students' multiple choice and their explanations were analysed in each items χ² test used for the relationships between types of heat and temperature conceptions Half of elementary student could discriminate the two terms of heat and temperature, majority of them thought that heat is likely to be hot and temperature is the quantity of heat, which is not based on scientific conception. Elementary students thinkings about heat could be classified with material type of heat and molecular kinematics type. Material type of heat were more popular than with molecular kinematics type, although the latter is increased. Majority of students answered correctly in qualitative questions of mixing of hot and cold water, but about only one third of them answers in quantitative questions. Subtraction of cold temperature from hot temperature was the most popular explanation, even though one-quarter of students summed up the two temperature in quantitative situation of mixing hot and cold waters. Those who thought heat as the molecular kinetic responded more correctly in most difficult questions than those who as the material. Therefore, we concluded that the types of heat conceptions affected the concept formation of temperature.

  • PDF

Application of Spatial Autocorrelation for the Spatial Distribution Pattern Analysis of Marine Environment - Case of Gwangyang Bay - (해양환경 공간분포 패턴 분석을 위한 공간자기상관 적용 연구 - 광양만을 사례 지역으로 -)

  • Choi, Hyun-Woo;Kim, Kye-Hyun;Lee, Chul-Yong
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.4
    • /
    • pp.60-74
    • /
    • 2007
  • For quantitative analysis of spatio-temporal distribution pattern on marine environment, spatial autocorrelation statistics on the both global and local aspects was applied to the observed data obtained from Gwangyang Bay in South Sea of Korea. Global indexes such as Moran's I and General G were used for understanding environmental distribution pattern in the whole study area. LISAs (local indicators of spatial association) such as Moran's I ($I_i$) and $G_i{^*}$ were considered to find similarity between a target feature and its neighborhood features and to detect hot spot and/or cold spot. Additionally, the significance test on clustered patterns by Z-scores was carried out. Statistical results showed variations of spatial patterns quantitatively in the whole year. Then all of general water quality, nutrients, chlorophyll-a and phytoplankton had strong clustered pattern in summer. When global indexes showed strong clustered pattern, the front region with a negative $I_i$ which means a strong spatial variation was observed. Also, when global indexes showed random pattern, hot spot and/or cold spot were/was found in the small local region with a local index $G_i{^*}$. Therefore, global indexes were useful for observing the strength and time series variations of clustered patterns in the whole study area, and local indexes were useful for tracing the location of hot spot and/or cold spot. Quantification of both spatial distribution pattern and clustering characteristics may play an important role to understand marine environment in depth and to find the reasons for spatial pattern.

  • PDF

Pretreatments of Softwood Sawdust for Mycelial Growth of Lentinus edodes

  • Kim, Tae-Hong;Lim, Bu-Kug;Chang, Jun-Pok;Yoon, Kab-Hee;Lee, Jong-Yoon;Yang, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.109-115
    • /
    • 2002
  • Mycelial growth of L. edodes by pretreatments of softwood was studied on a sawdust medium. The sawdust used was from the following softwood species : Larix leptolepis, Pinus densiflora and Pinus koraiensis. The pretreatment consisted of cold-water (48 h), hot-water (3 h) and steam extractions (3 h) at a ratio of 500 g : 3,000 mL (sawdust : distilled water). The sawdust medium was a mixture of 76% sawdust, 20% rice bran, 3% glucose, 0.4% potassium nitrate and 0.6% calcium carbonate. Following sawdust pretreatments proved most suitable : L. leptolepis (steam extraction), P. densiflora (hot-water extraction) and P. koraiensis (hot-water extraction). Mycelial growth on P. koraiensis sawdust increased in proportion to an increase in hot-water extraction time. Mycelial growth was optimum on the sawdust extracted for 12 hours, hot-water extraction beyond this period proved unsuitable. With the exception of P. densiflora at 100 ㎍/mL, antifungal activity occurred in every sample. Maximum inhibition of mycelial growth was obtained from following concentration of hot-water extractives : P. densiflora (104 ㎍/mL) and P. koraiensis (104 ㎍/mL). This study has provided useful preliminary information for the cultivation of L. edodes.

Important Items Extracted through the Questionnaire of Cold and Heat Pattern Identification by the Experts' Agreement (전문가의 일치도를 통해 알아본 중요 한증, 열증 지표)

  • Bae, Kwang Ho;Park, Ki Hyun;Lee, Young Seop;Jang, Eun Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.30 no.6
    • /
    • pp.466-473
    • /
    • 2016
  • This study intended to find out the most substantial items in cold and heat pattern identification(CHPI) questionnaire based on usual symptoms through CHPI diagnosis and evaluation by experts. 120 participants, faculties of OO university, filled out CHPI questionnaire based on usual symptoms by the way of self-reporting. Then 2 Korean Medicine doctors independently diagnosed them whether they belonged to cold pattern identification(PI) or heat PI, and scored the result of it. Pearson correlation of 2 experts was 0.649 in cold PI and 0.605 in heat PI. Agreement was 75.8%(Kappa value 0.516) in cold PI and 74.2%(Kappa value 0.465) in heat PI. Pearson correlation of 2 experts was 0.649 in cold PI and 0.605 in heat PI. Agreement between two experts was 75.8%(Kappa value 0.516) in cold PI and 74.2%(Kappa value 0.465) in heat PI. Items of high correlation with experts' evaluation followed next: "do not usually like the cold", "usually like the warm", "usually feel cold" in cold PI and "do not usually like the hot", "usually feel hot", "usually feel burning sensation in the body" in heat PI. We could infer from that facts that experts give weight on 'subjective feeling of cold or heat in participants body' and 'preference on sensation of cold and heat'. We also expect this study to be an epidemiological foundation to disclose correlation between usual CHPI and diseases.

An Experimental Study on the Mass and Energy Release for a Hot Leg Break LBLOCA During Post Blowdown

  • S.J. Hong;Kim, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.108-127
    • /
    • 2000
  • Hot leg break LBLOCA(Large Break LOCA) had a potential to be a containment maximum pressure accident in YGN3&4, which was induced from excessive conservatism in the CE analysis methodology of mass and energy release. This study conducted mass and energy release experiment for the hot leg break LBLOCA during post blowdown with an integral test facility, SNUF(Seoul National University Facility). This facility simulated YGN 3&4 with volume ratio of 1/1140 based on Ishii's three level scaling. Experiment showed that SI(Safety Injection) water refilled cold leg first and core later. SI water was vaporized in the core, which resulted in the repressurization of reactor. This increase of pressure drove the water in cold leg to flow up half height of U tubes. However, since the water was drained back soon, the release through the SG side broken section by evaporation was negligibly small. This study also provided experimental assessment of RELAP5 results by KAERI for the release through the SG side broken section.

  • PDF