• 제목/요약/키워드: Hot Smoke Test

검색결과 14건 처리시간 0.02초

Hot smoke test 를 위한 화염 제어 방법 (Flame control method for hot smoke test)

  • 김진국
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1996년도 학술발표회
    • /
    • pp.30-33
    • /
    • 1996
  • This paper presents the technical basis for hot smoke test intended to investigate the effectiveness of smoke ventilation system in both high-rise building and those containing atria and/or galleria. Smoke is particularly serious hazard in these building in which considerable time is required for complete evacuation. It is widely recognised that the effectiveness of large smoke ventilation system can be difficult to confirm by a critical analysis of the system design calculation. Thus a hot smoke test is recently introduced through the experiences of many attempts. Diffusion flames used for hot smoke test have a higher flame length, so that those can not be applied to small compartment. Therefore the objective of this paper is introducing the method of flame control which can be applied to any size of compartment

  • PDF

지하철 본선터널 제연성능 실물 실험 (Full-Scale Test of Smoke-Control Performance of a Subway Tunnel)

  • 박원희;이덕희;정우성
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.94-102
    • /
    • 2011
  • 지하철 본선터널에서 고온 연기시험을 수행하였다. 고온의 화재연기를 모사하기 위하여 약 1.0MW의 알콜트레이 및 연기발생장치를 이용하였다. 화재발생후 9분 후에 터널내에 설치된 팬이 순차적으로 작동하여 화재 연기가 제어되는지를 확인하였다. 터널내의 주요 위치에서의 풍속, 풍향, 온도 및 연기농도 등을 측정하여 이를 화재안전 관점에서 분석하였다. 화재 인근의 천장부분의 풍속 측정값으로 연기의 속도를 구하였으며, 위치별 제연기류가 형성되는 시간이 상이한 것을 확인하였다. 본 연구에서 계측된 풍속분포를 이용하여 지하철 본선터널 제연설비 성능 평가를 위한 수치해석의 경계값 및 비교결과로 활용될 것이다.

Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가 (Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test)

  • 정석환
    • 한국방재안전학회논문집
    • /
    • 제12권2호
    • /
    • pp.47-56
    • /
    • 2019
  • 주차장 화재 시 다량의 연기 발생으로 소방대원이 화점에 진입하기 곤란한 문제점을 극복하고자 최근 주차장 환기 목적으로 설치된 급 배기팬과 유인팬(Jet fan)을 이용하여 연기를 배출하는 방법을 이용하고 있다. 본 연구에서는 급배기팬만 동작하는 조건과 유인팬이 함께 동작하는 2가지 조건에서 연기층의 유동변화를 CCTV를 이용하여 관찰하였으며, 또한 hot smoke test가 주차장 환기 성능평가 방법으로서의 적정성을 평가하기 위해 플럼 주위의 온도를 Alpert eq.과 비교 분석하였다. 그 결과 jet fan을 동시에 동작시키는 경우 연기층이 교란될 수 있음을 확인할 수 있었으며, 그로인하여 초기 피난 장애 우려가 있을 것을 것으로 분석되었다. 다만, jet fan이 추가로 작동됨에 따라 배기성능은 향상되는 것을 관찰용 CCTV로 확인할 수 있었으며, 이는 진압전술을 펴는데 도움이 될 것으로 판단된다. 플럼 주변의 온도를 측정하여 Alpert eq과 비교한 결과 Plume 중심축에서 약 $2^{\circ}C$ 낮고 연기가 배출되는 방향으로 8 m에서는 $9.0^{\circ}C$ 높은 것으로 분석되었다. Plume 주변의 온도 측정 결과는 AS 4391-1999의 예상 최대 온도보다 낮았고 실험으로 인한 예상 온도 위험을 초과하지 않았다. 이 결과와 같이 고온 연기 시험의 진행으로 인한 온도 위험성이 예측 가능하기 때문에 관련 기준이 없는 주차장의 연기 제어 성능 평가를 위한 일반적인 평가 방법 중 하나로 활용 가능할 것이다.

여지반사식과 광투과식 매연측정기의 매연도 상관계수에 관한 연구 (A Study of the Opacity Correlation Factor between the Filtration Type and Light Extinction Type Diesel Smoke Meters)

  • 김영주;박경석
    • 한국자동차공학회논문집
    • /
    • 제15권5호
    • /
    • pp.146-152
    • /
    • 2007
  • Recently, The air pollution problems become hot issues as the production of the diesel automotive increases. The ministry of environment has enforced a precise inspection law to decrease the vehicle emission. In this circumstances, the smoke measurement is somewhat complicated by the use of the different type smoke meters. Although the paper filtration type opacimeter has been used for measuring smoke widely but currently the light extinction type is being used for precise inspection law. These two type opacimeters are different in their measuring principles on each other. So, for the time being the regulation standards can be confused by these two type opacimeters. In this article, The correlation factor between these two type opacimeters is studied by using engine dynamometer and vehicle test. The result of the dynamometer test shows the light extinction type is more sensitive than the filtration type by 1.47 times. But the relation factor by the vehicle test achieved 1.37 value, which is lower than that of the dynamometer test. In the future study the more precise research is needed to estimate the relation factor on vehicle test.

제연설비 성능시험방법의 표준화 (Standardization of the Performance Test Procedure for Smoke Control System)

  • 곽지현
    • 한국화재소방학회논문지
    • /
    • 제20권3호
    • /
    • pp.21-28
    • /
    • 2006
  • 화재 시 발생하는 고온의 유독가스는 가장 주요한 사망원인이며 공기와는 다른 유체역학적 특성을 가지므로 화재실의 형상과 특징에 맞는 제연방식이 필요하고 제연설비 각 구성품은 이에 따른 일정한 성능을 요구하게 되는데, 이를 위해서는 성능시험방법과 평가기준이 정립되어 있어야 한다. 이와 관련된 국내 기준은 서류에 의한 예비검사나 부위검사 등으로 되어 있어 성능위주의 평가방법 및 기준이 미비한 실정으로 국제규격과 비교해볼 때 여러 가지 문제점을 가지고 있다. 따라서 제연설비 주요 구성품인 제연경계벽, 배연구, 송풍기, 풍도, 방연댐퍼에 대해 국내외 기준을 비교 분석하고 문제점을 도출하여 각 구성품의 성능시험방법 표준화를 위한 방안을 제시하였다.

국내·외 누설률에 관한 기준 분석을 통한 국내 연기제어 기준 개선에 관한 연구 (A Study on the Improvement of Domestic Smoke Control Standards through Analysis the Standards about Air Leakage Rate of Domestic and Abroad)

  • 김혜원;한지우;이병흔;진승현;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.61-62
    • /
    • 2018
  • On this Study, it conducts the Standards investigation about air leakage of Buildings for performance improvement of Smoke control in Fire. In domestic standards, it is incomplete the Criteria standards of air leakage. Therefore it is considered that won't limit the smoke spread due to stack effect. But in the case of the United States, it conducts the Hot smoke air-Leakage test and it consider that can prevent the Smoke Spread in Compartment.

  • PDF

수평 원통 관에서 선회를 동반한 유동각에 대한 실험적 연구 (An Experimental Study on Flow Angle with Swirl in a Horizontal Circular Tube)

  • 장태현
    • 한국기계가공학회지
    • /
    • 제2권4호
    • /
    • pp.82-87
    • /
    • 2003
  • Flow angle with Swirl in a horizontal circular tube and a cylindrical annuli were experimentally studied for its visualization. This present investigation deals with flow angle, flow visualization studies and vortex core by using oil smoke and a hot wire anemometer for Re = 40,000 and 50000 at X/D = 41, 59 and 71 in a horizontal circular tube. In the swirl air flow, a vortex core was formed at high swirl intensity along the test tube. The flow angle and the vortex core depended on the swirl intensity along the test tube. The results of flow angles with swirl measured by flow visualization and hot wire reasonably agree with those of Sparrow One of the primary objectives of this research was to measure the flow angle with swirl in a cylindrical annuli along the test tube for different Reynolds numbers. The Reynolds number for these measurements ranged from 60,000 to 100,000 with L/D = a to 4.

  • PDF

대형디젤기관의 EGR에 의한 배기가스변화에 관한 실험적 연구 (An Experimental Study on Exhaust Gas Change of a Heavy-Duty Diesel Engine by EGR)

  • 오용석;문병철;한영출
    • 한국자동차공학회논문집
    • /
    • 제10권6호
    • /
    • pp.59-64
    • /
    • 2002
  • The effects of EGR on emissions were investigated by using a six-cylinder, 8 litre, turbo-charged, heavy-duty diesel engine with a low pressure route EGR system. The experiments were performed at various engine loads while the EGR rates were set from 0% to 30%. Hot and cooled EGR are achieved without cooling and with cooling respectively. To verify the possibility of EGR technology for the applications, test were performed with steady state test cycle. It was found that the exhaust emissions with the EGR system resulted in a very large reduction in oxides of nitrogen at the expense of higher smoke and PM emissions. Increasing the EGR rate leads to deteriorating specific fuel consumption and power at lower speed and higher load. Also, the reduction rates of NOx emissions for hot and cooled EGR are similar.

An Experimental Investigation of Swirl Angle in a Horizontal Round Tube by Flow Visualization Method

  • Tae-Hyun Chang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권7호
    • /
    • pp.879-888
    • /
    • 2003
  • Swirling air flow in a horizontal round tube was experimentally studied for its visualization. The present investigation deals with swirl angle, flow visualization studies and accompanying vortex core behavior by using oil smoke and a hot wire anemometer for Re = 40,000 and 50000 at X/D = 41, 59 and 71. In the swirl air flow, a vortex core was formed at high swirl intensity along the test tube. The swirl angle and the vortex core depended on the swirl intensity along the test tube. The results of swirl angles measured by flow visualization and hot wire reasonably agree with those of previous studies.

방화Damper의 성능기준 고찰 (Investigation of Performent Standards for the Fire Damper)

  • 조중달
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.10-17
    • /
    • 1992
  • Dampers which being installad in air duct are Valume damper, fire damper, leakage rated damper, but among them fire damper and leakage rated damper are used for preventing the spread of flame, hot gas and smoke through the duct. this report is aimed to intorduce the test example of the multiple fire damper which was conducted F.I.L.K, simuetaneously to investigate the performent standards and Structure of the fire damper which settled in several countries.

  • PDF