• 제목/요약/키워드: Horizontal gap

검색결과 225건 처리시간 0.026초

수직배치 구대평판 공기 갭에서 연소화염 존재시의 절연파괴 특성 (Breakdown Characteristics of a Vertical Sphere-Plane Air Gap in the Presence of Combustion Flame)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, breakdown characteristics of a vertical sphere-plane air gap in the presence of combustion flame were examined under the application of a.c. and d.c. high-voltages in order to investigate the effect of flame on the dielectric strength of air. Propane gas is used as the fuel of the flame, and the temperature distribution of air around the flame is measured. The polarity effects for the d.c. voltages and breakdown voltages of air when applied both of a.c. and d.c. voltages were examined in the case of the variation of the gap length and the horizontal distance between the flame and the high-voltage sphere electrode. The influence of relative air density, electrification and shape changes of the flame as factors that affect the breakdown voltages were discussed.

수평타원 환상공간에서의 자연대류에 관한 실험적 연구 (An experimental study on natural convection in the annuli between two horizontal elliptic cylinders)

  • 이재순;서정일;이택식
    • 대한기계학회논문집
    • /
    • 제12권1호
    • /
    • pp.28-35
    • /
    • 1988
  • 본 연구는 이중벽용기에서 볼 수 있는 환상공간에 관한 자연대류 연구로서 용기속에 들어있는 유체의 열차폐를 위한 최적의 가스두께를 측정하기 위하여 필요한 지식을 얻기위한 열전달 연구이다.

수평으로 매설된 도선의 접지임피던스의 주파수의존성을 계산하는 기법 (A Method of Computing the Frequency-Dependent Ground Impedance of Horizontally-buried Wires)

  • 조성철;이복희
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.745-752
    • /
    • 2016
  • The parameters of Debye's equation were applied to analyze the frequency-dependent ground impedance of horizontally-buried wires. We present a new method, based on Debye's equation, of analyzing the effect of polarization on frequency-dependent ground impedance. The frequency-dependent ground impedances of a horizontally-buried wire are directly measured and calculated by applying sinusoidal current in the frequency range of 100 Hz to 10 MHz. Also, the results obtained in this work were compared with the data calculated from empirical equations and commercial programs. A new methodology using the delta-gap source model is proposed in order to calculate frequency-dependent ground impedance when the ground current is injected at the middle-point of the horizontal ground electrode. The high frequency ground impedance of horizontal electrodes longer than 30 m is larger or equal to its low frequency ground resistance. Consequently, the frequency-dependent ground impedance simulated with the proposed method is in agreement with the experimental data, and the validity of the computational simulation approach is confirmed.

미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구 (An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights)

  • 이상용;이한주
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.

Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

  • Colak, Ozlem;Kankaya, Yuksel;Sungur, Nezih;Ozer, Kadri;Gursoy, Koray;Serbetci, Kemal;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • 제46권3호
    • /
    • pp.228-234
    • /
    • 2019
  • Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was $44.6{\pm}4.3N$ in group 1, $35.7{\pm}5.2N$ in group 2, and $56.7{\pm}17.3N$ in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.

단순교합기에 의한 하악운동의 오차에 대한 실험적 연구 (An Experimental study on the gap of movement by the hinge articulator)

  • 문희경
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

슬랙스 형태 적합성 평가의 정량적 평가 기준 설정 (Establishing Quantitative Evaluation Standards for the Shape Fitness test of Slacks)

  • 김선영
    • 한국의류산업학회지
    • /
    • 제18권5호
    • /
    • pp.695-707
    • /
    • 2016
  • This study presents quantitative evaluation standards for the shape fitness test, conducted in the process of the slacks fit test. This study aims to quantify appearance sensory test of slacks for the objectification of qualitative evaluation methods in existing shape fitness tests. The subjects were women of standard body type between the ages of 18 and 24. Slacks differing in their ease in waist girth, hip girth, crotch length and knee length were designed to test their shape fitness. The gap volume distribution between the body and slack, angle of the baseline by body part, and ratio of total thickness from the sideline using 3D human body scan data (which reflect the results of the appearance sensory test) were presented as quantitative evaluation standards. There were less wrinkles in the wrinkle/overstretch and ease categories of the appearance sensory test; in addition, ease was adequate and small enough to comfortably perform basic human activities in the standing upright posture. The gap volume distribution analysis between body and slacks showed that curves increased in the slacks surface along with an increase of ease in slacks and suggested that wrinkles also increased. In the baseline's horizontal categories in terms of a $0^{\circ}$ horizontal angle, the range of angles were evaluated as adequate by the clothing expert group. The total thickness ratio of 0.5:0.5 divides into the sideline from the baseline.

금붕어의 동작 감지에 미치는 갭 정션의 역할: 시각운동 반응 측정 (The Role of Gap Junction in the Goldfish's Motion Detection Measured with Optometer Response)

  • 이영섭;윤영현;정창섭
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.252-259
    • /
    • 2006
  • 갭 정션(gap junction)은 다양한 세포에 분포되어 있으며 분자 수준의 작은 물질들이 자유롭게 교환되는 전기적 시냅스다. 망막에서, 갭 정션의 차단이 동물의 동작 감지(motion detection)에 실제적으로 어떤 영향을 주는지에 대해서는 거의 조사되지 않았다. 본 연구에서는, 망막 세포간의 전기적 시냅스를 조절하는 약물이 금붕어의 동작 감지에 어떠한 영향을 주는지를 조사하기 위해 시각운동 반응(optometer response, OMR)이 사용되었다. 갭 정션 차단제인 carbenoxolone, 8-bromo cyclic AMP, sodium nitroprusside (SNP), 8-bromo-cyclic GMP 등의 초자체 내 주사는 광- 및 암-상태에서 모두 OMR을 감소시켰다. 광-상태에서 dopamine, SKF-38393 및 eticlopride의 주사는 OMR을 감소시킨 반면 SCH-23390의 주사는 OMR을 증가시켰다. 암-상태에서는 결과가 반대로 나타났다: 즉 dopamine, SKF-38393 및 eticlopride의 주사는 OMR을 증가시킨 반면 SCH-23390의 주사는 OMR을 감소시켰다. 이러한 결과는 망막 세포들 사이의 갭 정션이 금붕어의 동작 감지에 중요한 역할을 담당하고 있음을 시사한다.

  • PDF

수평 환형 공간에서의 진동하는 열대류 (OSCILLATORY THERMAL CONVECTION IN A HORIZONTAL ANNULUS)

  • 유주식
    • 한국전산유체공학회지
    • /
    • 제11권2호
    • /
    • pp.49-55
    • /
    • 2006
  • This study investigates the oscillatory thermal convection of a fluid with Pr=0.02 in a wide-gap horizontal annulus with constant heat flux inner wall. When Pr=0.02, dual steady-state flows are not found. After the first Hopf bifurcation from a steady to a time-periodic flow, five successive period-doubling bifurcations are recorded before chaos. The power spectrum shows the $period-2^4\;and\;2^5$ flows clearly, and a window of period $3{\times}2^3$ flow is found in the chaotic regime. The approximate value of the Feigenbaum number for the last three period-doubling bifurcations is 4.76. The transition route to chaos of the present simulations is consistent with the period-doubling route of Feigenbaum.

동시 회전하는 수평 실린더 내 환상공간에서의 혼합대류 (Mixed-Convection in an Annulus Between Co-Rotating Horizontal Cylinders)

  • 이관수;김양현;임광옥
    • 대한기계학회논문집B
    • /
    • 제26권4호
    • /
    • pp.622-628
    • /
    • 2002
  • Numerical analysis has been carried out for two-dimensional steady and unsteady mixed convection in the annulus between co-rotating horizontal cylinders with a heated inner cylinder. The ratio of annulus gap($\sigma$) is taken from 1 to 10 and the order of mixed-convection parameter B(=Gr/(1+Re)$^2$) varies from 10$^4$to $10^0$. The flow patterns over this parameter range are steady multicellular, oscillatory multicellular or steady unicellular. The addition of co-rotating of both cylinders stabilizes the flow in the annulus and weakens the unsteadiness. Even in the large values of rotating parameter such as of $10^0$/($\sigma$=2) and 10$^2$($\sigma$=10), the flow pattern becomes asymptotic to the steady unicellular flow, like as in the rigid-body rotating flow.