• Title/Summary/Keyword: Horizontal cooperation

Search Result 188, Processing Time 0.02 seconds

Output Characteristics of Small Wind Power Generator Applying Multi-Layered Blade (다층형 블레이드를 적용한 소형 풍력발전기의 출력특성)

  • Lee, Min-Gu;Park, Wal-Seo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.663-667
    • /
    • 2017
  • Fuel depletion and environmental problems due to the use of fossil fuels have been worsening of late, and the development of alternative energy sources is urgently required to address these problems. Among the alternative energy sources, wind energy is attracting much attention as a clean energy source, because it can be used unlimitedly without any pollutant emissions. In wind power generation, wind energy is converted to kinetic energy through rotor blades and this kinetic energy is converted to electric energy through generators. The design and manufacturing of the blades, which are the major parts of wind power generators, are very important, but South Korea still lacks the requisite basic data and key technologies and, therefore, has to import the blades from overseas. In this study, multi-layered blades capable of generating power at low wind speeds were applied to a small wind power generator and the output characteristics of the generator according to the wind speed and the number of blades were analyzed. As a result, at the maximum wind speed of 8m/s, the application of three blades achieved up to 33% and 18% higher generator output voltage, up to 33% and 15% higher generator output current, and up to 23% and 13% higher generator RPM than the application of one or two blades, respectively. In this study, the application of multi-layered blades to a small wind power generator was shown to improve the output characteristics of the generator and make the collection of electric energy possible even at low wind speeds.

Development of the auto leveling mechanism for side-by-side refrigerator doors (양문형 냉장고 도어의 자동 단차 맞춤 메커니즘 개발)

  • Weng, Lei;Yun, Jae-Deuk;Jung, Yoong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.7
    • /
    • pp.3165-3174
    • /
    • 2012
  • Recently the increasingly common large refrigerator is the side by side(SBS) refrigerator whose freezing chamber and refrigerating chamber are set side by side. But one of the biggest dissatisfaction of customers about SBS refrigerator is that the two doors don't meet the same height when they are closed. It is called door height difference(DHD). The main cause of DHD is the unevenness of floor on which a refrigerator is placed or the cabinet deformation caused by long time use. When the DHD is confirmed, the customer or maintenance personnel use wrench to adjust the support screw to make the refrigerator to reach the horizontal position. But for big refrigerator, it is not only difficult for women and old people who don't have enough force to adjust it, but also inappropriate to require customers to do this job. In order to resolve this problem, this research proposes a new mechanism which can detect the DHD and adjust two doors to the same height automatically. The adjustment would be completed during opening and closing the doors, avoid needing hard operation with wrench by hand.

FE Analysis of the Composite Action in the Composite Beam subjected to the Hogging Moment (부모멘트를 받는 합성보의 전단합성 거동에 대한 유한요소해석)

  • Shin, Hyun-Seop
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.4048-4057
    • /
    • 2013
  • In the composite beam subjected to the hogging moment it is very difficult to evaluate the influence of the reduction of slab stiffness due to cracks and their development on the horizontal shear behavior of shear connection. In this study, a 3D FE model is developed by which one can analyze the composite action in the composite beam subjected to the hogging moment. In this FE model, each structural member and shear connection are modeled as similar as possible to details of the composite beam. Bending behaviour, and composite action which could not be analyzed using the existing 1D or 2D FE model are investigated by the 3D model. Analysis results show that the reinforcement ratio and crack behaviour of the slab are main factors which exert a strong influence on the composite action. According to the analysis results about load-slip behavior, initial crack of slab and yielding of rebars have a influence on the slip stiffness of shear connection. The existing experimental results, that the design of partial interaction can be more efficient in designing of shear connection of the composite beams, are indirectly verified by the FE analysis.

Study of spatial temperature distribution during combustion process in a high temperature and pressure constant volume chamber (고온 고압 정적 연소실에서 연소과정에 따른 온도 분포 측정)

  • Kim, Ki-hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.345-350
    • /
    • 2017
  • Downsizing is widely applied to diesel engines in order to improve fuel efficiency and reduce exhaust emissions. Engine sizes are becoming smaller but pressure and temperature inside combustion chambers are increasing. Therefore, research for fuel spray under high pressure and temperature conditions is important. A constant volume chamber which simulates high temperature and pressure likely to be found in diesel engines was developed in this study. Pressure and temperature were increased abruptly because of ignition of the pre-mixture in the constant volume chamber. Then pressure and temperature were gradually decreased due to the heat loss through the chamber wall. Fuel spray occurred when temperature and pressure were reached at the target condition. In this experiment, the temperature condition should be exactly defined to understand the relation between fuel evaporation and ambient temperature. A fast response thermocouple was developed and used to measure the temporal and spatial temperature distribution during the combustion process inside the combustion chamber. In the results, the core temperature was slightly higher than the bulk temperature calculated by the gas equation. Ed-note: do you want to say 'ideal gas equation'? This was attributed to the heat transfer loss through the chamber wall. The vertical temperature deviation was higher than the horizontal temperature deviation by 5% which resulted from the buoyancy effect.

Analysis on Improving Power of Thermal Radiation Shield in Low Pressure Chamber of AMTEC (AMTEC내 저압용기에서의 열복사차단막 형상에 따른 발전량 향상 해석)

  • Chung, Won-Sik;Chi, Ri-Guang;Lee, Wook-Hyun;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.54-62
    • /
    • 2016
  • The most efficient system for converting heat to electricity, AMTEC (Alkali Metal Thermal-to-Electric Convertor), is a device that directly converts heat energy to electricity using an alkali metal (sodium) as the working fluid. The AMTEC consists of a low pressure chamber, high pressure chamber, BASE (Beta-Alumina Solid Electrolyte), and artery wick. The main heat loss of the AMTEC system occurs in the low pressure chamber. A high power generation rate is thought to be obtainable by using a high temperature in the BASE. Therefore, to reduce the radiation heat loss, 6 types of radiation shields were examined to reduce the radiative heat loss in the low pressure chamber. The power generation rate of the AMTEC varied depending on the shape of the radiation shield. CFD (Computational Fluid Dynamics) analyses were carried out to optimize the shape of the radiation shield. As a result, the optimum radiation shield was found to consist of a curvature formed at the vertical point, in which case the dimensionless temperature (condenser temperature/BASE temperature) is approximately 0.665 and the maximum power generated is calculated to be 17.69W. Increasing the distance beween the BASE and condenser leads to an increase in the power generated, and the power generated with the longest distance was 17.58 W. The shields with multiple holes and multiple horizontal layers showed power reduction rates of 0.91 W and 2.06 W, respectively.

Analysis of Performance Tests and Friction Characteristics of a Friction Type Isolator Considering Train Load Conditions (열차 하중조건을 고려한 마찰형 방진장치 성능시험 및 마찰특성 분석)

  • Koh, Yong-Sung;Lee, Chan-Young;Ji, Yong-Soo;Kim, Jae-Wang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.694-702
    • /
    • 2017
  • In the case of an elevated railway station, structure borne noise and vibration due to structural limitations allow the load and vibration from railway vehicles to be directly transmitted to the station structure, resulting in an increase in the number of civil complaints from customers and staff of the station. The floating slab track system, which is well known as one of the solutions for reducing the noise and vibration from elevated railway stations, usually contains rubber mounts or rubber pads under the railway slab which act as a damper. These types of device have the disadvantage that is difficult to predetermine the exact stiffness and damping ratio under the nonlinear loads resulting from train services. In this study, an isolator with a friction type of wedge is introduced, which can be applied to floating slab track systems and to be designed with precisely the required stiffness. Furthermore, a comparative analysis of the stiffness between the designed and experimental values is carried out, while the damping ratio, which is closely related to the friction wedge blocks, is deduced according to the train load condition. The performance tests of the isolator were conducted in accordance with the DIN 45673-7 standard which includes both static and dynamic load tests. The load conditions for the performance tests are designed to conform to the DIN standard related to the weight of the train and rail track, in order to perform vertical and horizontal load tests, so as to ensure the secure structural safety of the railway. Also, by checking the change aspect of the friction coefficients of the friction elements according to the loading rate, the vibration reduction performance of the friction type isolator with variable loading rate conditions is examined.

A Study on the Analysis of Gaze Characteristic of The Villa Savoye - Based on the Difference between Architecture Major Group and Non-Architecture Major Group (빌라 사보아의 건축입면 주시특성 연구 - 건축 전공자와 비전공자의 차이를 중심으로)

  • Cho, Hyeong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.724-731
    • /
    • 2016
  • The purpose of this study was to determine what rules or patterns exist when people gaze at a villa savoye, which is probably Le Corbusier's best known building, using eye-movement tracking techniques. Villa savoye was designed, addressing his emblematic "Five Points", such as pilotis, functional roofs, free floor plans, long horizontal windows, and freely-designed facades. This study examined how the villa savoye's facade image is formed in an objective manner. This study selected a total of 56 test subjects, and showed them an image of a villa savoye. Using eye-movement tracking tools, this study recorded where they mostly gazed at when seeing the building. In addition, an experiment was carried out to test the different points of view, relating to visual attention, between the two groups with different levels of knowledge in architecture. To analyze the data, the Gaze Frequency was used as the key indicator. The results showed that the subjects have a higher degree of attention to either the door or window in general than in former studies. The architecture major group showed that they gazed the experiment image more evenly.

Dynamic Characteristics of Truss-Type Lift Gate According to Installation Direction (트러스형 리프트 게이트의 설치방향에 따른 진동 특성)

  • Lee, Seong-Haeng;Kong, Bo-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.120-127
    • /
    • 2016
  • This study examined the dynamic characteristics of the gate to identify the optimal gate installation direction according to the installation direction. A 1:31 scale model was constructed for a 47.5m prototype gate using acrylic. The scaled weights were tuned by adding lead weights. The first step was to measure the natural frequencies of the model gates, and compare them with finite-element analysis of the prototypes as a calibration. The scaled model was tested in a 1.6 m wide concrete flume for two orientations to determine the effects of the gate orientation on structural vibrations. Vertical vibrations were measured under a range of operational conditions, including a range of bottom opening heights and different upstream and downstream water levels. For large bottom opening heights in the normal direction, relatively large vibrations were induced by vortices shed at the plate bottom that would strike the horizontal truss member. This phenomenon was avoided in the reverse direction. For small bottom opening heights in the normal direction, these vibrations were caused by a suction force that developed at the gate bottom. The gate model in the reverse direction was preferred because of its low overall vibrational response under general gate opening and flow level combinations.

Socioeconomic development, gender equity and birthrate's determinant: focused on the family axis' transformation model (사회경제적 발전, 양성평등 그리고 출산율의 결정요인 -가족 중심축의 수평화 2단계 모형을 중심으로-)

  • Lee, Je-Sang;Song, Yoo-Mee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.256-270
    • /
    • 2016
  • This purpose of this study is to present a new theoretical framework on birthrate recovery in advanced countries in the 21st century. As a result of socioeconomic development and individualism diffusion, the central axis of the family has transformed from the vertical axis of the father-son relation, to the horizontal axis of the husband-wife relation. This process is divided into 2 stages. In the industrialization stage, a nation or a society achieves equality of the individual in family formation, including marriage or divorce. In the post-industrialization stage, it accomplishes the couple equality in family maintenance, including child rearing and household labor. This paper grouped 33 OECD member countries as post- industrialization countries and 103 countries as industrialization countries. This study utilizes 6 variables affecting marriage and childbearing based on previous research. Research results find that during the industrialization stage, the birthrate falls as the education level of women is higher. In the post-industrialization stage, the birthrate rises as gender equality level is higher.

An Analysis of Scour Effect on Hydraulic Energy Dissipater Installation at Weir Downstream (보 하류부 감세공 설치에 대한 세굴 변화 분석)

  • Kang, Joon-Gu;Lee, Chang-Hun;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.453-458
    • /
    • 2016
  • While the design of weirs requires a scour-considered strategy, research on the analysis of the effectiveness of hydraulic energy dissipaters and design criteria are scarce due to the limited experimental facilities and restraint in the experiment conduction period. The study analyzed the scour dissipation effect of multidirectional dissipaters to improve the scour problems of a weir downstream and suggests design criteria to minimize scour. A hydraulic model experiment was conducted for Nakdong River Hapcheon-Changnyeong Weir and a model in 1/25 of horizontal accumulation and 1/25 of vertical accumulation was produced. The experimental equipment was classified into channels and a flow rate supply and an underwater pump were installed to enable flow at a maximum of 2.0 m3/s. The experimental inflow was 1.3 m3/s, the upstream water level was 0.36 m, downstream water level was 0.24 m, and a cylinder wooden baffle, a dissipater, with a diameter of 0.05 m was made. A 3D scanner was also used for an accurate scour depth comparison for a length change of the baffle before and after installing the baffle. When the baffle was arranged in the shape of a V, the depth of scour decreased by 36% while the scour length decreased by 49% due to flow reduction compared to that before installing the baffle.