• Title/Summary/Keyword: Holter monitoring system

Search Result 7, Processing Time 0.019 seconds

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.2
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

Design of a Holter Monitoring System with Flash Memory Card (플레쉬 메모리 카드를 이용한 홀터 심전계의 설계)

  • 송근국;이경중
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.251-260
    • /
    • 1998
  • The Holter monitoring system is a widely used noninvasive diagnostic tool for ambulatory patient who may be at risk from latent life-threatening cardiac abnormalities. In this paper, we design a high performance intelligent holter monitoring system which is characterized by the small-sized and the low-power consumption. The system hardware consists of one-chip microcontroller(68HC11E9), ECG preprocessing circuit, and flash memory card. ECG preprocessing circuit is made of ECG preamplifier with gain of 250, 500 and 1000, the bandpass filter with bandwidth of 0.05-100Hz, the auto-balancing circuit and the saturation-calibrating circuit to eliminate baseline wandering, ECG signal sampled at 240 samples/sec is converted to the digital signal. We use a linear recursive filter and preprocessing algorithm to detect the ECG parameters which are QRS complex, and Q-R-T points, ST-level, HR, QT interval. The long-term acquired ECG signals and diagnostic parameters are compressed by the MFan(Modified Fan) and the delta modulation method. To easily interface with the PC based analyzer program which is operated in DOS and Windows, the compressed data, that are compatible to FFS(flash file system) format, are stored at the flash memory card with SBF(symmetric block format).

  • PDF

A Study on the Implementation of Ambulatory Monitoring System Using Wireless Data Communication Network (무선 데이터 통신망을 이용한 보행형 감시 시스템 개발에 관한 연구)

  • Go, Seong-Il;Kim, Yeong-Gil
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.75-80
    • /
    • 1999
  • Since a Holter monitor records a patients' ECG when he is in motion, it can monitor complex heart disease effectively. But it can not handle a sudden heart disease because the diagnosis process will be done only after 24 hours. So in this study, a model of ambulatory monitoring system using wireless data communication network is proposed. And a mobile ECG equipment and a doctors' terminal are developed for the proposed system implementation. As a result, we can evaluate that the proposed ambulatory monitoring system is suitable for the management of ambulatory patients who may be at risk form sudden cardiac abnormalities.

  • PDF

A Modification of Maze III Procedure to Improve Left Atrial Function (좌심방 기능회복을 위한 변형된 Maze III술식의 임상 분석)

  • 이재원;송태승;주석중;이상권;신재균;송명근
    • Journal of Chest Surgery
    • /
    • v.32 no.10
    • /
    • pp.903-909
    • /
    • 1999
  • Background: The current study was undertaken to investigate the results of a modification in the conventional Maze III Procedure devised by the authors. The aim of the technical modification was in improving the left atrial contractility. Material and Method: Between July 1997 and December 1998, 34 patients with chronic atrial fibrillation for more than 1 year duration underwent a modified Maze III procedure. The assessment of the left atrial function was made by various echocardiographic measurements and SA nodal recovery was evaluated by HRV Holter monitoring. Result: All 34 patients were in sinus rhythm. On echocardiography, right atrial contraction was detected in 32 patients(94.1%) and left atrial contraction in 33 patients(97.1%). The echocardiographic A wave at 1, 6, and 12 months or more were 50.5$\pm$31.5, 62.1$\pm$25.1, 66$\pm$20.6 cm/sec, respectively, and the E wave measurements at the same time points were 152$\pm$31.1, 134.4$\pm$35.2, 133$\pm$27.5 cm/sec. The corresponding A/E ratios were 0.32$\pm$0.13, 0.48$\pm$0.18, 0.5$\pm$0.15, showing a rising trend. Treadmill evaluation at 6 months showed a mean 82% increase in heart rate after excising, and the SDNN and SDANN upon HRV Holter at 1 and 3 months postoperatively were 65.3$\pm$28.1/87.8$\pm$27.2 ms, and 60.0$\pm$24.1/83.4$\pm$25.7 ms, respectively, showing a predoinant autonomic recovery in the parasympathetic system(PSDNN = 0.01, PSDANN =0.015). Conclusion: The results of our data suggest that the current modification in the conventional Maze III Procedure was efective in enhancing the postoperative left atrial contractility.

  • PDF

A Case of Disappearing Symptoms Developed Repetitively in a Complete Atrioventricular Block Patient Implanted Bipolar Permanent Pacemaker After Converting It into Unipolar System (완전방실블록 환자에서 쌍극의 영구박동기를 이식후 반복 발생된 증상이 단극으로 전환후 증상이 소실된 예)

  • Kweon, Jun-Young;Choi, Kyo-Won;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.1
    • /
    • pp.181-185
    • /
    • 1994
  • Pacemaker malfunctions are secondary to alterations of the preset pacing rate, irregular pacing failure of sensing, failure of cardiac capture or depolarization, and various combinations of these events. A 76 years old male patient was admitted due to pacemaker malfunction. 2 years ago, he was diagnosed as complete atrioventricular block. And then bipolar permanent pacemaker was implanted. Since then syncopal attack developed repetitivly. 12 lead ECG and 24 hour holter moniter monitoring, revealed pacing and sensing failure, thus we converted bipolar system into unipolar system. Since then syncopal attack did not developed again.

  • PDF

A Study on the assessment of stress using Wireless ECG (무선 심전도측정을 통한 스트레스 평가에 관한 연구)

  • Lim, Chae-Young;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.17-23
    • /
    • 2011
  • In this paper, daily life stress monitoring system is proposed. The proposed wireless ECG module, reducing the noise and increasing the size of signal, amplification circuit was designed for. Using HRV(Heart Rate Variability), extracted by measuring R-wave, stress diagnostic algorithms to assess the stress of human emotion were developed. For monitoring the activities, the proposed system is consist of small rectangular size for portable and by simple measurement it is possible to measure at any time. Through experiments, the proposed approach to represent user's stress level can be confirmed. Through that, it can see appropriate structure to obtain R-wave for stress assess as well as high resemblance to the clinical electrocardiogram. In this paper, performed experiments was developed nonrestraint measuring and wearable wireless biometric scanner that is able to monitor the heart's electrical activity of everyday life.Using this, the algorithm system, that is able to assess stress index through time-domain and frequency-domain analysis of the front and the rear of performing stress load protocol, was developed,

Permanent Sprayed Concrete Tunnel Linings Waterproofed with Bonded Membranes. A Review of the Current State-of-the-art for Hard Rock Conditions

  • Holter, K.G.
    • Magazine of korean Tunnelling and Underground Space Association
    • /
    • v.21 no.2
    • /
    • pp.103-116
    • /
    • 2019
  • Permanent sprayed concrete tunnel linings waterproofed with bonded membranes have been used at a number of important traffic projects over the last decade. Research has been carried out in several teams in order to increase the understanding of the function, properties and behavior of such linings under different loading and boundary conditions. The basic layout of this lining gives fundamental different system properties compared to the traditional lining systems. The main differences pertain to the groundwater exposure and the resulting hydraulic loading, the response of the concrete and membrane materials to this loading, as well as the geomechanically induced loading of the lining structure. The current understanding of the function and properties of such lining structures is presented in the paper based on review of recent research carried out in Norway, as well as field observations and monitoring carried over a several years. The influence of the water exposure on the final condition of the concrete and membrane materials has proven to be of vital importance for proper material testing and acceptance, assessments of the mechanical contribution of the bonded membrane, as well as assessments of the longterm durability of such linings. Obtaining realistic material parameters for the concrete and membrane materials subject to the boundary conditions posed by the groundwater exposure in an undrained structure is emphasized. Finally, some recent results from currently ongoing research on such linings, particularly the hydraulic response of the rock mass and the long term behavior of the concrete and membrane materials are presented.