• 제목/요약/키워드: Holter monitoring system

검색결과 7건 처리시간 0.028초

Evaluation of the Diagnostic Performance and Efficacy of Wearable Electrocardiogram Monitoring for Arrhythmia Detection after Cardiac Surgery

  • Seungji Hyun;Seungwook Lee;Yu Sun Hong;Sang-hyun Lim;Do Jung Kim
    • Journal of Chest Surgery
    • /
    • 제57권2호
    • /
    • pp.205-212
    • /
    • 2024
  • Background: Postoperative atrial fibrillation (A-fib) is a serious complication of cardiac surgery that is associated with increased mortality and morbidity. Traditional 24-hour Holter monitors have limitations, which have prompted the development of innovative wearable electrocardiogram (ECG) monitoring devices. This study assessed a patch-type wearable ECG device (MobiCARE-MC100) for monitoring A-fib in patients undergoing cardiac surgery and compared it with 24-hour Holter ECG monitoring. Methods: This was a single-center, prospective, investigator-initiated cohort study that included 39 patients who underwent cardiac surgery between July 2021 and June 2022. Patients underwent simultaneous monitoring with both conventional Holter and patchtype ECG devices for 24 hours. The Holter device was then removed, and patch-type monitoring continued for an additional 48 hours, to determine whether extended monitoring provided benefits in the detection of A-fib. Results: This 72-hour ECG monitoring study included 39 patients, with an average age of 62.2 years, comprising 29 men (74.4%) and 10 women (25.6%). In the initial 24 hours, both monitoring techniques identified the same number of paroxysmal A-fib in 7 out of 39 patients. After 24 hours of monitoring, during the additional 48-hour assessment using the patch-type ECG device, an increase in A-fib burden (9%→38%) was observed in 1 patient. Most patients reported no significant discomfort while using the MobiCARE device. Conclusion: In patients who underwent cardiac surgery, the mobiCARE device demonstrated diagnostic accuracy comparable to that of the conventional Holter monitoring system.

플레쉬 메모리 카드를 이용한 홀터 심전계의 설계 (Design of a Holter Monitoring System with Flash Memory Card)

  • 송근국;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권3호
    • /
    • pp.251-260
    • /
    • 1998
  • 홀터 심전계는 심장 이상으로 인한 급사 위험이 있는 환자를 위한 비관혈인 진단 장비이다. 본 연구에서는 일상생활 중에 심전도 데이터를 획득할 수 있도록 원칩 마이크로프로세서와 대용량메모리인 플레쉬 메모리(flash memory) 카드를 이용하여 2채널의 홀터 심전계를 설계하였다. 시스템 하드웨어는 크게 원칩 마이크로프로세서(68HC11E9)의 아날로그 심전도 처리회로, 플레쉬 메모리 카드로 구성하였다. 아날로그 심전도 처리회로는 250,500,1000의 이득을 갖는 증폭기와 0.05-100Hz의 대역폭을 갖는 대역통과 필터, 호흡으로 인한 기저선의 이동을 제거하기 위한 auto-balancing 회로와 포화-보정회로를 사용하였다. 심전도 신호는 240샘플/초 샘플링하여 A/D 변환하였다. 심전도는 필터링 및 전처리 과정을 통하여 특징점인 Q-R-T파를 검출하고, 이를 근거로 템플리트 생성, ST레벨, 심박수, QT간격 측정과 부정맥을 검출하였다. 또한 장시간동안의 심전도 데이터와 측정된 진단파라미터를 저장하기 위해 실시간 압축 알고리즘인 MFan과 delta modulation 방법을 이용하여 데이터를 압축, 저장하였다. 20M 바이트 용량의 플레쉬 메모리 카드에 기록된 데이터는 PC의 DOS나 Windows 환경의 ambulatory monitoring 분석시스템과 쉽게 인터페이스가 가능하도록 FFS(Flash File System)의 호환 가능한 SBF(Symetric Block format)포맷으로 저장하여 분석시스템에서 데이터 처리 및 관리할 수 있게 하였다.

  • PDF

무선 데이터 통신망을 이용한 보행형 감시 시스템 개발에 관한 연구 (A Study on the Implementation of Ambulatory Monitoring System Using Wireless Data Communication Network)

  • 고성일;김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.75-80
    • /
    • 1999
  • 홀터 심전계는 일반 심전계와 달리 활동중의 심전도를 기록하므로서 복잡한 심장질환을 효과적으로 모니터링할 수 있으나 24시간 동안의 심전도를 수집하여 진단하기 때문에 급작스런 심장질환에 대해서는 대처할 수 없다. 따라서 본 논문에서는 홀터 심전계와 같은 이동형 심전도 단말기에 900Mhz 대역을 사용하는 부선 데이터 통신망 인터페이스를 첨가하여 심장 이상으로 인한 급사위험이 있는 환자를 감시${\cdot}$관리할 수 있는 보행형 감시 시스템 모델을 제안하고 이동형 심전도 단말기와 담당 의사를 위한 휴대형 단말기를 구현함으로써 무선 데이터 통신망을 이용한 보행형 감시 시스템이 구현될 수 있음을 검증하였다.

  • PDF

좌심방 기능회복을 위한 변형된 Maze III술식의 임상 분석 (A Modification of Maze III Procedure to Improve Left Atrial Function)

  • 이재원;송태승;주석중;이상권;신재균;송명근
    • Journal of Chest Surgery
    • /
    • 제32권10호
    • /
    • pp.903-909
    • /
    • 1999
  • Background: The current study was undertaken to investigate the results of a modification in the conventional Maze III Procedure devised by the authors. The aim of the technical modification was in improving the left atrial contractility. Material and Method: Between July 1997 and December 1998, 34 patients with chronic atrial fibrillation for more than 1 year duration underwent a modified Maze III procedure. The assessment of the left atrial function was made by various echocardiographic measurements and SA nodal recovery was evaluated by HRV Holter monitoring. Result: All 34 patients were in sinus rhythm. On echocardiography, right atrial contraction was detected in 32 patients(94.1%) and left atrial contraction in 33 patients(97.1%). The echocardiographic A wave at 1, 6, and 12 months or more were 50.5$\pm$31.5, 62.1$\pm$25.1, 66$\pm$20.6 cm/sec, respectively, and the E wave measurements at the same time points were 152$\pm$31.1, 134.4$\pm$35.2, 133$\pm$27.5 cm/sec. The corresponding A/E ratios were 0.32$\pm$0.13, 0.48$\pm$0.18, 0.5$\pm$0.15, showing a rising trend. Treadmill evaluation at 6 months showed a mean 82% increase in heart rate after excising, and the SDNN and SDANN upon HRV Holter at 1 and 3 months postoperatively were 65.3$\pm$28.1/87.8$\pm$27.2 ms, and 60.0$\pm$24.1/83.4$\pm$25.7 ms, respectively, showing a predoinant autonomic recovery in the parasympathetic system(PSDNN = 0.01, PSDANN =0.015). Conclusion: The results of our data suggest that the current modification in the conventional Maze III Procedure was efective in enhancing the postoperative left atrial contractility.

  • PDF

완전방실블록 환자에서 쌍극의 영구박동기를 이식후 반복 발생된 증상이 단극으로 전환후 증상이 소실된 예 (A Case of Disappearing Symptoms Developed Repetitively in a Complete Atrioventricular Block Patient Implanted Bipolar Permanent Pacemaker After Converting It into Unipolar System)

  • 권준영;최교원;신동구;김영조;심봉섭;이현우
    • Journal of Yeungnam Medical Science
    • /
    • 제11권1호
    • /
    • pp.181-185
    • /
    • 1994
  • 저자들은 완전방실블록 환자에서 쌍극의 영구심장박동기를 이식후에도 계속되는 실신발작을 보여 단극의 영구심장박동기로 바꾼 후 그 증상이 소실된 예를 경험하였기에 이를 보고하는 바이다.

  • PDF

무선 심전도측정을 통한 스트레스 평가에 관한 연구 (A Study on the assessment of stress using Wireless ECG)

  • 임채영;김경호
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권2호
    • /
    • pp.17-23
    • /
    • 2011
  • 본 연구에서는 일상생활 속에서의 심전도를 측정하여 HRV(Heart Rate Variability)를 모니터링 하며 스트레스를 추정할 수 있는 시스템을 제안한다. 제안된 무선 생체 측정기 모듈은 전처리필터와 BFP사용으로 잡음은 감소 시키면서 신호의 크기는 증가시키기는 회로를 설계하였고, ECG를 측정하여 R-wave를 추출하고 이를 통한 HRV로 인간의 감성 중 스트레스를 평가하는 알고리즘을 개발하였다. 또한 무선 생체 측정기 시스템은 활동 모니터링을 위해 휴대하기 편한 사각형의 작은 사이즈로 구성되며 측정방법이 간단하여 언제든지 측정이 가능하다. 실험을 통해서 취득한 사용자의 HRV 정보는 스트레스 평가 지수 도출 알고리즘을 통한 스트레스를 추정할 수 있으며 스트레스 부하 프로토콜을 수행 한 전후를 비교 분석하여 많은 파라미터에서 유의미한 차이가 나타났다. 본 연구에서 수행된 실험은 일상생활 중에 심장의 전기 활동을 모니터링 할 수 있는무선 생체측정기를 개발하였으며 이를 이용하여 시간영역 분석 및 주파수 영역 분석을 통하여 스트레스 지수를 평가 할 수 있는 알고리즘 시스템은 건강 모니터링 시스템으로 활용도가 높을 것으로 기대된다.

Permanent Sprayed Concrete Tunnel Linings Waterproofed with Bonded Membranes. A Review of the Current State-of-the-art for Hard Rock Conditions

  • Holter, K.G.
    • 자연, 터널 그리고 지하공간
    • /
    • 제21권2호
    • /
    • pp.103-116
    • /
    • 2019
  • Permanent sprayed concrete tunnel linings waterproofed with bonded membranes have been used at a number of important traffic projects over the last decade. Research has been carried out in several teams in order to increase the understanding of the function, properties and behavior of such linings under different loading and boundary conditions. The basic layout of this lining gives fundamental different system properties compared to the traditional lining systems. The main differences pertain to the groundwater exposure and the resulting hydraulic loading, the response of the concrete and membrane materials to this loading, as well as the geomechanically induced loading of the lining structure. The current understanding of the function and properties of such lining structures is presented in the paper based on review of recent research carried out in Norway, as well as field observations and monitoring carried over a several years. The influence of the water exposure on the final condition of the concrete and membrane materials has proven to be of vital importance for proper material testing and acceptance, assessments of the mechanical contribution of the bonded membrane, as well as assessments of the longterm durability of such linings. Obtaining realistic material parameters for the concrete and membrane materials subject to the boundary conditions posed by the groundwater exposure in an undrained structure is emphasized. Finally, some recent results from currently ongoing research on such linings, particularly the hydraulic response of the rock mass and the long term behavior of the concrete and membrane materials are presented.