• 제목/요약/키워드: Holographic interferometry

검색결과 86건 처리시간 0.028초

홀로그래피 간섭계를 이용한 미소변위 측정 (Small Displacement Measurement by Holographic Interferometry)

  • 이해중;황운봉;박현철
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.864-872
    • /
    • 1992
  • 본 연구에서는 이중노출 홀로그래피 간섭계의 원리를 이용하여 임의의 2차원 적 변형에 있어서 면외 변위와 면변위(in-plane displacement) 각각에 대한 홀로그램 을 제작하고 이를 컴퓨터에 입력하여 간섭무늬를 해석함으로써 변위와 변형률의 정량 화를 시도하였다.

Modified Protraction Headgear를 이용한 상악골 전방 견인시 악안면골의 초기반응에 관한 Holographic Interferometry 연구 (A STUDY OF HOLOGRAPHIC INTERFEROMETRY ON THE INITIAL REACTION OF MAXILLOFACIAL COMPLEX TO THE MAXILLARY PROTRACTION USING THE ANTENNA TYPE MODIFIED PROTRACTION HEAD GEAR)

  • 이공근;유영규
    • 대한치과교정학회지
    • /
    • 제22권3호
    • /
    • pp.531-556
    • /
    • 1992
  • The majority of the commonly used protraction headgears for the protraction of small and/or retropositioned maxilla not allow a change in the point of force application or direction of the force delivery to attain predictable results because of the position of the upper and lower lips to avoid discomfort to the patient. The purpose of this study was to investigate the initial reaction of maxillofacial complex according to the change of force variables such as direction and point of force application with designing an antenna type-modified protraction head gear. A macerated human skull with well aligned upper teeth was used to experimental model and the investigation was done by double exposure holographic interferometry. Fringe patterns of each protraction conditions were compared and analized. The results were as follows. (Frontal view) 1. The Counterclockwise rotation of the maxilla was showed by parallel protraction to occlusal plane and the fringe was decreased in number as higher point of force application. 2. Generally, the number of fringe was increased in 500gm of protraction force than in 300gm. 3. When apply the protraction force to the maxilla with rapid palatal expansion, the direction of fringe patterns was differed from the protraction without expansion. 4. In most of cases, the counterclockwise rotation was decreased in case of the direction of the force is $20^{\circ}$ downward to occlusal plane compared to the parallel direction. 5. At the point of force application is 15mm above and the direction of force is 20 downward to occlusal plane , the translation of the maxillary complex was showed. (Lateral view) 6. The direction of fringe patterns of the facial bones were differed each other by the sutures, and showed almost parallel when apply the 300gm and 500gm of protraction force. 7. In case of rapid palatal expansion with protraction of the maxilla, the fringe patterns between the maxillary area and the area from the posterior of the maxillary first molar to the pterygomaxillary fissure were differed. In case without rapid palatal expansion, the changes of direction and point of the force application did not affect to the direction and the number of the fringe patterns.

  • PDF

2-step Phase-shifting Digital Holographic Optical Encryption and Error Analysis

  • Jeon, Seok-Hee;Gil, Sang-Keun
    • Journal of the Optical Society of Korea
    • /
    • 제15권3호
    • /
    • pp.244-251
    • /
    • 2011
  • We propose a new 2-step phase-shifting digital holographic optical encryption technique and analyze tolerance error for this cipher system. 2-step phase-shifting digital holograms are acquired by moving the PZT mirror with phase step of 0 or ${\pi}$/2 in the reference beam path of the Mach-Zehnder type interferometer. Digital hologram with the encrypted information is Fourier transform hologram and is recorded on CCD camera with 256 gray-level quantized intensities. The decryption performance of binary bit data and image data is analyzed by considering error factors. One of the most important errors is quantization error in detecting the digital hologram intensity on CCD. The more the number of quantization error pixels and the variation of gray-level increase, the more the number of error bits increases for decryption. Computer experiments show the results to be carried out encryption and decryption with the proposed method and the graph to analyze the tolerance of the quantization error in the system.

이중펄스레이저 홀로그래픽 간섭법을 이용한 평판의 탄성파 전파특성에 관한 연구 (A Study on the Characteristics of Elastic Wave Propagation in Plates Using Double Pulsed Laser Holographic Interferometry)

  • 이기백;나종문;김정훈
    • 대한기계학회논문집A
    • /
    • 제20권10호
    • /
    • pp.3211-3223
    • /
    • 1996
  • In this paper, the propagation of elastic wave generated by loading impact to plates made of isotropic of anisotropic material was studied. And the influence of boundary conditions (free or clamped edge) upon the reflection of elastic wave was anlyzed. Also, double exposure holographic interferometer using ruby pulse laser was formed in order to investigate transient waves. Before the elasitc wave was reflected from the edges, the elastic wave of isotropic plate such as aluminum plate showed circular interferometric fringe pattern, whereas that of anisotropic plate such as epoxy composite laminates showed elliptical one. And the transverse displacement curves obtained from experiment and theory for both plates agreed well. Also, the waves reflected from the boundary edges showed much differences according to the boundary condition of edges.

Determining Two-Sided Surface Profiles of Micro-Optical Elements Using a Dual-Wavelength Digital Holographic Microscope With Liquids

  • Lee, Hong Seok;Shin, Sanghoon;Lee, Heonjoo;Yu, Younghun
    • Journal of the Optical Society of Korea
    • /
    • 제18권5호
    • /
    • pp.495-499
    • /
    • 2014
  • In this paper, a method is proposed for simultaneously measuring the front and back surface profiles of transparent micro-optical components. The proposed method combines a dual-wavelength digital holographic microscope with liquids to record holograms at different wavelengths, and then numerically reconstructs the three-dimensional phase information to image the front and back sides of the sample. A theoretical model is proposed to determine the surface information, and imaging of an achromatic lens is demonstrated experimentally. Unlike conventional interferometry, our proposed method supports nondestructive measurement and direct observation of both front and back profiles of micro-optical elements.

앞이 무딘 물체에서 반사되는 약한 충격파 (Weak Shock Waves Reflected from a Blunt Body)

  • 장세명;장근식
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.901-910
    • /
    • 1999
  • Investigated In this paper is the shock reflection from a blunt body, In particular, a circular cylinder of 20 mm diameter, for the weak shock impinging in the range 1<$M_s$ <2. Pressure and shock speed are measured for various shock strengths. Double-pulse holographic interferograms are taken to study the unsteady flow field at $M_s=1.34$. These experimental results are, in overall, well compared with the unstructured adaptive finite volume computation of the Euler equations performed in this study. Correlation of incident and reflected shocks and shock-shock locus obtained by experiment, computation, and theory are presented in parallel.

위상이동법과 시간평균법의 면내변위 측정 비교 (Comparison of In-Plane Measurement of Phase-Shifting with Time-Average Method)

  • 김경석;김동일;정현철;강기수;이찬우;양승필;장순석
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.53-58
    • /
    • 1999
  • Even I the Electronic Speckle Pattern Interferometry(ESPI) method that measure the strain of object within wavelength of light is less visibility than Holographic Interferometry(HI) method, the merits of application, convenience and time-save have made the method practical in industry. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement, due to irregular intensity and shake of phase. Recently, in order to solve this problem, phase shifting method have been proposed. In this method, the path of reference light in interference is shifted to make improvement in distinction and precision. But this method includes too many noise, caused by the problem of relationship between object and phase. Therefore, a method to reduce noise muse be introduced. In this paper, least square fitting method is proposed. As results, the phase-map is influenced by precise phase shifting and current of notes and speckle pattern obtained by phase shifting method is improved on the existing method driven from time-average method.

  • PDF

위상천이가법에 의한 디지털 홀로그래피 마이크로스코피에 관한 연구 (Digital Holographic microscopy based on phase shifting technique)

  • 박광희;최평석;은재정
    • 융합신호처리학회논문지
    • /
    • 제12권3호
    • /
    • pp.181-187
    • /
    • 2011
  • 본 논문에서는 홀로그램정보의 손실이 없고, CCD 화소면의 최대 활용이 가능한 in-line 형태의 광학계를 구성하고, 보다 향상된 위상 천이법을 토대로 디지털 in-line 홀로그래피 마이크로스코피를 구현하였다 이러한 구성방식으로 디지털 홀로그래피의 최대 문제인 0차 회절 항에 의한 DC잡음과 in-line 홀로그래피에서 나타나는 트윈 이미지가 효율적으로 제거됨을 실험적으로 보였고, 위상 맵핑을 통해 계량적으로 분석하였다. 또한 광학장치 컨트롤과 영상처리가 연동하여 실시간적으로 이루어지므로, 본 논문에서 연구한 DHM 방식은 앞으로 미세분석을 위한 삼차원 현미경법에 많은 응용이 이루어 질것으로 기대된다.

Statistical Analysis of 3D Volume of Red Blood Cells with Different Shapes via Digital Holographic Microscopy

  • Yi, Faliu;Lee, Chung-Ghiu;Moon, In-Kyu
    • Journal of the Optical Society of Korea
    • /
    • 제16권2호
    • /
    • pp.115-120
    • /
    • 2012
  • In this paper, we present a method to automatically quantify the three-dimensional (3D) volume of red blood cells (RBCs) using off-axis digital holographic microscopy. The RBCs digital holograms are recorded via a CCD camera using an off-axis interferometry setup. The RBCs' phase image is reconstructed from the recorded off-axis digital hologram by a computational reconstruction algorithm. The watershed segmentation algorithm is applied to the reconstructed phase image to remove background parts and obtain clear targets in the phase image with many single RBCs. After segmenting the reconstructed RBCs' phase image, all single RBCs are extracted, and the 3D volume of each single RBC is then measured with the surface area and the phase values of the corresponding RBC. In order to demonstrate the feasibility of the proposed method to automatically calculate the 3D volume of RBC, two typical shapes of RBCs, i.e., stomatocyte/discocyte, are tested via experiments. Statistical distributions of 3D volume for each class of RBC are generated by using our algorithm. Statistical hypothesis testing is conducted to investigate the difference between the statistical distributions for the two typical shapes of RBCs. Our experimental results illustrate that our study opens the possibility of automated quantitative analysis of 3D volume in various types of RBCs.

시간 평균 ESPI를 이용한 진동 물체의 모우드 형태의 계측 (Measurement of Vibration Mode Shapes Using Time Average ESPI)

  • 강영준;최장섭
    • 한국정밀공학회지
    • /
    • 제13권2호
    • /
    • pp.84-93
    • /
    • 1996
  • Non-destructive inspection techniques using laser have been broading their application areas as well as growing their measurement skills together with the rapid development of circumferential technology like fiber optics, computer and image processing. The ESPI technique is already on the stage of on-line testing with commercial products in developed country nations. Especially, this technique is expected to be applied to the nuclear industry, automobile and aerospace because it is proper for the vibration measurement and it can be applied to objects of a high temperature. This paper describes the use of the ESPI system for measuring vibration patterns on the reflecting objects. Using this system, high-quality Jo fringes for identifying mode shapes are displayed. A bias vibration is introduced into the reference beam to shift the Jo fringes so that fringe shift algorithms can be used to determine vibration amplitude. Using this method, amplitude fields for vibrating objects were obtained directly from the time-average interferograms recorded by the ESPI system.

  • PDF