• Title/Summary/Keyword: Hold time

Search Result 626, Processing Time 0.026 seconds

Development of a Breath Control Training System for Breath-Hold Techniques and Respiratory-Gated Radiation Therapy

  • Hyung Jin Choun;Jung-in Kim;Jong Min Park;Jaeman Son
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.136-141
    • /
    • 2022
  • Purpose: This study aimed to develop a breath control training system for breath-hold technique and respiratory-gated radiation therapy wherein the patients can learn breath-hold techniques in their convenient environment. Methods: The breath control training system comprises a sensor device and software. The sensor device uses a loadcell sensor and an adjustable strap around the chest to acquire respiratory signals. The device connects via Bluetooth to a computer where the software is installed. The software visualizes the respiratory signal in near real-time with a graph. The developed system can signal patients through visual (software), auditory (buzzer), and tactile (vibrator) stimulation when breath-holding starts. A motion phantom was used to test the basic functions of the developed breath control training system. The relative standard deviation of the maxima of the emulated free breathing data was calculated. Moreover, a relative standard deviation of a breath-holding region was calculated for the simulated breath-holding data. Results: The average force of the maxima was 487.71 N, and the relative standard deviation was 4.8%, while the average force of the breath hold region was 398.5 N, and the relative standard deviation was 1.8%. The data acquired through the sensor was consistent with the motion created by the motion phantom. Conclusions: We have developed a breath control training system comprising a sensor device and software that allow patients to learn breath-hold techniques in their convenient environment.

Improvement of Modulation Index in 3-phase Inverters using Shunt Resistors (션트저항을 이용한 3상 인버터의 전압 변조지수 증대)

  • Kim, Jung-Dae;Choi, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.3
    • /
    • pp.374-382
    • /
    • 2018
  • This paper has done a hardware-based approach to increase the modulation index in 3-phase inverters, unlike the conventional software algorithm-based approaches. The minimum required time to measure the currents in a three-phase inverters with shunt resistors has also been analyzed. By the analysis, the longest time in minimum required time is AD conversion time. To shorten the minimum required time, this paper proposed a sample-and-hold(S/H) circuit implemented at the inverter current signal output to retain the current signal. When the linear operation region of an inverter with S/H was compared with that without it, the modulation index was increased by 7.8 %. Inverters with S/H circuits can employ the traditional software algorithms, such as the voltage injection method or current restoration method, and it will yield further increase the modulation index.

A study on optimization of injection molding of large thick LH type elastic frame (대형 후육 LH형 탄성구조 프레임의 사출성형 최적화에 관한 연구)

  • Lee, Sung-Hee
    • Design & Manufacturing
    • /
    • v.16 no.1
    • /
    • pp.62-69
    • /
    • 2022
  • In the present study, the injection molding optimization of a large thick LH type elastic frames for the reduction of warpage was performed. Two kinds of fine and coarse finite element models were prepared to investigate the efficiency of analysis time and quality on simulation results. In order to derive injection molding conditions that can minimize distortion of parts, it was investigated that the effects of mold temperature, resin temperature, injection time, hold pressure switching time, holding pressure and the hold time on deformation characteristics using the design of experiments. The main influential factors on the warpage were found from the optimization simulation and the geometry data of the warpage result was converted into an initial model for injection simulation. It was shown that a coarse model with good mesh quality could be adapted for mold design since the total analysis time using the proposed model was reduced to 1/10. The suggested inversed warpage model produced the best minimized result of warpage.

Assessment of Left Ventricular Function with Single Breath-Hold Magnetic Resonance Cine Imaging in Patients with Arrhythmia

  • Bak, So Hyeon;Kim, Sung Mok;Park, Sung-Ji;Kim, Min-Ji;Choe, Yeon Hyeon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.1
    • /
    • pp.20-27
    • /
    • 2017
  • Purpose: To evaluate quantification results of single breath-hold (SBH) magnetic resonance (MR) cine imaging compared to results of conventional multiple breath-hold (MBH) technique for left ventricular (LV) function in patients with cardiac arrhythmia. Materials and Methods: MR images of patients with arrhythmia who underwent MBH and SBH cine imaging at the same time on a 1.5T MR scanner were retrospectively reviewed. Both SBH and MBH cine imaging were performed with balanced steady state free precession. SBH scans were acquired using temporal parallel acquisition technique (TPAT). Fifty patients ($65.4{\pm}12.3years$, 72% men) were included. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), myocardial mass, and LV regional wall motion were evaluated. Results: EF, myocardial mass, and regional wall motion were not significantly different between SBH and MBH acquisition techniques (all P-values > 0.05). EDV, ESV, and SV were significant difference between the two techniques. These parameters for SBH cine imaging with TPAT tended to lower than those in MBH. EF and myocardial mass of SBH cine imaging with TPAT showed good correlation with values of MBH cine imaging in Passing-Bablok regression charts and Bland-Altman plots. However, SBH imaging required significantly shorter acquisition time than MBH cine imaging ($15{\pm}7sec$ vs. $293{\pm}104sec$, P < 0.001). Conclusion: SBH cine imaging with TPAT permits shorter acquisition time with assessment results of global and regional LV function comparable to those with MBH cine imaging in patients with arrhythmia.

A Study of the Effect of Stress Waveform on the Behavior of High Temp. Fatigue Crack Propagation Using J Parameters (J파라미터를 이용한 고온피로균열전파 거동에 미치는 응력파형 영향의 연구)

  • Hur, Chung-Weon;Park, Won-Jo
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.8-12
    • /
    • 2000
  • The fatigue crack propagation tests were performed in triangular and holding-time stress waveforms at $650^{\circ}C$. The behavior of fatigue crack propagation was investigated according to waveform. The analysis of high temperature fatigue crack propagation by the stress intensity factor range ${\Delta}K$, elastic fracture mechanics parameter, was not available. The behaviors of high temperature fatigue crack propagation by the J-integral(${\Delta}J_f$, J' and ${\Delta}J_c$), elasto-plastic fracture mechanics parameter, were investigated in a number of stress waveforms. The fast-fast waveform exhibited cycle-dependent(fatigue type), the slow-fast and the hold time with 500sec waveforms appear to be time-dependent(creep type) and the fast-slow and the hold time with 5, 25sec waveforms exhibited conbined behavior of both types(fatigue-creep conbined type).

  • PDF

A study on Linear Pattern Fabrication of Plate-type PC (PC소재의 선형 패턴 제작에 관한 연구)

  • Joung, Y.N.;Lee, E.K.;Kang, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.277-280
    • /
    • 2008
  • Recently, a demand of nano/micro patterned polymer for display or biochip has been rising. Then many studies have been carried out. Nano/micro-embossing is a deformation process where the workpiece materials is heated to permit easier material flow and then forced over a planar patterned tool. In this work, the hot-emboss process is performed with different forming conditions; forming temperature, load, press hold time, to get the proper condition for linear pattern fabrication on plated-type polymers (PC). Replicated pattern depth increases in proportion to the forming temperature, load and time. Reduction of the workpiece thickness increases according to press hold time. In process of time, reduction ratio of workpiece thickness decreases because of surface area increment of the workpiece and pressure decline on it.

  • PDF

A Study on a Minimizing Method of Baseline Wandering in ECG (심전도 기저선 변동의 최소화방법에 관한 연구)

  • Kim, Min-Kyu;Kim, Jang-Kyu;Lee, Ki-Young;Kim, Jung-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.48-50
    • /
    • 2006
  • In this paper, we propose a method to minimize the baseline wandering that make hard to detect R wave in ECG. This method uses a different signal between ECG and ascending slope tracing waves to minimize the baseline wandering. When the slope of ECG signal maintains the value or falls, the ascending slope tracing wave fellows ECG signal directly, and this wave holds that value of ECG signal when the slope begins to rises in a certain time(=hold time). After this hold time, this wave traces ECG signal again. To evaluate this minimizing method for baseline wandering, the experiments are carried out with 5 ECG data in the database of MIT/BIH. R waves in the proposed different signal are detected by using descending slope trace waves and compared with the annotation file. The results show that the proposed method Is sure to minimize the baseline wandering in ECG.

  • PDF

Taylor Series Based Discretization for Nonlinear Input-delay Systems (Taylor Series를 이용한 입력 시간지연 비선형 시스템 일반적인 이산화)

  • Park, Yu-Jin;Lim, Dae-Youn;Chong, Kil-To
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.17-25
    • /
    • 2012
  • A general discretization method for input-driven nonlinear continuous time-delay systems is proposed, which can be applied to general order sampling hold assumptions. It is based on a combination of Taylor series expansion and the theories of sampling and hold. The mathematical structure of the new discretization scheme is introduced in detail. The performance of the proposed discretization procedure is evaluated by two degrees of systems. The results show that the proposed scheme is applicable to control systems.

Uniqueness of an Optimal Run-up for a Steep Incline of a Train

  • Vu, Xuan
    • International Journal of Railway
    • /
    • v.2 no.2
    • /
    • pp.70-79
    • /
    • 2009
  • An optimal driving strategy of a train in a long journey on a nonsteep track has four phases: an initial power phase, a long hold speed phase, a coast phase and a final brake phase. The majority of the journey is speed holding. On a track with steep gradients, it becomes necessary to vary the strategy around steep sections of track because it is not possible to hold a constant steep on steep track. Instead we must interrupt the speed hold phase with a power phase. The aim of this paper is to show that there is a unique power phase that satisfies the necessary conditions for an optimal journey. The problem is developed and solved for various cases, from a simple single steep gradient to a complicated multiple steep gradient section. For each case, we construct a set of new conditions for optimality of the power phase that minimises the energy used during the power phase subject to a weighted time penalty. We then use the new necessary conditions to develop a calculate scheme for finding an optimal power phase for a steep incline. We also present an example to confirm the uniqueness of an optimal power phase.

  • PDF

A Study of Correlation between DCA and WHS in Fin-and-Tube Heat Exchanger (핀-관 열교환기에서 동적접촉각과 물맺힘량과의 상관관계에 관한 연구)

  • 황준현;고영환;신종민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.786-791
    • /
    • 2002
  • An experimental study on the behavior of the water hold-up by spraying of a fin-and-tube heat exchanger with regard to the surface characteristics, i.e., contact angles, was conducted. The dynamic contact angles (DCA) were measured, and water hold-up by spraying (WHS) was conducted in the experiment. It is found that heat exchanger surface characteristics, spray pressure, spray water temperature and heat exchanger surface temperature play an important role in WHS. In order to evaluate relationship between WHS and surface characteristics, test conditions are determined through a contour analysis. A correlation was proposed to predict WHS as a function of DCA. With its test efficiency and consuming time, the prediction method can be used to evaluate WHS performance.