• Title/Summary/Keyword: Ho:YAG Laser

Search Result 144, Processing Time 0.027 seconds

Laser Micro-machining technology for Fabrication of the Micro Thin-Film Inductors (초소형 박막 인덕터 제작을 위한 레이저 미세가공 기술 개발)

  • Ahn, Seong-Joon;Ahn, Seung-Joon;Kim, Dae-Wook;Kim, Ho-Seob;Kim, Cheol-Gi
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.3
    • /
    • pp.115-120
    • /
    • 2003
  • We have developed laser micro-machining technology for fabrication of the micro thin-film inductors. After the thin layers of FM/M/FM films were coated to the silicon substrate by using the conventional sputtering method, the new laser machining was applied to the patterning process that used to be carried out by the semiconductor lithography procedure. A CW Nd:YAG laser operating in TEM$\sub$00/ mode was actively Q-switched to obtain the very short pulse of 200 ns. The laser micro-machining process with pulse energy and repetition rate have been optimized as 5 mJ/pulse and 5 kHz, respectively, to obtain the line resolution as fine as 20 $\mu\textrm{m}$.

ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY AND TEMPERATURE CHANGES OF DENTIN (Er:YAG 레이저의 상아질 삭제효과 및 이에 따른 온도변화)

  • Im, Kwang-Ho;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.1
    • /
    • pp.32-44
    • /
    • 2001
  • The purpose of this study was to investigate the effects of Er : YAG laser on cutting efficacy and temperature changes of dentin. We used the dentin specimens of human premolars and molars which contain the physiologic saline and maintain the pulpal pressure in dentinal tubules. Each specimen was exposed to Er : YAG laser with non-contact handpiece type delivery system under different treatment condition of irradiation energy, pulse repetition rate, and exposure time. Two procedures were conducted by the presence of water flow during lasing. The specimens were grouped by thickness of dentin. We investigated the cavity pattern, volume, and temperature change of dentin specimen to determine the cutting efficacy and temperature rise of Er : YAG laser, and obtained following results. 1. Cutting volume of dentin was increased by increasing the irradiation energy, pulse repetition rate, and exposure time(P<0.05). 2. Margins of abulated cavities were sharp and clean and floors of cavities were conical in shape and showing smooth surfaces. Upper diameter of abulated cavities were increasing as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased. A few cracks were observed on abulated surfaces under treatment condition of laser parameter with 150mJ, 5Hz, and 5sec. 3. Temperature was increased as laser parameter of irradiation energy, pulse repetition rate, and exposure time were increased, and temperature rise was decreased as dentin thickness was increased(P<0.05). 4. Temperature rise was decreased under water flow compared with no water flow during laser exposure(P<0.05). From these results, we think that the method of using a Er:YAG laser would be effective and safe in cutting dentin for clinical application.

  • PDF

Design of an Nd:YAG Slab Structure for a High-power Zigzag Slab Laser Amplifier Based on a Wavefront Simulation

  • Shin, Jae Sung;Cha, Yong-Ho;Cha, Byung Heon
    • Current Optics and Photonics
    • /
    • v.3 no.3
    • /
    • pp.236-242
    • /
    • 2019
  • An Nd:YAG slab structure was designed for a high-power zigzag slab laser amplifier based on computational simulation of the wavefront distortion. For the simulation, the temperature distribution in the slab was calculated at first by thermal analysis. Then, the optical path length (OPL) was obtained by a ray tracing method for the corresponding refractive index variation inside the slab. After that, the OPL distribution of the double-pass amplified beam was calculated by summing the results obtained for the first and second passes. The amount of wavefront distortion was finally obtained as the peak-to-valley value of the OPL distribution. As a result of this study, the length and position of the gain medium were optimized by minimizing the transverse wavefront distortion. Under the optimized conditions, the transverse wavefront distortion of the double-pass amplified beam was less than $0.2{\mu}m$ for pump power of 14 kW.

SEM EVALUATION AND SHEAR BOND STRENGTH OF ER : YAG LASER IRRADIATION ON ENAMEL SURFACE (Er : YAG 레이저 조사가 법랑질 표면 변화와 전단강도에 미치는 영향)

  • Lim, Hyoung-Soo;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.374-382
    • /
    • 2001
  • The purpose of this study was to investigate the surface morphology and measure shear bond strength of Er : YAG lased enamel. To determine the most effective energy density of laser for improving bonding strength of human enamel, 24 specimen were lased from 30mJ to 150mJ at 1Hz used focused, defocused beam. After irradiation, the lased specimen were observed scanning electron microscope. To determine the resin shear bond strength of Er : YAG lased enamel, the 90 specimen were divided into 3 groups. The Control group was etched with 37% phosphoric acid for 15seconds and rinsed. Group 1 was only laser irradiaton(60mJ, 10Hz), Group 2 was irradiated as Group 1 regimen, followed 37% phosphoric acid etching. The following results were obtained: 1. In both focused and defocused Er : YAG lased enamel surface are similar to acid-etched enamel more than 60mJ in SEM evaluation. 2. The more increased laser energy, the more observed fissuring surface. 3. The highest mean shear bond strength value was observed in control group with the statistical significance(p<0.05) between all the other groups and the shear bond strength in group 1 was the lowest with significant difference among the other groups.

  • PDF

ER:YAG LASER-TREATED ENAMEL FOR PIT AND FISSURE SEALANT: A COMPARISON OF MICROLEAKAGE (Er:YAG 레이저를 이용한 법랑질 표면처리 후 치면열구전색재의 미세누출에 관한 평가)

  • Lee, Seon-Suk;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.597-605
    • /
    • 2006
  • It is introduced that pit and fissure sealant is the most universal and effective to prevent occlusal dental caries. In processing of being applied the pit and fissure sealant, the various kinds of methods are developed to remove organic matters, plaque, microflora and debris in the pit and fissure for increasing the rates of maintain the sealant. Recently, the Er:YAG laser has been used as a new enamel surface treatment method. The purpose of this thesis is compared whether that enamel surface treatment method is superior to other methods or not. 1. 100mJ 5Hz Er:YAG lased enamel surface was similar to acid-etched enamel in SEM evaluation. 2, Mechanical preparation showed decreased microleakage when compared with acid-etching only, but no significant differences in both method. 3. After laser and acid-etching method showed decreased microleakage when compared with acid-etching only.

  • PDF

Dynamic Quasi-Elastic Light Scattering Measurement of Biological Tissue

  • Youn, Jong-In;Lim, Do-Hyung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.169-173
    • /
    • 2007
  • During laser irradiation, mechanically deformed cartilage undergoes a temperature dependent phase transformation resulting in accelerated stress relaxation. Clinically, laser-assisted cartilage reshaping may be used to recreate the underlying cartilaginous framework in structures such as ear, larynx, trachea, and nose. Therefore, research and identification of the biophysical transformations in cartilage accompanying laser heating are valuable to identify critical laser dosimetry and phase transformation of cartilage for many clinical applications. quasi-elastic light scattering was investigated using Ho : YAG laser $(\lambda=2.12{\mu}m\;;\;t_p\sim450{\mu}s)$ and Nd:YAG Laser $(\lambda=1.32{\mu}m\;;\;t_p\sim700{\mu}s)$ for heating sources and He : Ne $(\lambda=632.8nm)$ laser, high-power diode pumped laser $(\lambda=532nm)$, and Ti : $Al_2O_3$ femtosecond laser $(\lambda=850nm)$ for light scattering sources. A spectrometer and infrared radiometric sensor were used to monitor the backscattered light spectrum and transient temperature changes from cartilage following laser irradiation. Analysis of the optical, thermal, and quasi-elastic light scattering properties may indicate internal dynamics of proteoglycan movement within the cartilage framework during laser irradiation.