This paper describes an electrochemical immunoassay for simple, fast and quantitative detection of a urinary hippuric acid which is one of major biological indicator in toluene-exposed humans. The electrochemical system of immunoassay was based on the directly osmium complex conjugated with hippuric acid. With the competition between free hippuric acid (HA) and the osmium-hippuric acid conjugate (Os-HA) to bind with antibody hippuric acid (Anti-HA) coated onto gold nanoparticles, the electrical signals were proportional to urinary hippuric acid (HA) in the range of 0.01-5 mg/mL which is enough range to be used for in-field or point-of-care (POC) diagnosis. The proposed electrochemical method can be extended to the applications to detect a wide range of different small molecules in the field of health care.
This study is assessed the urinary hippuric acid (HA) concentration in toluene-exposed workers. Toluene is widely used in the coating, printing, painting and petroleum industries. We analyzed the hippuric acid level of toluene-exposed workers (males: 198, females: 63) from 2008 to 2010 and examined the relationship between hippuric acid and the characteristics of their work. The measurements of the urinary hippuric acid were confirmed by high-performance liquid chromatography. Among the subjects, males had on average more work experience than females (males: 9.17 years, females: 4.45 years), but females showed a higher hippuric acid concentration levels than males (males: 0.26 g/L, females: 0.75 g/L). The mean of the HA concentration according to the age group was 0.19 g/L in 30's, 0.30 g/L in 40's, 0.54 g/L in 50's, 1.36 g/L in 60's. Those in their 60's had the highest concentration. The mean of HA concentration according to the type of work was 0.70 g/L for the coating, 0.52 g/L for the painting, and 0.16 g/L for the printing industries, revealing that the workers in the coating industry had the highest concentration. By the highest order, the mean of HA concentration by working period was as follows; less than 5 years, ${\leq}5\;years{\sim}<10\;years$. The factors that influence the HA concentration are not only how long one is exposed to toluene but also the type of work, worker's age, and their gender.
In this work, we describe an electrochemical immunosensor for simple, fast and quantitative detection of a urinary hippuric acid (HA). Urinary HA, of molecular weight 180 DA, is one of the major metabolites and biological indicators in toluene-exposed humans. Simple and ubiquitous monitoring of exposure to toluene is very important in occupational health care. We propose the electrochemical immunoassay based on the dopamine-antigen conjugate for detecting hippuric acid. Our electrochemical immunoassay system employs a conjugate of dopamine (DA) as an electrochemical active molecule and hippuric acid (HA) as an antigen. As an electrochemical aspect, dopamine (DA) containing two hydroxyl group can show excellent redox signal. Also, dopamine-tethered hippuric acid (DA-HA) shows the reversible redox signal in the immunoassay. The competition between HA and DA-HA generated electric signals proportional to HA concentration. The electrochemical immunoassay was performed with DA-HA on the screen printed carbon electrodes (SPCEs), and then applies the mixture antigen (HA) and HA-antibody. The electrical signals were proportional to HA in the range of 0.010~2.500 mg/mL which is enough range to be used for the point-of-care.
This study was carried out In Investigate the correlation between toluene In air and hippuric acid In human urine, which 1.: based on the results of the health check-in and the measure of working environment, was investigated for two years. The concentration of toluene in air for the five working places in Yang-San area were ranged from 39.05±10.31 ppm to 4.04±3.38ppm and the mean value of those was 16.89±14.76ppm. The mean value was 16.89±14.76ppm which is below the permissible limit of toluene. The concentration of hippuric acid(HA) In the worker's urine were between 0.47g/ℓ and 0.76g/ℓ. There was mutual correlation (Υ=0.94) between the concentration of toluene in air and that of hippuric acid in urine. In case of male workers, the mean value of hippurlc acid In urine was 0.56g/ f and the female workers was 0.57g/ℓ that showed higher than the male's. However, there was no relationship between the workshop and the distinction of sex. From the mean value of toluene in air(T) and that of hippuric acid(H), we obtained the formula, Η=0.3logΤ+0.235.
An electrochemical immunoassay based on osmium-hippuric acid (HA) conjugate films onto the electrode is presented for the detection of urinary HA. This is the first report on the use of the oxidative electropolymerization of 5-amino-1,10-phenanthroline (5-$NH_2$-phen) for immobilizing an antigen, osmium-conjugated HA. As a redox mediator, [Os(5-amino-1,10-phenanthroline)$_2$(4-aminomethylpyridine-HA)Cl]$^{+/2+}$ (Os-phen-HA) was successfully synthesized and electropolymerized onto the screen-printed carbon electrodes (SPCEs). The interaction between osmium-HA conjugate films and antibody-HA ($anti$-HA) was performed by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The electrical signals were linearly proportional to urinary HA in the range of 0.1-5.0 mg/mL, which is sufficient for use as an immunosensor using a cutoff concentration of 2.0 mg/mL in urine samples. The proposed electrochemical immunoassay method can be extended to various applications for detecting a wide range of different small antigens in the health care area.
The coordination of pyridyl-N to pentacyanoferrate for the detection of small organic antigens in solution is presented. The unique contribution of this paper is the direct conjugation of pyridyl-N in small organic antigens to pentacyanoferrate. Pentacyanoferrate is promising as an electrochemical label owing to its good electro-chemical properties, which can be utilized to generate an electrical signal in homogeneous electrochemical immunoassays. The facilely synthesized pyridyl-N to pentacyanoferrate was characterized by the electrochemical and spectroscopic methods. Hippuric acid (HA) has been detected competitively on the interaction of free HA and pentacyanoferrate-(4-aminomethylpyridine-hippuric acid) (Fe-HA) to its antibody, with the detection limit of 0.50 ${\mu}g\;mL^{-1}$. While pentacyanoferrate-based immunoassay is in its simplicity and infancy, the proposed immunoassay offers attractive opportunities for developing pyridyl-N-based the electrochemical detection of small organic antigens in the health care area.
Correlation between occupational exposure levels to toluene and urinary hippuric acid (HA) concentrations were studied for 124 workers at 54 work places. The highest indoor toluene concentration measured at printing process was 81.116 ppm, and their geometric average concentration was as high as 12.304 ppm. The geometric average concentration of hippuric acid in urine samples from workers who are exposed to toluene was 0.714 g/g creatinine. This is almost five times higher than the average HA concentration from non-exposure workers. Printing workers showed the average HA concentration of 1.145 g/g creatinine from their urine samples. It is the highest concentration among the workers exposed to toluene. The correlation coefficient between HA concentrations in urine and indoor toluene concentration at work places was relatively high as r=0.624 (P<0.01). But the correlations of HA with sex, smoking, drinking, age and employment history was relatively low. We can express the regression equation for the urinary HA concentration which is Y = 0.037X + 0.562 as exposure toluene concentration is X. The urinary HA concentrations showed significantly increase depend on indoor toluene concentration at work place.
Objectives: In this study, we summarized the External Quality Assessment Scheme (EQAS) for the biological monitoring of occupational exposure to toxic chemicals which started in 1995 and continued until a $31^{st}$ round robin in the spring of 2010. The program was performed twice per year until 2009, and this was changed to once a year since 2010. The objective of the program is to ensure the reliability of the data related to biological monitoring from analytical laboratories. Methods: One hundred and eighteen laboratories participated in the $31^{st}$ round robin. The program offers 5 items for inorganic analysis: lead in blood, cadmium in blood, manganese in blood, cadmium in urine, and mercury in urine. It also offers 10 items for organic analysis, including hippuric acid, methylhippuric acid, mandelic acid, phenylglyoxylic acid, N-methylformamide, N-methylacetamide, trichloroacetic acid, total trichloro-compounds, trans,trans-muconic acid, and 2,5-hexanedione in urine. Target values were determined by statistical analysis using consensus values. All the data, such as chromatograms and calibration curves, were reviewed by the committee. Results: The proficiency rate was below 70% prior to the first round robin and improved to over 90% for common items, such as PbB and HA, while those for other items still remained in the range of 60-90% and need to be improved up to 90%. Conclusion: The EQAS has taken a primary role in improving the reliability of analytical data. A total quality assurance scheme is suggested, including the validation of technical documentation for the whole analytical procedure.
Toluene, xylene and styrene are volatile organic solvents that are commonly used in mixtures in many industries. Because these solvents are metabolized and then excreted in urine, their urinary metabolites are thought to be biomarkers of occupational exposure to these solvents. Therefore, a simple, rapid, and yet reliable analytical method for determining the metabolites is required for accurate biological monitoring. In the present study, a simple and rapid HPLC-UV method was developed for the simultaneous determination of eight major metabolites of toluene, xylene and styrene: hippuric acid (HA), mandelic acid (MA), o-, m- and p-methylhippuric acids (o-, m- and p-MHAs), and o-, m- and p-cresols. A monolithic column was employed as the stationary phase and several conditions, including flow rate, composition of mobile phase and column temperature, were variables for the optimization of the chromatographic resolution. All eight metabolites were successfully resolved within 5 minutes in 10% aqueous ethanol containing 0.3% acetic acid and 1.6% $\beta$-cyclodextrin, using a flow rate gradient of 1.0 - 5.0 mL/min at 25 ${^{\circ}C}$. The performance of this method was validated by linearity, intra- and inter-day accuracy, and precision. The linearity was observed with correlation coefficients of 0.9998 for HA, 0.9999 for MA, 0.9989 for o-MHA, 0.9998 for m-MHA, 0.9991 for p-MHA, 0.9997 for o-cresol, 0.9998 for m-cresol, and 0.9986 for p-cresol. The intra- and inter-day precision of the method were less than 5.89% (CV) and the accuracy ranged from 92.95 to 106.62%. The validity was further confirmed by analysis of reference samples that were prepared by the inter-laboratory quality assurance program of the Korea Occupational Safety and Health Agency (KOSHA, Seoul, Korea). All measured concentrations of the analytes agreed with the certified values.
Kim, Jung-Hyun;Kim, Dae-Seon;Park, Jae-Sung;Kang, Tack-Shin
Proceedings of the Korean Environmental Health Society Conference
/
2003.06a
/
pp.187-191
/
2003
In this study, biomonitoring methods were developed to measure BTEXs exposure level in the air, metabolites of benzene and toluene in human urine, individual susceptibility markers in human blood for evaluation of the health effects about environmental pollution. We have also performed a small-scaled molecular epidemiology study on residents in Chuncheon and workers in workplace for these method applications. The workers in workplace were surveyed as study areas, and the residents in Chuncheon which is in the suburban area were surveyed as comparative areas in this study. Actually, 31 workers in as target group and 33 residences in as control group this epidemiological study. The results obtained from this study were as follows: 1. Benzene is a well-known carcinogen, it's median concentrations were 0.00024∼0.02057ppm at suburban area and 0.002∼00.654ppm at work place, These benzene concentrations were not exceed the OSHA(Occupational Safety and Health Administration) threshold benzene level of 1ppm in the states. 2. Metabolites product of benzene(t,t-Muconic Acid) and toluene(Hippuric Acid) were not significant both in suburban and workplace area. The median concentration of t,t-MA and HA were 0.0122, 1.44277g/g creatinine, respectively. 3. In the case of individual susceptibility markers as CYPlAl, 41.8% of them has homozygous wild type(W) and who has heterozygous variant type(H) was 35.4% and 22.8% of homozygous variant type(M) genetic type. In the case of CYP2E1, 62.82% of them has homozygous wild type(D) type, 34.62% of each has heterozygous variant type (DC) and 2.56% of them has homozygous variant type (CC). Who doesn't have GSTM1 gene was 46.25% and who has GSTM1 gene was 53.75%. Who doesn't have GSTT1 gene was 40.0% in study groups and who has GSTT1 gene was 60.0%. Who has W genetic type, which is homozygous wild type of GSTP1, was 69.18% and H genetic type, which is heterozygous variant type was 28.4%. M genetic type which is homozygous variant type was 2.4%. 4. Concentration differences of metabolites such as t,t-MA and HA in urine, which is generated by individual susceptibility marker of GSTM1, GSTT1, GSTP1 gene of Phase I and CYP1A1, CYP2E1 gene of Phase II, was examined. As a result, GSTP1 and GSTM1 indicate slight differences depend on the amount of metabolites in urine, it was not statistically significant.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.