• Title/Summary/Keyword: High-volume

Search Result 6,458, Processing Time 0.033 seconds

High-pressure synchrotron X-ray diffraction study of tremolite and actinolite in various fluids

  • Kong, Mihye;Vogt, Thomas;Lee, Yongjae
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1218-1224
    • /
    • 2018
  • Pressure-dependent structural and morphological changes of two amphibole minerals, tremolite and actinolite, were investigated up to 7.0 GPa using synchrotron X-ray powder diffraction underthree different pressure transmission media (PTM): water (W), $CO_2$ and silicone oil (SI). The elastic response of tremolite and actinolite are found to be dependent on the PTM used. When using water (W) as PTM, tremolite and actinolite show normal volume contractions with bulk moduli of 74(1) and 78(1) GPa, respectively. When using $CO_2$ as PTM, we observe the formation of calcite from tremolite above 3.8(1) GPa, whereas actinolite did not show any carbonation reaction. Under silicone oil PTM, we observe modulated volume contraction behaviors in both samples, compared to water and $CO_2$ PTM, with bulk moduli in the order of 90(1) and 94(4) GPa for tremolite and actinolite, respectively.

Esophageal Cancer in Korea: Epidemiology and Treatment Patterns

  • Park, Seong Yong;Kim, Dae Joon
    • Journal of Chest Surgery
    • /
    • v.54 no.6
    • /
    • pp.454-459
    • /
    • 2021
  • According to statistics from 2017, esophageal cancer is the fifteenth most common cancer and the eleventh most common cause of cancer-related death in Korea. The most common pathology is esophageal squamous cell carcinoma. Moreover, the incidence of esophageal cancer has been gradually decreasing in Korea, and the percentage of early-stage cases has gradually increased to the point that it is higher than that of other countries. The 5-year relative survival rate has improved over time. Approximately 800 esophagectomy procedures are performed annually. Using a cut-off number of 21 cases per 2 years to define high-volume centers, it was found that 70% of esophagectomies were performed by a few high-volume centers. Unfortunately, there is no nationwide registry or database on esophageal cancer and esophagectomy in Korea. Efforts to establish a nationwide database on esophageal cancer and esophagectomy should be made.

Dense Plasma Sources for Conventional and $PI_3$ Implanters

  • S.A. Nikiforov;Lee, H.S.;Kim, G.H.;G.H. Rim
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.29-39
    • /
    • 1999
  • Both conventional and PI3 implanters require dense sources for high productivity rate, and small sheath expansion in PI3 besides. The problem of the creation of large volume uniform plasma in PI3 facilities replaces that of beam forming in accelerators. Some aspects of ion extraction in both cases and Langmuir probe plasma diagnostics with be discussed. Plasma parameters of large volume multicusp dc hot cathode and inductively coupled RF plasma sources obtained with Langmuir probe and ion mass analyzer with be presented. Design features and performances of high current Freeman and ECR ion sources will be described.

  • PDF

Development of the Soil Bioengineering Techniques for Restoring of Degraded Forest Area (V) - Pull-out Resistance Characteristics of Shrubs' roots - (산림훼손지복원을 위한 Soil Bioengineering 기술개발(V) - 관목류의 뿌리인발저항 특성 -)

  • Cha, Du-Song;Oh, Jae-Heun;Ji, Byoung-Yun;Cho, Koo-Hyun;Lee, Hae-Joo
    • Journal of Forest and Environmental Science
    • /
    • v.24 no.2
    • /
    • pp.111-118
    • /
    • 2008
  • Pull-out resistance tests of root were carried out for 7 shrub species which are mainly used greening of deteriorated forest slope. Mean pull-out resistance forces of Aralia elata, Salix koreensis and Stephanandra incisa were 37.26 kgf, 34.56 kgf and 26.00 kgf, respectively. The pull-out resistances were high as collar diameter and volume of the root increased. Correlations between root collar diameter and root volume were high in Rubus crataegifolius, but on the other hand, the correlation was lowest in Zanthoxylum schinifolium. There were significant differences in pull-out resistance by root collar diameters, and the difference of pull-out resistance by species showed only below 20 ml root volume.

  • PDF

Evaluation of Green House Gases by Transportation Using Traffic Census Results from Changwon City (창원시 실제 교통량 자료를 이용한 도로수송부문 온실가스 배출량 평가)

  • Oh, Il-Hwan;Lee, Seung-Hoon;Cheong, Jang-Pyo;Kim, Tae-Hyeung;Seo, Jeoung-Yoon
    • Journal of Environmental Science International
    • /
    • v.18 no.7
    • /
    • pp.747-754
    • /
    • 2009
  • In this study, which aims to estimate the volume of greenhouse gas emitted by road transportation vehicles in Changwon City, the emission rate was calculated on the basis of the actual traffic volume measured at major crossroads and compared with the results obtained from the methodology used to estimate the greenhouse gas emissions of road transportation provided in the IPCC 2006 GL guidelines (Tier 1, Tier 3). Analysis of the results of the comparison showed that the Tier 1 methodology, which was applied in the estimation of the rate of greenhouse gas emissions, carries a high probability of underestimation, while the Tier 3 methodology carries a relatively high probability of overestimation. Therefore, when considering the assignment of permissible rates of emission to local governments, the application of the methodology, i.e. whether one uses Tier 1 or Tier 3, may result in a large difference in the rate of allowable emissions. It is suggested that a method based on the actual volume of traffic would be the most reasonable one with regard to the development of a realistic plan.

Experimental Study to Examine Wear Characteristics and Determine the Wear Coefficient of Ductile Cast Iron (DCI) Roll (Ductile Cast Iron (DCI) 롤의 마모 특성 고찰 및 마모계수 도출을 위한 실험적 연구)

  • Byon, Sang-Min
    • Tribology and Lubricants
    • /
    • v.33 no.3
    • /
    • pp.98-105
    • /
    • 2017
  • A pin-on-disk test is performed to measure the wear volume of a ductile cast iron (DCI) roll when it wears down using a high carbon steel and two alloy steels at different sliding velocities between the roll and the material (steel). Normal pressure is set as constant and test temperatures are 400, 500 and $600^{\circ}C$. In addition, thermal softening behavior of the DCI roll is examined using a high-temperature micro-hardness tester and the surface hardness variation of the DCI roll is expressed in terms of temperature and heating time. Based on experimental data, a wear coefficient used in Archard's wear model for each material is obtained. The wear volume is clearly observed when the test temperature is $400^{\circ}C$ and sliding velocity varies. However, it is not measured at temperatures of $500^{\circ}C$ and $600^{\circ}C$ even with variations in sliding velocity. From the optical photographs of the pin and disk, the abrasive wear is observed at $400^{\circ}C$ clearly, but no at $500^{\circ}C$ and $600^{\circ}C$. At higher temperatures, the pin surface is not smooth and has many tiny caves distributed on it. It is found that wear volume is dependent on the carbon contents rather than alloy contents. Results also reveal that the variations of wear coefficients are almost linearly proportional to the carbon contents of the material.

Effect of Carbon and Nickel on Microstructure and Low Temperature Charpy Impact Properties of HSLA Steels (HSLA 강의 미세조직과 저온 샤르피 충격 특성에 미치는 탄소와 니켈의 영향)

  • Eom, Haewon;Cho, Sung Kyu;Cho, Young Wook;Shin, Gunchul;Kwon, Yongjai;Lee, Jung Gu;Shin, Sang Yong
    • Korean Journal of Materials Research
    • /
    • v.30 no.4
    • /
    • pp.184-196
    • /
    • 2020
  • In this study, effects of carbon and nickel on microstructure and low temperature Charpy impact properties of HSLA (high strength low alloy) steels are investigated. To understand the complex phase transformation behavior of HSLA steels with high strength and toughness before and after welding processes, three kinds of HSLA steels are fabricated by varying the carbon and nickel content. Microstructure analysis, low temperature Charpy impact test, and Vickers hardness test are performed for the base metals and CGHAZ (coarse-grain heat affected zone) specimens. The specimens with the lowest carbon and nickel content have the highest volume fraction of AF, the lowest volume fraction of GB, and the smallest GB packet size. So, the low temperature Charpy absorbed energy of the CGHAZ specimen is the highest. The specimens with increased carbon and nickel content have the lowest volume fraction of AF, the highest volume fraction of GB, and the largest GB packet size. So, the low temperature Charpy absorbed energy of the CGHAZ specimen is the lowest.

A Study on the Performance Evaluation and Revitalization of Korea Port Distripark (항만배후단지 성과평가와 활성화 연구)

  • Kim, Seung-Chul;Kang, Hyo-Won
    • Journal of Korea Port Economic Association
    • /
    • v.36 no.3
    • /
    • pp.137-154
    • /
    • 2020
  • In this study, we analyze the performance of five major port distriparks and present a development plan. The analysis groups the performance into three categories: revitalization of companies in port distriparks, contribution to the port volume, and contribution to the national economy. The key parameters examined in detail include the ratio of hinterland volume to port volume (container and total cargo), port volume growth contribution rate, and job creation. Our results indicate that Gwangyang and Ulsan Ports showed steady growth for all the indicators analyzed, while Gwangyang Port was the only one among the five ports to display consistent steady growth. The results suggest that to achieve consistent growth, high value-added and specialized port distriparks based on the local economy should be established.

Fracture Behavior of UHPC Reinforced with Hybrid Steel Fibers (하이브리드 강섬유로 보강된 UHPC의 파괴거동)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.223-234
    • /
    • 2016
  • In this study, direct tension test for hybrid steel fiber reinforced ultra-high performance concrete (UHPC) containing two different steel fibers with a length of 16 and 19 mm was performed to investigate the fracture behavior of UHPC. Test results showed that crack strength and tensile strength, and fracture energy increased with increasing the fiber volume ratio. Based on the test results, the peak cohesive stress at the crack tip, tensile strength, and fracture energy depending on the fiber volume ratio were proposed. The proposed tensile strength of UHPC was suggested as a function of the fiber volume ratio and compressive strength. The peak cohesive stress at the crack tip and fracture energy were also proposed as a function of the tensile strength. The predicted values were relatively agree well with the test results. Thus, the proposed equations is expected to be applicable to UHPC with a compressive strength of 140~170 MPa and a fiber volume ratio of less than 2%.

Analysis of High Dose Rate Intracavitary Radiotherapy(HDR-ICR) Treatment Planning for Uterine Cervical Cancer (자궁경부암의 고선량율 강내치료 선량계획 분석)

  • Chai, Gyu-Young
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.387-392
    • /
    • 1994
  • Purpose : This study was done to confirm the reference point variation according to variation in applicator configuration in each fractioation of HDR ICR. Materials and Methods : We analyzed the treatment planning of HDRICR for 33 uterine cervical cancer patients treated in department of therapeutic radiology from January 1992 to February 1992. Analysis was done with respect to three view points-Interfractionation A point variation, interfractionation bladder and rectum dose ratio variation, interfractionation treatment volume variation. Interfractionation A point variation was defined as difference between maximum and minimum distance from fixed rectal point to A point in each patient. Interfractionation bladder and rectum dose ratio variation was defined as difference between maximum and minimum dose ratio of bladder or rectum to A point dose in each patient, Interfractionation treatment volume variation was defined as difference between miximum and minimum treatment volume which absorbed over the described dose-that is, 350 cGy or 400 cGy-in each patient. Results The mean of distance from rectum to A point was 4.44cm, and the mean of interfractionation distance variation was 1.14 cm in right side,1.09 cm in left side. The mean of bladder and rectum dose ratio was $63.8\%$ and $63.1\%$ and the mean of interfractionation variation was $14.9\%$ and $15.8\%$ respectively. With fixed planning administration of same planning to all fractionations as in first fractionation planning-mean of bladder and rectum dose ratio was $64.9\%$ and $72.3\%$.and the mean of interfraction variation was $28.1\%$ and $48.1\%$ reapectively. The mean of treatment volume was $84.15cm^3$ and the interfractionation variation was $21.47cm^2$. Conclusion : From these data, it was confirmed that there should be adapted planning for every fractionation ,and that confirmation device installed in ICR room would reduce the interfractionation variation due to more stable applicator configuration.

  • PDF