• Title/Summary/Keyword: High-resolution vessel wall imaging

Search Result 10, Processing Time 0.031 seconds

High-Resolution Magnetic Resonance Imaging of Intracranial Vertebral Artery Dissecting Aneurysm for Planning of Endovascular Treatment

  • Chun, Dong Hyun;Kim, Sung Tae;Jeong, Young Gyun;Jeong, Hae Woong
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.155-158
    • /
    • 2015
  • The equipment and techniques associated with magnetic resonance imaging (MRI) have rapidly evolved. The development of 3.0 Tesla MRI has enabled high-resolution imaging of the intracranial vessel wall. High-resolution MRI (HRMRI) can yield excellent visualization of both the arterial wall and lumen, thus facilitating the detection of the primary and secondary features of intracranial arterial dissection. In the present report, we describe the manner in which HRMRI affected our endovascular treatment planning strategy in 2 cases with unruptured intracranial vertebral artery dissection aneurysm. HRMRI provides further information about the vessel wall and the lumen of the unruptured intracranial vertebral artery dissecting aneurysm, which was treated by an endovascular approach in the 2 current cases.

Advances in Fast Vessel-Wall Magnetic Resonance Imaging Using High-Density Coil Arrays

  • Yin, Xuetong;Li, Nan;Jia, Sen;Zhang, Xiaoliang;Li, Ye
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.229-251
    • /
    • 2021
  • Arteriosclerosis is the leading cause of stroke, with a fatality rate surpassing that of ischemic heart disease. High-resolution vessel wall magnetic resonance imaging is generally recognized as a non-invasive and panoramic method for the evaluation of arterial plaque; however, this method requires improved signal-to-noise ratio and scanning speed. Recent advances in high-density head and neck coil arrays are characterized by broad coverage, multiple channels, and closefitting designs. This review analyzes fast magnetic resonance imaging from the perspective of accelerated algorithms for vessel wall imaging and demonstrates the need for effective algorithms for signal acquisition using advanced radiofrequency system. We summarize different phased-array structures under various experimental objectives and equipment conditions, introduce current research results, and propose prospective research studies in the future.

Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo (고속 내시경적 OFDI 시스템 개발과 이를 이용한 3차원 생체 혈관 내부 이미징)

  • Cho, Han Saem;Jang, Sun-Joo;Oh, Wang-Yuhl
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.67-71
    • /
    • 2014
  • Intravascular optical coherence tomography (OCT) enables imaging of the three-dimensional (3D) microstructure of a blood vessel wall. While 3D vascular visualization provides detailed information of the vessel wall and intraluminal structures, a longitudinal imaging pitch that is several times bigger than the imaging resolution of the system has limited true high-resolution 3D imaging. In this paper we demonstrate high-speed intravascular OCT in vivo, acquiring images at a rate of 350 frames per second. A 47-mm-long rabbit aorta was imaged in 3.7 seconds, after a short flush with contrast agent. The longitudinal imaging pitch was 34 micrometers, comparable to the transverse imaging resolution of the system. Three-dimensional volume rendering showed greatly enhanced visualization of tissue microstructure and stent struts, relative to what is provided by conventional intravascular imaging speeds.

Arterial Wall Imaging in Angiographically Occult Spontaneous Subarachnoid Hemorrhage : New Insight into the Usual Suspect

  • Yoon, Wonki;Kim, Jang Hun;Roh, Haewon;Kwon, Taek-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.245-254
    • /
    • 2022
  • Objective : The etiology of angiographically occult spontaneous subarachnoid hemorrhage (AOsSAH) is unclear. Three-dimensional (3D) high-resolution vessel wall magnetic resonance imaging (HVM) might be useful in detecting the hidden arterial wall angiopathy in patients with AOsSAH. We aimed to demonstrate the feasibility of HVM for detecting the arterial cause of AOsSAH. Methods : Patients, who were diagnosed with AOsSAH in the first evaluations and underwent HVM, were enrolled. Their clinical and radiologic data were retrospectively reviewed. Especially, focal enhancement of arterial wall on HVM and repetitive catheterized angiograms were precisely compared. Results : Among 251 patients with spontaneous SAH, 22 patients were diagnosed with AOsSAH in the first evaluations (8.76%). After excluding three patients who did not undergo 3D-HVM, 19 patients were enrolled and classified as convexal (n=2) or perimesencephalic (n=4), and diffuse (n=13) groups. In convexal and perimesencephalic groups, no focal enhancement on HVM and no positive findings on repetitive angiography were noted. In diffuse group, 10 patients showed focal enhancement of arterial wall on HVM (10/13, 76.9%). Repeated angiography with 3D reconstruction revealed four patients of angiographically positive causative arteriopathy and possible lesion in one case in the concordant location of intramural enhancement on 3D-HVM (5/10, 50%). Three of them were treated with endovascular stent insertion. All patients, except one, recovered with good clinical outcome (3-month modified Rankin score, 0 and 1). Conclusion : 3D-HVM was useful in detecting hidden true arteriopathy in AOsSAH. It may provide new insights into the etiologic investigation of AOsSAH by proving information about the arterial wall status.

High-Resolusion Magnetic Resonance Imaging of Carotid Atherosclerotic Plaque (경동맥 죽상경화반의 고해상도 자기공명영상)

  • Byun, Woo-Mok;Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.21 no.2
    • /
    • pp.143-150
    • /
    • 2004
  • A thromboembolic stroke is believed to be precipitated by a rupture of vulnerable atheromatous plaques. Until recently the assessment of a further risk of stroke in high-risk patients in whom atherosclerosis has presented with a transient ischaemic attack (TIA), has been confined to a quantitative assessment of the luminal patency of the internal carotid artery. These traditional stratification parameters are no longer believed to be the most accurate predictors of a thrombo-embolism. This is because the process of vessel wall remodeling can maintain a luminal patency, and consequently, quite large friable plaques may remain unidentified. Accordingly, there is a need for an improved risk assessment. The fibrous cap of a vulnerable plaque is thinner, and an intraplaque hemorrhage and inflammation can occur during the development of atherosclerotic plaque. Several imaging methods for identifying vulnerable plaques have been developed. Recently, high resolution magnetic resonance (MR) imaging has emerged as an accurate non-invasive tool that can characterize the carotid plaque components in vivo. A High resolution carotid magnetic resonance is capable of distinguishing an intact, thick fibrous cap from a thin and ruptured cap in carotid plaque. In addition, a plaque MR can identify the active inflammation and detect a hemorrhage. High resolution carotid MR imaging is a valuable noninvasive method for quantifying the plaque components and identifying vulnerable plaque.

  • PDF

In Vivo Visualization of Flow in Xylem Vessels of a Bamboo Using X-ray Micro-imaging Technique (X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측)

  • Kim, Yang-Min;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1693-1696
    • /
    • 2004
  • Synchrotron X-ray micro-imaging technique was employed to monitor non-invasively the refilling process of water inside the xylem vessels in bamboo leaves. The consecutive phase-contrast X-ray images clearly show both plant anatomy and the transport of water inside the xylem vessels. Traces of water-rise, vapor bubbles and variations of contact angle between the water front and the xylem wall were measured in real time. During the refilling process, air bubbles are removed when the rising water front halts at a vessel end for a while. Subsequently, it starts rising again at a higher velocity than the normal refilling speed. Repeated cavitation seems to deteriorate the refilling ability in xylem vessels. In dark environment, the water refilling process in xylem vessels is facilitated more effectively than in bright illuminated conditions. Finally, X-ray micro-imaging was famed to be a powerful, high resolution, real time imaging tool to investigate the water refilling process in xylem vessels.

  • PDF

High-Resolution Magnetic Resonance Imaging Findings of Reversible Cerebral Vasoconstriction Syndrome associated with Severe Anemia: A Case Report (중증 빈혈과 관련된 가역적 뇌혈관 수축 증후군의 고해상도 자기공명영상 소견: 증례 보고)

  • Yongsang Kim;Ra Gyoung Yoon;Ji Ye Lee;Jong-Moo Park
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.261-266
    • /
    • 2021
  • Ischemic stroke is one of the manifestations of reversible cerebral vasoconstriction syndrome (RCVS). Many precipitants and associated disorders of RCVS have been suggested. However, few case reports have indicated an association between anemia and RCVS. Here, we report a case of a 66-year-old female with severe iron deficiency anemia (IDA), who presented with ischemic stroke and cerebral vasoconstriction, which gradually improved with conservative treatment. High-resolution vessel wall magnetic resonance imaging findings and reversibility suggested the possibility of RCVS. In patients with RCVS and ischemic stroke, IDA should be considered. Prompt management should be delivered to prevent disease progression and recurrence.

Contrast-Enhanced High-Resolution Intracranial Vessel Wall MRI with Compressed Sensing: Comparison with Conventional T1 Volumetric Isotropic Turbo Spin Echo Acquisition Sequence

  • Chae Jung Park;Jihoon Cha;Sung Soo Ahn;Hyun Seok Choi;Young Dae Kim;Hyo Suk Nam;Ji Hoe Heo;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.21 no.12
    • /
    • pp.1334-1344
    • /
    • 2020
  • Objective: Compressed sensing (CS) has gained wide interest since it accelerates MRI acquisition. We aimed to compare the 3D post-contrast T1-weighted volumetric isotropic turbo spin echo acquisition (VISTA) with CS (VISTA-CS) and without CS (VISTA-nonCS) in intracranial vessel wall MRIs (VW-MRI). Materials and Methods: From April 2017 to July 2018, 72 patients who underwent VW-MRI, including both VISTA-CS and VISTA-nonCS, were retrospectively enrolled. Wall and lumen volumes, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured from normal and lesion sites. Two neuroradiologists independently evaluated overall image quality and degree of normal and lesion wall delineation with a four-point scale (scores ≥ 3 defined as acceptable). Results: Scan coverage was increased in VISTA-CS to cover both anterior and posterior circulations with a slightly shorter scan time compared to VISTA-nonCS (approximately 7 minutes vs. 8 minutes). Wall and lumen volumes were not significantly different with VISTA-CS or VISTA-nonCS (interclass correlation coefficient = 0.964-0.997). SNR was or trended towards significantly higher values in VISTA-CS than in VISTA-nonCS. At normal sites, CNR was not significantly different between two sequences (p = 0.907), whereas VISTA-CS provided lower CNR in lesion sites compared with VISTA-nonCS (p = 0.003). Subjective wall delineation was superior with VISTA-nonCS than with VISTA-CS (p = 0.019), although overall image quality did not differ (p = 0.297). The proportions of images with acceptable quality were not significantly different between VISTA-CS (83.3-97.8%) and VISTA-nonCS (75-100%). Conclusion: CS may be useful for intracranial VW-MRI as it allows for larger scan coverage with slightly shorter scan time without compromising image quality.

High-Resolution Intracranial Vessel Wall MRI Findings Among Different Middle Cerebral Artery Territory Infarction Types

  • So Yeon Won;Jihoon Cha;Hyun Seok Choi;Young Dae Kim;Hyo Suk Nam;Ji Hoe Heo;Seung-Koo Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.333-342
    • /
    • 2022
  • Objective: Intracranial atherosclerotic stroke occurs through various mechanisms, mainly by artery-to-artery embolism (AA) or branch occlusive disease (BOD). This study evaluated the spatial relationship between middle cerebral artery (MCA) plaques and perforating arteries among different MCA territory infarction types using vessel wall magnetic resonance imaging (VW-MRI). Materials and Methods: We retrospectively enrolled patients with acute MCA infarction who underwent VW-MRI. Thirty-four patients were divided into three groups according to infarction pattern: 1) BOD, 2) both BOD and AA (BOD-AA), and 3) AA. To determine the factors related to BOD, the BOD and BOD-AA groups were combined into one group (with striatocapsular infarction [BOD+]) and compared with the AA group. To determine the factors related to AA, the BOD-AA and AA groups were combined into another group (with cortical infarction [AA+]) and compared with the BOD group. Plaque morphology and the spatial relationship between the perforating artery orifice and plaque were evaluated both quantitatively and qualitatively. Results: The plaque margin in the BOD+ group was closer to the perforating artery orifice than that in the AA group (p = 0.011), with less enhancing plaque (p = 0.030). In the BOD group, plaques were mainly located on the dorsal (41.2%) and superior (41.2%) sides where the perforating arteries mainly arose. No patient in the AA group had overlapping plaques with perforating arteries at the cross-section where the perforator arose. Perforating arteries associated with culprit plaques were most frequently located in the middle two-thirds of the M1 segment (41.4%). The AA+ group had more stenosis (%) than the BOD group (39.73 ± 24.52 vs. 14.42 ± 20.96; p = 0.003). Conclusion: The spatial relationship between the perforating artery orifice and plaque varied among different types of MCA territory infarctions. In patients with BOD, the plaque margin was closer and blocked the perforating artery orifice, and stenosis degree and enhancement were less than those in patients with AA.

A Case Report of Pontine Infarction as an Initial Manifestation of Systemic Lupus Erythematosus: Diagnostic Clues from MRI and Digital Subtraction Angiography (전신성 홍반성 루푸스의 초기 증상으로 나타난 교뇌경색의 증례 보고: 자기공명영상 및 디지털감산 혈관조영술에서의 진단 단서)

  • Mi Sun Chung;Jun Soo Byun;Younghee Yim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1281-1286
    • /
    • 2021
  • Brainstem infarction due to vertebrobasilar insufficiency is a rare initial presentation of systemic lupus erythematosus (SLE) patients and small-vessel dissection as the direct cause of infarction has not been reported. We report the case of a 20-year-old female with acute infarction on the right side of the pons due to a small artery (pontine perforator) dissection, identified on digital subtraction angiography and high-resolution vessel wall MRI (vwMRI). She was diagnosed with SLE based on the presence of neurologic disorders and relevant laboratory findings. The pontine perforator-dissecting aneurysm had occluded and the right distal vertebral artery had resolved on subsequent vwMRI. She had a modified Rankin Scale (mRS) score of 1 at discharge with mild symptom improvement, and exhibited no further aggravation of symptoms at 3 or 12 months, maintaining an mRS score of 1.