• 제목/요약/키워드: High-efficient power

검색결과 1,342건 처리시간 0.029초

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev Oleg;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.89-92
    • /
    • 2001
  • Silent gas discharge method has been widely applied for ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low-cost power supply for such systems is a task of great impotency. This paper introduces high-frequency inverter type mode power supply designed for ozone generation tube and ultraviolet generation excimer lamp and considerations on this inverter and pulse density modulation control strategy applied in it.

  • PDF

Energy Scavenging 시스템을 위한 회로의 특성 (Circuit Component Requirements for Energy Scavenging System)

  • 강성묵;박경진;김호성
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1790-1795
    • /
    • 2008
  • Energy scavenging is a technique that converts ambient energy, for example, vibration and light, to electrical energy in order to supply power to low power electronic devices such as ubiquitous sensors. In this paper, we propose an optimal operation condition of power delivery circuit and design strategy for energy scavenging system in which the generated power is order of microwatt and, consequently, efficient handling of power is critical. We also propose that high data transmission rate is more realistic optimal design objective rather than high energy efficiency. It is shown that disconnection of load from the storage capacitor right after data transmission reduces energy wasting and that optimal value of storage capacitor can be determined at this condition. The feasibility of our propose is proved by experiments and we believe that the proposed design strategy will promote the application of piezoelectric micropower generator to the ubiquitous sensor networks.

An Efficient MPEG-4 Video Codec using Low-power Architectural Engines

  • Bontae Koo;Park, Juhyun;Park, Seongmo;Kim, Seongmin;Nakwoong Eum
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1308-1311
    • /
    • 2002
  • We present a low-power MPEG-4 video codec chip capable of delivering high-quality video data in wireless multimedia applications. The discussion will focus on the architectural design techniques for implementing a high-performance video compression/decompression chip at low power architectures. The proposed MPEG-4 video codec can perform 30 frames/s of QCIF or 7.5 frame/s of CIF at 27MHz for 128k∼144kbps. By introducing the efficiently optimized Frame Memory Interface architecture, low power motion estimation and embedded ARM microprocessor and AMBA interface, the proposed MPEG-4 video codec has low power consumption for wireless multimedia applications such as IMT-2000.

  • PDF

자가 충전 모듈을 이용한 USN 센서노드용 고효율 에너지 전력관리 시스템 구현 및 검증 (Design and Implementation on High Efficient EPMS(Energy-Power Management System) for USN Sensor Node Using Self-Charging Module)

  • 김현웅;박희정;임세미;오종화;노형환;박준석
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.124-130
    • /
    • 2011
  • In this paper, We design and implementation of Self-Charging Module for charging to battery which obtaining the environment inergy such as solar energy. The power chared battery through the charging module send to sensor node. And implementation of System Activation Module(SAM) based on ID system and Dynamic Power Management Module(DPM) with SPO(Self Power Off). This system consume power only communication between the sensor nodes. We verification this system by implementing the high efficiency poweer management system.

루프디자인에 따른 배관시스템의 열응력에 관한 연구 (A Study on Thermal Stress of Power Piping due to Loop Design)

  • 이정현;박지성
    • 한국생산제조학회지
    • /
    • 제23권5호
    • /
    • pp.450-455
    • /
    • 2014
  • Domestic power plants have consistently been developed over the years in industrially developed nations with high standards of living. Considering the power plant development strategy, design efficiency is of upmost importance. Therefore, an improper design directly affects the power plant's risk management plan and the potential risks of the piping system. Therefore, in this study, research is intended to be carried out to allow efficient power plant operation, through optimization of the design of the piping system. The purpose of the study is to confirm economic feasibility by changing the piping loop design, expanding the length of pipe loops, and to investigate the thermal stress influence on the piping system through simulations of systems similar in condition to those currently used in existing plants in Korea.

전력용 통신설비 신뢰도 산출 기법 연구 (A Study on the Reliability Evaluation Methodology of Power Telecommunication Facilities)

  • 이원태;김관호;김요희;이범석;우희곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.470-472
    • /
    • 1993
  • Nowadays, according to gradual progress of the information oriented society, it is being increase rapidly that social requirement for the high quality and stability of electric power supply. Therefore, for the sake of expansion of the various power system and reasonable operation and administration, there are some growing need for telecommunication system that will operate in high dependability performance and expansion by much. But beause of unestablished reliability analysis and evaluation methodology for power telecommunication system, it could not have a reasonable planning for the purpose of improving dependability performance on telecommunication system. The object of this study is to construct reasonable methodology of reliability evaluation fur the efficient power telecommunication facility administration.

  • PDF

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

나전선(裸電線)의 저손실화 설계 (Design of the Bare Electric Wire for Low Loss)

  • 정연호;이형권;손홍관;조연규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.101-103
    • /
    • 1998
  • New transmission lines are gradually constructed with high voltage and power for increase of electric power demands. And electric losses that are produced in line are increased. we made the algorithm for low loss wire and developed the computer program that makes loss of electric wire to be decreased for efficient power transmission. Electric wire is designed not to be decreased electrical and mechanical properties than that of existing electric wire.

  • PDF

Highly Efficient AC-DC Converter for Small Wind Power Generators

  • Ryu, Hyung-Min
    • Journal of Power Electronics
    • /
    • 제11권2호
    • /
    • pp.188-193
    • /
    • 2011
  • A highly efficient AC-DC converter for small wind power generation systems using a brushless DC generator (BLDCG) is presented in this paper. The market standard AC-DC converter for a BLDCG consists of a three-phase diode rectifier and a boost DC-DC converter, which has an IGBT and a fast recovery diode (FRD). This kind of two-stage solution basically suffers from a large amount of conduction loss and the efficiency greatly decreases under a light load, or at a low current, because of the switching devices with a P-N junction. In order to overcome this low efficiency, especially at a low current, a three-phase bridgcless converter consisting of three upper side FRDs and three lower side Super Junction FETs is presented. In the overall operating speed region, including the cut-in speed, the efficiency of the proposed converter is improved by up to 99%. Such a remarkable result is validated and compared with conventional solutions by calculating the power loss based on I-V curves and the switching loss data of the adopted commercial switches and the current waveforms obtained through PSIM simulations.

듀얼 모드 위상 시프트 ZVS PWM 제어 고주파 공진형 인버터를 이용한 IH 온수기 (Induction Heating Water Heater using Dual Mode Phase Shifted ZVS-PWM High Frequency Resonant Inverter)

  • 정상석;유의정;우경일;박한석
    • 전기학회논문지P
    • /
    • 제67권2호
    • /
    • pp.82-89
    • /
    • 2018
  • This paper presents a novel prototype of dual mode control based phase shift ZVS PWM high frequency load resonant inverter with lossless snubber capacitors in addition to a single active auxiliary resonant snubber for electromagnetic induction heating(IH) foam metal based consumer fluid dual packs(DPA) heater. The operating principle in steady state and unique features of this voltage source soft switching high frequency inverter circuit topology are described in this paper. The lossless snubber and auxiliary active resonant snubber assisted constant frequency phase shift ZVS PWM high frequency load resonant inverter employing IGBT power modules actually is capable of achieving zero voltage soft commutation over a widely specified power regulation range from full power to low power. The steady state operating performances of this dual mode phase shift PWM series load resonant high frequency inverter are evaluated and discussed on the basis of simulation and experimental results for induction heated foam metal heater which is designed for compact and high efficient moving fluid heating appliance in the consumer pipeline systems.