• 제목/요약/키워드: High-efficiency operation

검색결과 1,924건 처리시간 0.032초

무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구 (A Study on Installation of Monitoring System of Wireless Power Transmission System)

  • 송영상;한운기;정진수;임현성;조성구
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

새로운 DCM-ZVS DC-DC 컨버터에 관한 연구 (A Study on New DCM-ZVS DC-DC Converter)

  • 곽동걸;심재선
    • 전기전자학회논문지
    • /
    • 제16권2호
    • /
    • pp.131-137
    • /
    • 2012
  • 본 논문에서는 영전압 스위칭(ZVS)과 전류불연속 모드(DCM)에 의한 새로운 고효율의 DC-DC 컨버터에 대해 연구된다. 일반적으로 고효율의 컨버터를 만들기 위해서는 전력변환기내에 사용된 반도체 스위칭 소자의 손실을 최소화하여 이루어진다. 제안한 컨버터는 DCM에 의하여 스위치의 턴-온 동작을 영전류 스위칭(ZCS)으로 만들고, 또한 새로운 유사공진 회로를 접목하여 컨버터의 고효율을 실현시킨다. 제안한 컨버터에 사용된 제어용 스위칭 소자들은 유사공진 기법에 의해 소프트 스위칭, 즉 ZVS와 ZCS으로 동작시키고, 이에 따른 제어용 스위칭 소자들은 전압과 전류의 스트레스 없이 동작한다. 그 결과 제안한 컨버터는 스위칭 손실의 저감에 의해 고효율로 구동된다. 제안한 DCM-ZVS 컨버터의 소프트 스위칭 동작과 시스템 효율은 디지털 시뮬레이션과 실험결과를 통해 그 타당성이 입증된다.

High Efficiency High-Step-up Single-ended DC-DC Converter with Small Output Voltage Ripple

  • Kim, Do-Hyun;Kim, Hyun-Woo;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1468-1479
    • /
    • 2015
  • Renewable energy resources such as wind and photovoltaic power generation systems demand a high step-up DC-DC converters to convert the low voltage to commercial grid voltage. However, the high step-up converter using a transformer has limitations of high voltage stresses of switches and diodes when the transformer winding ratio increases. Accordingly, conventional studies have been applied to series-connect multioutput converters such as forward-flyback and switched-capacitor flyback to reduce the transformer winding ratio. This paper proposes new single-ended converter topologies of an isolation type and a non-isolation type to improve power efficiency, cost-effectiveness, and output ripple. The first proposal is an isolation-type charge-pump switched-capacitor flyback converter that includes an extreme-ratio isolation switched-capacitor cell with a chargepump circuit. It reduces the transformer winding number and the output ripple, and further improves power efficiency without any cost increase. The next proposal is a non-isolation charge-pump switched-capacitor-flyback tapped-inductor boost converter, which adds a charge-pump-connected flyback circuit to the conventional switched-capacitor boost converter to improve the power efficiency and to reduce the efficiency degradation from the input variation. In this paper, the operation principle of the proposed scheme is presented with the experimental results of the 100 W DC-DC converter for verification.

고밀도 도시철도 운행품질 개선 방안 연구 (On the Service Improvement of High-Density Urban Railway Transportation)

  • 김동희
    • 대한안전경영과학회지
    • /
    • 제12권3호
    • /
    • pp.163-168
    • /
    • 2010
  • Recently, there are many problems of service qualities such as regular-rapid-safe -comfortable transport, that was traditionally advantages in urban railway transportations. These problems cause train delays that affects consecutive schedule, capacity, operation plans, and it is hard to prevent the propagation of delay and find the recovery solution. Because the urban transport demands is continuously increased and the railway service is also expanded, the railway operation company makes efforts to improve operation performance and efficiency for passengers. In this paper, we analyse the issues and problems existing in the major operation line of high-density urban railways, and suggest the development direction of intelligent operation technology to improve the urban railway service by minimizing the occurrence and propagation of delay. And the result of numerical case study is also presented.

Efficiency Analysis of Switched Reluctance Generator According to Current Shape under Rated Speed

  • Yu, Siyang;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권4호
    • /
    • pp.491-497
    • /
    • 2013
  • This paper introduces the high efficiency operation of switched reluctance generator (SRG). The proposed SRG operates under the rated speed. The high efficiency can be obtained by the optimal current shape which can make the total losses minimum. For this purpose, theoretical analysis of the copper and core loss is done. In addition, a modified angle position control (MAPC) method which can get the optimal current shape over wide speed condition is presented. In order to verity the theory, the experimental platform is set up. The feasibility of the theory is verified by the simulation and experimental results. The proposed method is simple, reliable and easy to achieve.

초고층 공사 리프트의 그룹제어 시스템 적용을 위한 기초 연구 (A Preliminary Study to Apply Group Control System to Lifts for High-rise Construction)

  • 김태훈;임현수;김창원;김승우;조훈희;강경인
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.260-261
    • /
    • 2017
  • The objective of this study is to propose the basic design plan of system by comparing and analyzing application environment of lift and elevator group control system, as preliminary study for the application of group control system to lifts for high-rise construction. The basic design plan is suggested in terms of group control algorithm, hall call system type, operation information recording device, information communication method, and operation method. The results of this study can be used as basic data for software and hardware design for application of group control technology of lifts for super tall building construction and ultimately contribute to improve the operation efficiency of lift for high-rise construction.

  • PDF

전기자동차용 1MHz LDC에 적합한 새로운 2단계 전력변환기 (A Novel Two-Stage Power Converter suitable for 1MHz-LDC of Electric Vehicles.)

  • Tuan, Tran Manh;Choi, Woojin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.51-53
    • /
    • 2018
  • The Low Voltage DC-DC converters (LDCs) of the Electric Vehicles require high power density and high efficiency operation over the wide range of load and input voltage variations. This paper introduces a novel topology which combines three 1 MHz Half-Bridge (HB) LLC resonant converters and an Inverting Buck-Boost (IBB) converter to adjust the output voltage without frequency modulation. The switching frequency of the proposed converter is fixed at 1MHz to achieve a constant frequency operation for the resonant converter. In the proposed topology GaN FETs and planar transformers are employed to optimize the converter operation at high frequency. A 1 MHz/1.8 kW prototype converter is built to verify the feasibility and the validity of the proposed LDC topology.

  • PDF

유도가열용 ZCS PWM SEPP 고주파 인버터의 특성 (Character of Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;김칠용;곽동걸;김춘삼
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

새로운 유도가열용 소프트 스위칭 고주파 인버터 (Soft Switching High Frequency Inverter for New Induction Heating)

  • 김칠용;문상필;김영문;김해재;류재엽;김수욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

유도가열용 ZCS PWM SEPP 고주파 인버터 (Induction Heating ZCS PWM SEPP High Frequency Inverter)

  • 문상필;권순걸;이종걸;주석민;강신출
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF