• 제목/요약/키워드: High-Permeability Substrate

검색결과 41건 처리시간 0.026초

Miniaturized Broadband ENG ZOR Antenna Using a High Permeability Substrate

  • Ko, Seung-Tae;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.201-206
    • /
    • 2011
  • This paper presents a miniaturized epsilon negative (ENG) zeroth-order resonance (ZOR) patch antenna with an improved bandwidth. The miniaturization and the broad bandwidth of the ENG ZOR patch antenna are achieved by using a meandered via and a high permeability substrate instead of a straight via and a dielectric substrate. The use of a meandered via allows miniaturization of the ENG ZOR patch antenna without narrowing the bandwidth. The use of a high permeability substrate allows further miniaturization of the ENG ZOR patch antenna and improvement of the bandwidth. A high permeability substrate consisting of a multi-layered substrate is designed to have a small material loss. The antenna (kr=0.32) has a 10 dB fractional bandwidth of ~1 %, which is 1.74 times as broad as that of an antenna with a dielectric substrate.

고투자율 자성기판을 이용한 광대역 안테나 격리도 특성 개선 (Isolation Improvement of a Broadband Antenna Using a High-Permeability Substrate)

  • 허준;계영철;추호성
    • 한국전자파학회논문지
    • /
    • 제26권1호
    • /
    • pp.24-29
    • /
    • 2015
  • 본 논문에서는 고투자율 자성기판을 이용한 광대역 안테나 격리도 특성 개선방법을 제안하였다. 제안된 안테나는 평판형 모노폴 안테나의 근접 자계 분석을 바탕으로 고투자율 자성기판을 안테나에 삽입한 형상이며, 동작주파수에서의 안테나 성능을 유지하고, 차단 주파수에서의 간섭을 최소화하여 근접한 안테나와의 격리도 특성을 개선한다. 격리도 개선을 확인하기 위해 동작주파수 2 GHz인 기준 모노폴 안테나를 설정하여 제안된 안테나와 기준 안테나의 $S_{21}$을 자성기판 삽입 전후로 측정하였다. 그 결과, 기존 안테나의 동작 성능은 유지하며, 2 GHz 이상의 차단 주파수에서 $S_{21}$이 5~10 dB 이상 개선되었으며, 고투자율 자성기판을 이용하여 안테나의 격리도 특성 개선이 가능함을 확인하였다.

탈질 조건에서 투과매질 내 미생물 성장에 관한 연구

  • 최영화;오재일;배범한
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.366-369
    • /
    • 2002
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Most biobarrier studies were conducted under aerobic condition, however there were several obstacles to make aerobic condition. Thus, In this study, we examined biobarrier formation under denitrifying condition by using nitrate as an electron acceptor. Experiments were performed with a sand column inoculated with activated sludge from the nearby WWTP. The substrate medium was pumped to the sand column in an upflow mode. During the low substrate loading rate period, the extent of reduction rate in hydraulic conductivity was found similar throughout the column, and permeability became relatively stable after couple of days. However, during the high substrate loading rate period, the column demonstrated a gradient of permeability reduction, with the greatest reduction in sections nearest the column inlet. Rapid growth of microorganisms near the column inlet resulted in the unbalanced reduction of hydraulic conductivity throughout the sand column. As a result, at this denitrifying condition the thickness of biobarrier could be controlled by adjusting the medium conditions of microbial growth.

  • PDF

DC 마그네트론 스퍼터로 증착한 flexible OLED용 IZO 박막의 기계적 특성과 투습특성에 미치는 반응성 가스 첨가의 효과 (Effects of Reactive Gas Addition on the Mechanical Property and Water Permeability of IZO Films Deposited by DC Sputtering for Application to Flexible OLED)

  • 천고은;이동엽;조영래;송풍근
    • 한국표면공학회지
    • /
    • 제40권6호
    • /
    • pp.245-249
    • /
    • 2007
  • Amorphous IZO films were deposited on PET substrate by DC magnetron sputtering without substrate heating. In order to investigate effect of reactive gas addition on film properties, 0.2-0.4% of $H_2$ or $O_2$ gas was introduced during the deposition. Deposited IZO films were evaluated with mechanical property, electrical property, and water permeability. In the case of $H_2$ gas addition, mechanical property showed clear degradation compared to $O_2$ gas. In the case of $O_2$ gas, water permeability of the IZO film was increased compared to $H_2$ gas which could be attributed to the low adhesion of the film caused by bombardment of high energy negative oxygen ion. As a result, it is confirmed that water permeability of the film could be strongly affected by adhesion of the film.

플라즈마 종합에 의해 제조된 복합막에 대한 $O_{2}/N_{2}$의 기체투과 특성 (The Permeation Characteristics of $O_{2}/N_{2}$ Gas for Composite Membrane Prepared by Plasma Polymerization)

  • 현상원;정일현
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.147-155
    • /
    • 1998
  • In this study, we prepared non-porous plasma membrane for having high permeability and selectivity and this membrane was deposited on the $Al_{2}O_{3}$ membrane by using $CHF_{3}$ & $SiH_{4}$ monomer. Also, we investigated for the permeation characteristics of the plasma polymer membrane by Ar plasma treatment. When the position of substrate was near cathode, the selectivity was increased with Ar plasma treatment time and rf-power. The pore size of $Al_{2}O_{3}$ membrane had an effect on the permeability and the position of substrate affected selectivity.

  • PDF

Comparison of Gastrointestinal Permeability of Caffeine, Propranolol, Atenolol, Ofloxacin, and Quinidine Measured Using Ussing Chamber System and Caco-2 Cell Monolayer

  • Song, Im-Sook;Choi, Young A;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • 제8권2호
    • /
    • pp.34-38
    • /
    • 2017
  • The purpose of this study was to develop a cocktail approach for the measurement of the permeability of marker compounds, caffeine and propranolol (high permeability), ofloxacin (intermediate), atenolol (low), and quinidine (P-glycoprotein substrate), simultaneously. Then we compared the permeability in Caco-2 cells with that in rat intestinal segments. The difference between individual measurement and cocktail approach was less than 20 %, and the permeabilities of these compounds were similar to those previously reported, suggesting that the cocktail transport study and simultaneous drug analysis were successfully developed and validated in this study. Additionally, in the application of this cocktail method, the permeability of five drugs in rat jejunum was similar to that in ileum but different from that in colon, which was measured using the Ussing chamber system. Moreover, permeability in jejunum and ileum was similar to that in Caco-2 cells. In conclusion, the permeability in Caco-2 cells was equivalent to the permeability in rat jejunum and ileum determined with the Ussing system. Therefore, this newly developed cocktail assay and its application to the Ussing system can be a useful tool for robust and rapid screening for site-specific permeability in rat intestine, thus accelerating the prediction of absorption of new chemical entities.

연자성 박막 제지의 형성 및 특성 (Fabrication and characteristics of soft magnets on paper)

  • 김용성;신경호;김광호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.96-99
    • /
    • 2001
  • The formation of soft magnets on paper(SMOP) is proposed for the first time and we have demonstrated it successfully. Iorn was used to form the soft magnet thin film on paper. And Cr layer was used as a buffer layer because the roughness of substrate(paper) is not negligible. The maximum magnetization of Cr/Fe/Cr/Paper(Fe:5000${\AA}$) is about 1000 [emu/cc] and the coercive field is about 80 [Oe.]. It is necessary to reduce the coercivity and to enlarge the magnetization value of SMOP to perform a good soft magnetic characteristics on paper. On, the permalloy material is the proper candidate for its high permeability, low coercivity and high magnetization values.

  • PDF

SOFC 음극의 기공구조가 음극특성에 미치는 영향 (Effect of the Pore Structure on the Anodic Property of SOFC)

  • 허장원;이동석;이종호;김재동;김주선;이해원;문주호
    • 한국세라믹학회지
    • /
    • 제39권1호
    • /
    • pp.86-91
    • /
    • 2002
  • 고체 산화물 연료전지(Solid Oxide Fuel Cell; SOFC)는 무공해 청정에너지원으로서 기존의 발전방식을 대체할 차세대 에너지원으로 각광받고 있다. 고체산화물 연료전지의 구성요소는 크게 음극(anode), 양극(cathode), 전해질(electolyte)로 나뉘어 지는데 그 중 음극은 전극으로서의 역할은 물론 음극지지형인 경우 지지체 역할가지 수행해야 하기 때문에 아주 다양한 특성이 요구되어지고 있다. 그 중에서도 연료전지 성능의 최대 감쇄요인으로 지적되고 있는 분극저항을 줄이기 위해서는 높은 전기전도도와 높은 가스투과도가 요구되고있다. 본 연구에서는 음극 제조과정 중 첨가하는 기공 전구체의 종류에 따라 기판의 기공구조가 어떻게 바뀌는지 또 그로 인해 기판의 미세구조 및 전기전도도가 어떠한 영향을 받는지 관찰하였다. 결과 음극기판의 미세구조 및 전기전도도는 기공전구체의 종류에 따라 크게 달라졌으며 특히 이방성을 가지는 기공전구체의 사용은 전도성상의 단락 및 비효율적인 기공의 양산을 가져와 결과적으로 연료전지 성능을 악화시킬 것으로 예상된다.

Optimized Synthesis Conditions of Polyethersulfone Support Layer for Enhanced Water Flux for Thin Film Composite Membrane

  • Son, Moon;Choi, Hyeongyu;Liu, Lei;Park, Hosik;Choi, Heechul
    • Environmental Engineering Research
    • /
    • 제19권4호
    • /
    • pp.339-344
    • /
    • 2014
  • Different types of polyethersulfone (PES) support layer for a thin film composite (TFC) membrane were synthesized under various synthesis conditions using the phase inversion method to study the combined effects of substrate, adhesive, and pore former. The permeability, selectivity, pore structure, and morphology of the prepared membranes were analyzed to evaluate the membrane performance. The combined use of substrate, adhesive, and pore former produced a thinner dense top layer, with more straight finger-like pores. The pure water permeation (PWP) of the optimized PES membrane was $27.42L/m^2hr$ (LMH), whereas that of bare PES membrane was 3.24 LMH. Moreover, membrane selectivity, represented as divalent ion ($CaSO_4$) rejection, was not sacrificed under the synthesis conditions, which produced the dramatically enhanced PWP. The high permeability and selectivity of the PES membrane produced under the optimized synthesis conditions suggest that it can be utilized as a potential support layer for TFC membranes.

유지보수용 스프레이 모르타르의 부착강도 및 내구성 (Bond Strength and Durability of Spray Mortar Purposed for Repair)

  • 윤경구;김성권;이완성
    • 산업기술연구
    • /
    • 제33권A호
    • /
    • pp.101-107
    • /
    • 2013
  • The purpose of this study was to investigate bond strength between substrate and HES-LMS mortar, durability of HES-LMS mortar with latex content(0%, 5%, 10%). To measure the bond strength, the direct tensile test based on uniaxial tensile test was used, which was proposed by Kuhlman(1990). Also, Resistance for water permeability, water absorption and image analysis for air void system were conducted to estimating durability of HES-LMS mortar.

  • PDF