• 제목/요약/키워드: High-Ductility

검색결과 969건 처리시간 0.027초

연속섬유 거푸집으로 보강된 압축부재의 역학적 특성에 관한 연구 (A Study on the Mechanical Characteristics of Compression Member Confined the Cast Frame Using Continuous Fiber Mesh)

  • 고훈범
    • 한국건축시공학회지
    • /
    • 제2권4호
    • /
    • pp.99-104
    • /
    • 2002
  • Recently, the continuous fiber materials has become more important materials to repair and to reinforce concrete structural members. Continuous fiber meshes are effective for shear and confining reinforcement and provide excellent durability when combined with high strength mortar The purpose of this study is to verify the relationship between concrete strength and the ductility of inner concrete confined laterally by continuous fiber meshes. For this study, Experimental studies were conducted by compressive members using the cast frame of high strength mortar and continuous fiber meshes. Therefore, the result shows that compressive strength and ductility has improved according to the amount of the fiber meshes, and that the lateral confined effect of members with 3- or 4-axis mesh arrangement is bigger than that of members with 2-axis mesh. These data have to be used to verify the characteristic of concrete structure members reinforced continuous fiber mesh.

고인성 섬유보강 시멘트 복합체를 사용한 내진요소의 구조성능 (The Structural Behavior of Seismic Devices using High Performance Fiber Reinforced Cement Composites)

  • 양일승;윤현도;한병찬;박완신;김선우;문연준
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.21-24
    • /
    • 2004
  • Structural performance of the seismic devices made by steel bar and high performance fiber reinforced cement composites(HPFRCCs) was experimentally observed. These dampers will be applied for reducing damage as well as seismic response. The advantages of the HPFRCCs damper is selective structural performance, strength, stiffness, and ductility by changing configuration, bar arrangements and type of materials used. The experimental results indicate that elemental ductility is much increased with decreasing damage when the HPFRCCs are applied to the damper. It means cementitious damper for structural control is available which has much merit in performance and cost.

  • PDF

Application of Steel-tubed Concrete Structures in High-rise Buildings

  • Zhou, Xuhong;Liu, Jiepeng
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.161-167
    • /
    • 2019
  • Making full use of material strength, maintaining sufficient ductility of structural components, and ensuring simple and robust connections are crucial to the development of steel-concrete composite structures. The steel-tubed concrete structure uses thin-walled steel tube to provide confinement, so that the strength and ductility of the concrete core are improved. Meanwhile, the thin-walled steel tube is terminated at the beam-column joint to avoid the local buckling problem and simplify the connections between steel tube and RC members. A brief overview of the development of steel-tubed concrete structures is presented. Through the discussion on the structural behavior of steel-tubed concrete and the introduction of typical practical projects, the prospects for future research are highlighted.

HIGH BURNUP FUEL ISSUES

  • Rudling, Peter;Adamson, Ron;Cox, Brian;Garzatolli, Friedrich;Strasser, Alfred
    • Nuclear Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.1-8
    • /
    • 2008
  • One of the major current challenges to nuclear energy lies in its competitiveness. To stay competitive the industry needs to reduce maintenance and fuel cycle costs, while enhancing safety features. Extended burnup is one of the methods applied to meet these objectives However, there are a number of potential fuel failure causes related to increased burnup, as follows: l) Corrosion of zirconium alloy cladding and the water chemistry parameters that enhance corrosion; 2) Dimensional changes of zirconium alloy components, 3) Stresses that challenge zirconium alloy ductility and the effect of hydrogen (H) pickup and redistribution as it affects ductility, 4) Fuel rod internal pressure, 5) Pellet-cladding interactions (PCI) and 6) pellet-cladding mechanical interactions (PCMI). This paper discusses current and potential failure mechanisms of these failure mechanisms.

Fatigue life curves of alloy 617 in the temperature range of 800-950℃

  • Injin Sah;Jaehwan Park;Eung-Seon Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.546-554
    • /
    • 2023
  • The cyclical behavior of Alloy 617 was examined at 25 ℃ and high temperatures of 800, 850, 900, and 950 ℃ in air to obtain its fatigue life curves. The specimens tested at 25, 800, and 850 ℃ cyclically hardened, whereas those tested above 900 ℃ cyclically softened from the first cycle, that is, their fatigue life was reduced at high temperatures owing to loss of strength. Parameters of the typical Coffin-Manson-Basquin relationship were determined for each test temperature. Interestingly, no significant difference in fatigue life was observed for the specimens tested in the range of 800-950 ℃. Owing to the similarity in fatigue life, we determined fatigue strength and fatigue ductility exponents that could be applied for this temperature range. The parameters obtained were close to the universal slopes, although the fatigue ductility exponent was slightly different. The proposed fatigue life curves were compared with those presented in ASME code.

Higher-mode effects for soil-structure systems under different components of near-fault ground motions

  • Khoshnoudian, Faramarz;Ahmadi, Ehsan;Sohrabi, Sina;Kiani, Mahdi
    • Earthquakes and Structures
    • /
    • 제7권1호
    • /
    • pp.83-99
    • /
    • 2014
  • This study is devoted to estimate higher-mode effects for multi-story structures with considering soil-structure interaction subjected to decomposed parts of near-fault ground motions. The soil beneath the super-structure is simulated based on the Cone model concept. Two-dimensional structural models of 5, 15, and 25-story shear buildings are idealized by using nonlinear stick models. The ratio of base shears for the soil-MDOF structure system to those obtained from the equivalent soil-SDOF structure system is selected as an estimator to quantify the higher-mode effects. The results demonstrate that the trend of higher-mode effects is regular for pulse component and has a descending variation with respect to the pulse period, whereas an erratic pattern is obtained for high-frequency component. Moreover, the effect of pulse component on higher modes is more significant than high-frequency part for very short-period pulses and as the pulse period increases this phenomenon becomes vice-versa. SSI mechanism increases the higher-mode effects for both pulse and high-frequency components and slenderizing the super-structure amplifies such effects. Furthermore, for low story ductility ranges, increasing nonlinearity level leads to intensify the higher-mode effects; however, for high story ductility, such effects mitigates.

80 MPa의 압축강도를 갖는 콘크리트 보의 휨강도 예측 (Prediction of Bending Strength of Concrete Beams with Compressive Strength of 80 MPa)

  • 김경철;양인환;조창빈
    • 콘크리트학회논문집
    • /
    • 제29권4호
    • /
    • pp.335-343
    • /
    • 2017
  • 본 연구에서는 80 MPa 수준의 압축강도를 갖는 고강도 콘크리트 부재의 휨 강도 특성에 대한 연구를 수행하였다. 실험변수는 SD 400 및 SD 600의 철근 공칭항복강도, 0.98~1.97%의 휨 철근비 및 부재의 전단지간-유효깊이 비(a/d)를 고려하였다. 고강도 콘크리트 보의 하중-처짐 관계, 연성, 휨강도 및 현행 설계코드에 의한 휨강도 예측값을 분석하였다. 고강도 철근의 사용은 부재의 휨강도는 증가시키는 반면에 연성을 감소시킨다. 전단지간-유효깊이 비가 증가함에 따라 연성도는 감소한다. 현행 콘크리트구조기준, Erocode 2 및 도로교설계기준에 의한 휨강도 예측값과 휨강도 측정값을 비교하였다. 고강도 콘크리트 보의 휨강도 예측값은 측정값을 과소평가하고 있으며, 보수적인 설계결과를 나타낸다. 또한, 강도감소계수를 사용하는 콘크리트구조기준에 의한 고강도 콘크리트 보의 휨강도 예측값과 재료계수를 사용하는 Erocode 2 및 도로교설계기준에 의한 휨강도 예측값은 서로 유사하게 나타난다.

한정연성 철근콘크리트 교각의 유사동적 실험에 의한 내진 성능 평가 (Seismic Performance Evaluation of RC Bridge Piers with Limited Ductility by the Pseudo-Dynamic Test)

  • 정영수;박창규;박진영
    • 콘크리트학회논문집
    • /
    • 제15권5호
    • /
    • pp.705-714
    • /
    • 2003
  • 우리나라는 선진 외국에 비하여 늦은 1992년에 도로교 표준시방에 내진설계편이 도입되었다. 따라서, 1992년 이전에 설계된 교각들은 내진 설계가 되어있지 않음은 물론 시공편의상 소성힌지 구간에 주철근이 겹침이음 시공되어 현재에도 사용되고 있다. 또한, 현행 내진규정도 강진지역의 설계규정을 도입함으로써 중 약진 지역에 속하는 우리의 현실에 맞지 않아 현장에서 복잡한 철근배근을 요구함으로 시공성 및 경제성이 많이 떨어지고 있는 실정이다. 본 연구에서는 1992년 이전에 비내진 설계/시공되어 공용중인 원형 교각을 조사하여, 주철근이 겹침이음된 기준실험체(주철근비 1.01%, 심부구속철근비 0.13%) 1개를 실물크기와 유사하도록 직경 1.2m, 높이 4.8m로 제작하였으며, 또한 중 약진 지역에 속하는 우리나라의 실정을 감안하여 심부구속철근비를 비내진 규정의의 2.3배 현행 내진 설계규정의 0.32배에 해당하는 0.30%의 한정연성실험체 3개를 제작하여 유사동적 실험을 통하여 내진 연성도 평가를 하였다. 실험결과 비내진 실험체는 요구변위연성도 5를 만족시키지 못하였고, 한정연성 실험체의 경우는 현행 내진규정의 요구 변위연성도 5를 만족하는 것으로 나타났다.