• Title/Summary/Keyword: High-Assurance

Search Result 384, Processing Time 0.027 seconds

Exploration of the Multiple Structure of Relational Self and Construct Validation among Korean Adults (한국남녀의 관계적 자아의 특성: 다원적 구성요인 탐색 및 타당성 분석)

  • Ji Kyung Kim;Myoung So Kim
    • Korean Journal of Culture and Social Issue
    • /
    • v.9 no.2
    • /
    • pp.41-59
    • /
    • 2003
  • The present study was conducted to (1) explore the perceptions of Korean men and women about what is an important relationship for them and how do each gender group construe relational self, and (2) develop the scale to assess the factors of relational self and verify construct validity of the scale. 40 college students and 60 adults participated in survey and FGI (Focused Group Interview) respectively, and content analysis of their responses yielded 2 categories with 39 characteristics of relational self. The one category was named 'instrumentality' which was important to men and the other was named 'expressivity' which was important to women. The list of 39 items was administered to a nationwide sample of 1503 Korean adults to assess their construal of relational self through the 6-point Likert scale. Principal axis factor analysis showed that the two categories were unidimensional with high reliability. As a result of factor analysis on each category, a total of 9 factors were extracted. Specifically, the instrumentality consisted of factors such as utilitarianism, independence, initiativeness, self-assurance, and competence. And the factors of expressivity were empathy, passiveness, dependency, consideration. The tests of mean difference revealed that men had higher scores in most of the instrumental factors, while women had higher scores in most of the expressive factors. But there was no sex difference in the interdependent self-construal scale(Cross, 2000) which has been frequently used for measuring relational self. This is related to the Korean's collective cultural characteristics, and it was concluded that the relationship with others is very important to both Korean men and women, but the meaning and expectation of the relationship as well as the method for its preservation are different to each sex group. In addition, the correlation analyses indicated that the feminity score was positively correlated with the expressiveness while the masculinity score was positively correlated with instrumentality. This result implicated the differences of relational self among Korean people were related to the socialization process of each sex, i.e., sex role identity. Finally, limitations of this study and the directions for future research were discussed.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Effects of On-farm Management System on the Carcass Quality of Market Pigs (양돈장 관리시스템이 출하돈의 도체품질에 미치는 영향)

  • Kim, D.H.;Seo, J.T.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.1
    • /
    • pp.37-50
    • /
    • 2009
  • The purpose of this study was to investigate the effects of on-farm management systems(including the farm size, stocking density of growing-finishing phase, proportion of finisher diet and type of growing-finishing building) and pre-slaughter handling(including the transportation time and loading time) on carcass grade, the incidence of PSE pork, the meat quality score for intra-muscle fat, inter-muscle fat, subcutaneous fat and score for elasticity of market pigs. For this study, 248,787 pigs of 53 different farms were used to establish the pork quality assurance program and to meet the comsumer's need. The results are summarized as follows. 1. The farm size had significant influence on carcass grade, in which showing the higher grade by increasing the farm size. However, the incidence of PSE pork were not significantly differences among the farm size. The meat quality score for intra-muscle fat, inter-muscle fat, subcutaneous fat and score for elasticity of market pigs were not significant influenced by farm size. 2. The stocking density of growing-finishing phase was statistically significant for carcass grade, in which showing the higher grade in mid density group. However, the incidence of PSE pork was higher in high density group. The meat quality score for intra-muscle fat, inter-muscle fat and elasticity of market pigs were greater in mid density groups, but not influenced by stocking density for subcutaneous fat score. 3. The carcass grade and the incidence of PSE pork were not significantly influenced by transportation time. However, transportation time significantly affected the meat quality score, the meat quality score for intra-muscle fat, inter-muscle fat, subcutaneous fat and elasticity of the carcasses were superior in more than 1 hour transportation groups. 4. At any time loading, the carcass grade and PSE incidence were not significantly differences. However, the meat quality score for intra-muscle fat, inter-muscle fat and elasticity of market pigs were superior in before 10 AM groups, but not influenced by loading time for subcutaneous fat score. 5. The proportion of finisher diet had not significant influence on carcass grade, but PSE incidence affected by proportion of finisher diet, 21 percent or more group was higher PSE incidence. The meat quality score for intra-muscle fat and inter-muscle fat of the carcasses were superior in 21 percent or more fed finisher diet groups, but elasticity score of carcass had not influenced by the proportion of finisher diet. 6. The type of growing-finishing building was affected the carcass grade and PSE incidence of the market pigs, carcass grade and PSE incidence were superior in enclosed mechanical ventilation building groups. The meat quality score for intra-muscle fat and inter-muscle fat of the carcasses were not significantly differences by the type of finishing building, but the score of subcutaneous fat and elasticity of carcass were superior in opened natural ventilation building groups. In conclusion, the results of this study suggest that we have more precise on-farm management practice and the knowledge related to pre-slaughter handling skills to reduce the stress and improve the status of welfare of market pigs.

  • PDF

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF