A Study on the Air Pressure Endurance Test Device for High Speed Train Windows (고속철도차량 객차창문의 공기압력내구성 시험장치 개발에 관한 연구)

  • Chang, Dae-Sung;Yi, Won
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.2
    • /
    • pp.104-108
    • /
    • 2012
  • All of the Korean high speed train windows have been imported from abroad up to now. In this paper, the air pressure endurance test device for high speed train windows was studied and developed. This test device can create air pressure variation similar to train running real condition and carry out pressure endurance test according to international standard. Henceforward, this test device will be useful for domestic production of high speed train windows.

Development of Multiple-Windows Manager using virtual Screen (가상 화면을 이용한 다중 윈도우즈 매니저 개발)

  • Won, Hui-Chul;Choi, Jae-Kyung;Kim, Soon-Cheol
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.53-59
    • /
    • 2009
  • In this paper, we describe the problems which can happen during multi-tasking process in the Windows operating system (OS) environment. To cope with the problems, multiple-windows manager program is proposed in this paper. If we use the proposed multiple-windows manager program with three virtual screen, we can obtain the effect like using four Windows OS and thus we can improve the tardy speed and the high complexity for multi-tasking process.

Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building (노후 학교건물의 창호 교체에 따른 부하분석)

  • Lee, Ye Ji;Kim, Joo Wook;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

A Comparative strudy on the Insulation Performance of the Super Window by Actual Survey and Simulation (초단열 슈퍼윈도우의 단열성능 실측과 시뮬레이션 비교 분석)

  • Kim, Chi-Hoon;Ahn, Byung-Lip;Jang, Cheol-Yong;Hong, Won-Hwa
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.231-235
    • /
    • 2009
  • According to flow of energy, the loss occurs through walls, roofs, windows and so on. Among these case, most of the loss that is about 45% occurs through windows. windows's U-value is six times higher than wall's one according to Building code, so the loss through windows accounts for very much rates. Currently, Exterior wall's U-value about building envelope is 0.35~0.58W/ mK, but windows's one is 3.3W/ mK. It means that the loss through windows occupy very much amounts relatively. Therefore, the solution is required to reduce energy loss and increasing displeasure caused by excessive influx of solar energy through windows, to solve the problems Like decoloration on indoor furniture an clothes by harmful ultraviolet rays, air conditioning and increased cost. Therefore, on this paper, Thermal Performance was evaluated through actual test about high insulation Super Window which can improve thermal performance and the Simulation result was compared with actual resul by using Simulation program WINDOW and THERM.

  • PDF

A design and implementation of high-performance 2D PE architecture in H.264 Motion Estimation (H.264 움직임 추정의 고속 2D PE 아키텍쳐 설계 및 구현)

  • Lee, Kyung-Ho;Kong, Jin-Hyeung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.405-406
    • /
    • 2008
  • This paper presents a high performance 2D PE architecture for H.264 Motion Estimation(ME). While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new architecture scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows in 4 way(up,down,left,right). By reducing the redundant access factor by 1.4, the new 4-way search window improve the memory bandwidth by 70-58% compared with 1/3-way search window. With Altera Stratix-III implementation, the high performance 2D PE architecture deals with SD ($720{\times}480$) video of 2 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 97.1MHz.

  • PDF

A Study on the Enhancement of the Sound Insulation Performance of Windows through the Laboratory Tests (실험실 실험을 통한 창의 차음성능 개선에 관한 연구)

  • Kim, Sun-Woo;Chung, Jin-Yun;Lee, Ok-Kyun;Jang, Hyun-Choong;Park, Hyeon-Ku;Song, Hyuk
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.307-314
    • /
    • 2001
  • This study aims to provide fundamental data for enhancing the sound insulation performance of windows. For this study, windows composed of various types and thicknesses, were classified into five categories; fixed, single, double, triple and airtight, and then tested. In order to analyze their sound insulation characteristics and performances. test results were rated using methods such as D, STC, Ts and arithmetical mean. It was found that the sound insulation performance of windows is affected due to their type rather than the thickness of the glass. It was also found that when gap between the inner and outer frames was filled with caulking material, the sound transmission loss at high frequency bands was greatly improved. Therefore, the sound insulation performance of windows would be enhanced by minimizing the gap between frames.

  • PDF

Performance Comparison and Analysis of Container-based Host Operating Systems for sending and receiving High-capacity data on Server Systems

  • Kim, Sungho;Kwon, Oeon;Kim, Jung Han;Byeon, JiHyeon;Hwang, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.7
    • /
    • pp.65-73
    • /
    • 2022
  • Recently, as the Windows system supports the Windows subsystem for Linux (WSL), various researchers have studied to apply a docker container on various systems such as server systems, workstation system and so on. However, in various existing researchers, there is a lack of performance-related indicators to apply the system to each operating system (linux system and windows system). In this paper, we compared a performance comparison and analysis of container-based host operating systems. We configured experimental environments of operating systems for microsoft windows systems and linux systems based on a docker container support. In experimental results, the containers of linux systems reduced the average data latency of dataset 1-6 by 3.9%, 62.16%, 1552.38%, 7.27%, 60.83%, and 1567.2%, compared to the containers on microsoft windows systems.

Transparent Ceramics for Visible/IR Windows: Processing, Materials and Characterization

  • Jung, Wook Ki;Ma, Ho Jin;Kim, Ha-Neul;Kim, Do Kyung
    • Korean Journal of Materials Research
    • /
    • v.28 no.10
    • /
    • pp.551-563
    • /
    • 2018
  • Visible and IR windows require a combination of high optical transparency and superior thermal and mechanical properties. Materials, fabrication and characterization of transparent ceramics for visible/IR windows are discussed in this review. The transparent polycrystalline $Y_2O_3$, $Y_2O_3-MgO$ nanocomposites and $MgAl_2O_4$ spinel ceramics are fabricated by advanced ceramic processing and the use of special sintering technologies. Ceramic processing conditions for achieveing fully densified transparent ceramics are strongly dependent on the initial powder characteristics. In addition, appropriate use of sintering technologies, including vacuum sintering, hot-pressing and spark plasama sintering methods, results in outstanding thermal and mechanical properties as well as high optical transparency of the final products. Specifically, the elimination of light scattering factors, including residual pores, second phases and grain boundaries, is a key technique for improving the characteristics of the transparent ceramics. This paper discusses the current research issues related to synthesis methods and sintering processes for yttria-based transparent ceramics and $MgAl_2O_4$ spinel.

A Windows Operating System based Control Display Unit for a Commercial High Precision Inertial Navigation System (상용 초정밀 관성항법시스템용 윈도우즈 운영체제 기반 CDU(Control Display Unit) 설계)

  • Kim, Jeong-Won;Shin, Dae-Sik;Hwang, Dong-Hwang;Lee, Sang-Jeong;Park, Yong-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.101-103
    • /
    • 2005
  • This paper designs a CDU(Control Disaply Unit) for commercial high precision INS(Inertial Navigation System). The CDU is designed using GUI(Graphic User Interface) programming running on Windows operating system. Since the designed CDU provides standard functions of the Windows operating systems and has a modular structure, it is easy to modify and extend. The CDU has been interfaced to the H-726 INS, from which it's usefulness can be seen.

  • PDF

Implementation and performance evaluationof the XTP(xpress transport protocol) for multicasting in high-speed netorks (고속망에서의 멀티캐스트를 위한 고속 수송 프로토콜(XTP)의 구현 및 성능 평가)

  • 이경호;이완직;이선우;김철우;김정삼;장성식;한기준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.9
    • /
    • pp.2415-2421
    • /
    • 1996
  • This paper describes implementation and performance evaluation of XTP(Xpress Transport Protocol) onthe Windows NT for multicasting in high-speed communication networks. We designed the protocol byan event-driven method and implemented it in form of network driver in a kernel for performace enhancement. Various applications program are used for its functional test and comparison with the TCP protocol.

  • PDF