• Title/Summary/Keyword: High voltage pulse generator

Search Result 149, Processing Time 0.038 seconds

High Voltage Pulse Generator Using Power Semiconductor Switcher (전력용 반도체 소자를 이용한 새로운 고전압 펄스발생회로)

  • Baek, Ju-Won;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.8
    • /
    • pp.408-415
    • /
    • 2001
  • Using power semiconductor switches such as IGBTs, diodes and L-C circuits, novel repetitive impulse voltage generator is developed. In the presented circuits, high voltage pulse is generated by series-connection of capacitors and IGBTs. Therefore, the high voltage pulse is obtained by circuit configuration without any high voltage pulse transformer and high voltage dc source. Especially, the proposed circuit can operate up to several kHz and have high reliability and longer life than conventional ones. In also gives voltage balance of IBGTs automatically. So, the difference of characteristics of IGBTs and drive signal does not cause severe problems. To verify the proposed circuit, 20kV and 300A pulse generator is manufactured and tested.

  • PDF

Simulation Study of Characteristics for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 특성에 관한 시뮬레이션 연구)

  • Kim, Young-Ju;Shin, Ju-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.80-86
    • /
    • 2012
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows the high-voltage pulse generator simulation using a circuit program with experiment data. In the equivalent circuit, magnetized inductances and loss resistances which affect output voltage, have been obtained. The output capacitor circuits have characteristics of band pass. The output voltages of the pulse width 50% and 25%(PWM) were obtained. The output of the high-voltage pulse generator is 2.5kHz, 1.8kV.

Development of PC based High Voltage Generator for Dental CT (PC기반 치과 CT용 고전압 펄스 발생장치 개발)

  • Kim, Hack-Seong;Oh, Jun-Yong;Song, Sang-Hoon;Won, Choong-Yeon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

A High Voltage Pulse Generator Using a Rotatary Airhole Spark Gap Code (회전 공극형 고전압 펄스발생장치)

  • 문재덕;이종훈;이복희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.268-272
    • /
    • 2004
  • A high voltage pulse generator with a rotator airhole spark gap instead of a rotary ball spark gap has been proposed and investigated. Its feasibility as a high voltage pulse generator is compared with the rotary ball spark gap type one. Parametric studies showed that proposed the rotary airhole type spark gap had a very stable breakdown voltage and reliable pulse repetition time compared with the conventional rotary ball type spark gap. This however showed that the proposed pulse generator with a rotary airhole spark gap instead of a rotary ball spark gap could be potentially used as a very stable and reliable pulse generator in the various fields of applications.

Analysis of Output Pulse of High Voltage and Nanosecond Blumlein Pulse Generator

  • Roh, Young-Su;Jin, Yun-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.150-155
    • /
    • 2013
  • A high voltage and nanosecond Blumlein pulse generator has been developed to produce an output pulse whose voltage level is greater than 250 kV and pulse duration 5 ns. The generator consists of various components such as a charging circuit, a pulse transformer, and a spark gap switch. As a heart of the generator, a Blumlein pulse forming line has been constructed in the cylindrical form using three cylindrical aluminum electrodes that are placed concentrically. Unlike the ideal Blumlein line, the output pulse of an actual Blumlein line may be affected by stray inductances and capacitances of switching and charging components, thereby degrading the performance of the generator. In this paper, PSPICE simulations have been performed to examine effects of stray inductances and capacitances on waveforms of output pulses. Simulation results show that the pulse waveform is significantly distorted mainly by the stray inductance of the spark gap switch.

A Study on Optimization of Compact High-voltage Generator Based on Magnetic-core Tesla Transformer

  • Jeong, Young-Kyung;Youn, Dong-Gi;Lee, Moon-Qee
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1349-1354
    • /
    • 2014
  • This paper presents a compact and portable high-voltage generator based on magnetic-core Tesla transformer for driving an UWB high power electromagnetic source. In order to optimize the performance of the high-voltage generator, a novel open-loop cylindrical magnetic-core adopting the quad-division lamination structure is proposed and manufactured. The designed high-voltage generator using the proposed magnetic core has a battery-powered operation and compact size of $280mm{\times}150mm$ in length and diameter, respectively. The high-voltage generator can produce a voltage pulse waveform with peak amplitude of 450 kV, a rise time of 1.5 ns, and pulse duration of 2.5 ns at the 800 V input voltage.

Theoretical Study of Pulse Circuits with the Load Variation for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 관한 부하의 변화를 고려한 펄스회로의 이론적 연구)

  • Kim, Young-Ju;Bang, Sang-Seok;Lee, Chae-Han;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.3
    • /
    • pp.106-112
    • /
    • 2016
  • The high-voltage pulse generator consists of transformers of fundamental wave and harmonic waves, and shunt capacitors. The pulse has the fundamental wave and the harmonic waves that have been as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed by using transformer equivalent circuits with the effect of load and simulated in time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 2.0kV. In high voltage circuit, capacitors are related to frequency band pass characteristics. Also, it is shown that the voltage of output pulse increases according to the growth of load.

A New High-Voltage Generator for the Semiconductor Chip

  • Kim Phil Jung;Ku Dae Sung;Chat Sin Young;Jeong Lae Seong;Yang Dong Hyun;Kim Jong Bin
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.612-615
    • /
    • 2004
  • A high-voltage generator is used to program the anti-fuse of the semiconductor chip. A new high-voltage generator consists of PN diodes and new stack type capacitors. An oscillator supply pulses to the high-voltage generator. The pulse period of the oscillator is delayed by controlling gate-voltage of the MOS. The pulse period is about 27ns, therefore the pulse frequency is about 37MHz. The threshold voltage of PN diode is about 0.8V. The capacitance of new stack type capacitor is about 4pF. The output voltage of the new high-voltage generator is about 7.9V and its current capacity is about $488{\mu}$A.

  • PDF

Theoretical Study of the Circuits for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 회로에 관한 이론적 연구)

  • Kim, Young-Ju
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.99-108
    • /
    • 2013
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows that pulse generator circuit is analyzed using Miller's theorem and network theory(ABCD Matrix) and simulated in frequency and time domain using Matlab program. The output voltage of pulse were obtained to 2.5kHz, 1.8kV. Output pulse voltage increases as $L_m$ increases in low voltage circuit. In high voltage circuit, outer capacitors are related to frequency band pass characteristics.

A Damped Sinusoidal Electromagnetic Pulse Generator using a Charged Line (충전선로를 이용한 Damped Sinusoidal 전자기펄스 발생장치)

  • Ryu, Ji-Heon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.136-142
    • /
    • 2006
  • A damped sinusoidal electromagnetic pulse generator was designed, fabricated and tested. The pulse generator consisted of an oscillator(a spark gap switch and an initially charged low impedance line) and a high impedance antenna. This generator was capable of producing damped sinusoidal pulses at closure of the spark gap switch. A Marx generator was employed to supply the Pulse generator with high voltage pulses. While the pulse generator was provided with the high voltage pulses of 200kV from the Marx generator, its output power was maximized by controlling the pressure of the gas contained in the spark gap switch. The output power of the damped sinusoidal electromagnetic pulse oscillator was 1.3GW and the amplitude of electric field radiated from the pulse generator was 4kV/m at the range of 25m.