• 제목/요약/키워드: High voltage impulse

검색결과 192건 처리시간 0.032초

포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발 (Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell)

  • 홍진영;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

뇌충격 측정시스템의 비교시험에 의한 성능평가 - 전파 뇌충격전압 인가시 - (Performance Evaluations of the Lightning Impulse Voltage Measuring System by Intercomparative Test - in case of full lightning impulse voltage -)

  • 김익수;김영배;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1368-1370
    • /
    • 1995
  • Lightning impulse voltage is essential to evaluate the insulation performance of electric power apparatus. Recently international standard(IEC-60) on high voltage measurement techniques are being revised. In the draft of this standard, a new calibration method is introduced and the accuracy of most industrial measuring systems is maintained by means of comparison test against the reference measuring systems. Intercomparison tests of dividers for lightning impulse measurement were carried out by KERI. The shielded resisitive divider with 700kV rating developed by KERI were done comparison test with PTB divider with 300kV rating which have the similar charateristics as that were circulated among the laboratories. This paper reports on the comparison test results with full lightning impulse voltages from 126kV to 240kV. It is demonstrated that KERI are capable of realizing the idea in the revision of the IEC standand, that is, to establish traceability.

  • PDF

고전압 전력기기 개발을 위한 기중 임펄스절연파괴특성에 관한 연구 (Experimental study on the lightning impulse breakdown characteristics of air for the development of air-insulated high voltage apparatuses)

  • 강형구;김준연;석복렬;김동해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1473_1474
    • /
    • 2009
  • To develop electrically reliable high voltage apparatuses, the experimental study on the electrical breakdown field strength is needed, as well as theoretical approach. In this paper, lightning impulse breakdown characteristics considering utilization factors are investigated for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using five kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only gap length but also utilization factor of electrode systems. The results are expected to be applicable to the design of high voltage apparatuses.

  • PDF

임펄스전압에 의한 반구형 전극계에서 토양의 이온화 현상 (Soil Ionization Phenomena around a Hemispherical Electrode Stressed by Impulse Voltages)

  • 허대민;김회구;이복희
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.601-608
    • /
    • 2016
  • 접지전극이 매설되는 토양의 전기적 특성은 지역, 계절, 환경적 요인에 따라 저항률이 다양하게 변화한다. 접지전극 주변에서의 전기적 방전현상은 매우 다르게 발생하고, 이는 접지의 성능에 큰 영향을 미친다. 접지시스템의 설계 시에 다양한 조건에서 토양의 방전 특성과 이온화 현상에 관한 분석이 필요하다. 본 연구의 목적은 토양의 이온화 현상과 과도접지임피던스의 상관관계를 파악하는데 있다. 본 논문에서는 뇌임펄스전압에 의해 접지극 주변에서 발생하는 토양의 이온화 작용과 관련된 파라미터와 과도적인 접지저항에 관한 실험적 연구결과를 기술하였다.

고전압 임펄스를 활용한 발전용수 칼슘농도 저감에 관한 연구 (A Study on Calcium Ion Reduction in Power Plant Water using High Voltage Impulse)

  • 김태희;장인성;정재환;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.545-550
    • /
    • 2017
  • As an alternate technique for water softening, high voltage impulse (HVI) is introduced and verified if it can control the $CaCO_3$ scale formation in industrial water treatment. After HVI was applied to the artificial hard water containing $100{\pm}5mg/L$ $Ca^{2+}$ for 4 hours, the $Ca^{2+}$ concentration and the electrical conductivity were measured. The concentration of $Ca^{2+}$ was reduced from 94.5 to 86.3 mg/L (8.7% reduction) after 4 hour contact of HVI under 5 kV condition. The $Ca^{2+}$ was decreased from 92 to 77.7 mg/L (15.6% reduction) at 8kV and from 90.1 to 75.4 mg/L (16.3% reduction) at 12 kV condition. Both of the contact time and the applied voltage were important parameters affecting the calcium ion reduction. With these results, it was verified that HVI technique could be potential candidate for control of $CaCO_3$ scale formation.

고전압 임펄스 기술을 활용한 슬러지 가용화 (Solubilization of wasted sludge using high voltage impulse technique)

  • 조승연;장인성
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.257-262
    • /
    • 2017
  • Several disposal processes for waste sludge from wastewater treatment plants such as landfill, ocean dump, incineration, reuse as fuels or fertilizers are practiced. However, ocean dumping is prohibited by international treat. New constructions of landfill sites or incineration facilities are limited by NIMBY and reuse processes are still suffering from low energy yield. Therefore, development of alternative processes for sludge disposal are currently needed. In this study, alternative technique for sludge solubilization using HVI (high voltage impulse) was suggested and verified experimentally. Sludge solubilization was carried out for 90 minutes using HVI discharge with peak voltage of 16 kV and pulse duration for 40 microsecond. About 3~9 % of MLSS and MLVSS concentration were reduced, but the soluble COD, TN, TP of the sludge increased to 372 %, 56 % and 102 % respectively. It indicates that the flocs and/or cells of the sludge were damaged by HVI. These resulted in flocs-disintegration and cells-lysis, which means the internal matters were bursted out of the flocs as well as the cells. Thus, electrical conductivity in bulk solution was increased. All of the results verified that the HVI could be used as an alternative technique for sludge solubilization processes.

충격전압용 쉴드 저항형 분압기의 특성연구 (A study on the characteristics of shielded resistor divider for impulse voltage)

  • 김익수;김영배;문인욱;서길수;최재구;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1773-1775
    • /
    • 1997
  • The accuracy of impulse voltage measurement has been discussed and revised the IEC Publication 60-2 "High-voltage test techniques Part 2: Measuring Systems". Along with those activity, reference measuring systems have been experimentally investigated on their characteristics by step response method for lightning impulse voltage in our country. In this paper, using EMTP, we enable to clarify dominant factors affecting the unit step response, and to evaluate the construction of measuring system.

  • PDF

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

Electrical characteristics of insulating materials for HTS bushing immersed in $LN_2$

  • Choi, J.H.;Kim, W.J.;Shin, H.S.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.10-13
    • /
    • 2011
  • For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. In this paper, the surface flashover characteristics of various insulating materials in $LN_2$ are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The negative impulse breakdown voltage of GFRP is slightly higher than the positive impulse breakdown voltage. The use of glass fiber reinforced plastic (GFRP) and polytetrafluoroethylene (PTFE, Teflon) as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in $LN_2$ and operation of superconducting equipment.

154 kV급 HTS 케이블의 절연설계 및 굴곡시험 (Design of Insulation and Bending Test for a 154 kV Class HTS Cable)

  • 최진욱;최재형;임응춘;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1024-1028
    • /
    • 2008
  • It is important that study on cryogenic electrical insulation design to develop the cold dielectric(CD) type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. This paper proposes two types of insulation design to carry out the maximum insulation design for 154 kV-class HT cable. The proposed insulation design method takes into consideration AC and lightning impulse withstand voltage so as to prevent AC breakdown for power frequency operating voltage during operating the cable and breakdown for lightning impulse voltage. The final insulation thickness is determined by selecting high value out of two insulation thickness calculated through the two insulation design methods. And we researched electrical insulation characteristics of HTS cable according to bending ratio and the number of bending.