Design of Insulation and Bending Test for a 154 kV Class HTS Cable

154 kV급 HTS 케이블의 절연설계 및 굴곡시험

  • 최진욱 (경상대학교 전기공학과) ;
  • 최재형 (경상대학교 전기공학과) ;
  • 임응춘 (오산대학교 전기공학과) ;
  • 김해종 (한국전기연구원 초전도기기연구그룹) ;
  • 조전욱 (한국전기연구원 초전도기기연구그룹) ;
  • 김상현 (경상대학교 전기공학과)
  • Published : 2008.11.01

Abstract

It is important that study on cryogenic electrical insulation design to develop the cold dielectric(CD) type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. This paper proposes two types of insulation design to carry out the maximum insulation design for 154 kV-class HT cable. The proposed insulation design method takes into consideration AC and lightning impulse withstand voltage so as to prevent AC breakdown for power frequency operating voltage during operating the cable and breakdown for lightning impulse voltage. The final insulation thickness is determined by selecting high value out of two insulation thickness calculated through the two insulation design methods. And we researched electrical insulation characteristics of HTS cable according to bending ratio and the number of bending.

Keywords

References

  1. H. J. Kim, D. S. Kwag, S. H. Kim, J. W. Cho, and K. C. Seong, "Electrical insulation design and experimental results of a high-temperature superconducting cable", IEEE Trans. Appl. Supercond., Vol. 17, No. 2, p. 1743, 2007 https://doi.org/10.1109/TASC.2007.898493
  2. 김영석, 곽동순, 한철수, 김해종, 김동욱, 김상현, "Mini-model 초전도 케이블의 유전손실 특성", 전기전자재료학회논문지, 16권, 10호, p. 946, 2003
  3. D. S. Kwag, H. G. Choen, J. H. Choi, H. J. Kim, J. W. Cho, and S. H. Kim, "Electrical insulation design of a 154 kV class HTS cable and termination", Journal of the Korea Institute of Applied Superconductivity and Cryogenics, Vol. 9, No. 1, p. 61, 2007
  4. H. Suzuki, T. Takahashi, T. okamoto, and S. Akita, "Electrical insulation characteristics of cold dielectric high temperature super- conducting cable", IEEE Transaction on Dielectric and Electrical Insulation, Vol. 9, No. 6, p. 441, 2002
  5. J. W. Cho, H. J. Kim, K. C. Seong, H. M. Jang, D. W. Kim, and S. H. Kim, "Insulation test for the 22.9 kV class HTS power transmission cable", Journal of the Korea Institute of Applied Superconductivity and Cryogenics, Vol. 5, No. 3, p. 48, 2003
  6. 한국전력공사 송변전건설처 지중선팀, "154 kV 알루미늄피 유입케이블 및 부속재", 한전구매시방서, p. 10, 2002
  7. 곽동순, 천현권, 김해종, 조전욱, 정순용, 김상현, "고온초전도 케이블의 절연설계를 위한 적층효과", 전기전자재료학회논문지, 18권, 10호, p. 950, 2005 https://doi.org/10.4313/JKEM.2005.18.10.950