• Title/Summary/Keyword: High temperature tensile property

Search Result 139, Processing Time 0.028 seconds

Microstructure and Mechanical Property of Aluminum Powder Compact by Powder-in Sheath Rolling Method (분말시스압연법에 의해 제조된 알루미늄 분말성형체의 조직 및 기계적 성질)

  • 이성희
    • Journal of Powder Materials
    • /
    • v.9 no.3
    • /
    • pp.153-160
    • /
    • 2002
  • A nitrogen gas atomized aluminum powder was consolidated by powder-in sheath rolling method. A pure aluminum tube with outer diameter of 12 mm and wall thickness of 1mm was used as a sheath. The aluminum tube filled with the aluminum powder, first, was cold-rolled to the thickness of 6mm for performing, and then consolidated by the cold rolling and/or subsequent hot rolling at 360, 460 and $560^{\circ}C$. The aluminum powder compact fabricated by the sheath rolling showed high relative density more than 0.96 at any rolling conditions. The 0.2% proof stress increased with increasing hot rolling reduction and hot rolling temperature. Tensile strength was hardly affected by change in the hot rolling reduction, whereas it decreased with increasing hot rolling temperature. The powder compact showed the large elongation when cold rolling or hot rolling reduction was large. It was found that the sheath rolling was an effective method for consolidation of aluminum powder.

A Study on the Mechanical Properties of Structural Steels by Welding at High Temperature (용접한 건축구조용 강재의 고온 시 기계적 특성에 관한 연구)

  • Cho, Bum-Yean;Jee, NamYong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.161-164
    • /
    • 2009
  • This research is to show the mechanical properties of structural steels by welding at high temperature. Welding parts are divided with weld metal and HAZ(Heat Affected Zone). HAZ is formed by interval from welding heat source and heating and cooling rates. Then, the change of both microstructure and mechanical properties occurs. Discontinuity of mechanical and chemical property at HAZ is the cause of safety decrease of structure. At this point, in this research, tensile tests at high temperature with test pieces of base metal and weld metal of SS400 and SM490 are accomplished. From the results, the mechanical properties of both SS400 and SM490 are standardized without welding or non-welding.

  • PDF

Effect of Bonding Condition on High Temperature Mechanical Properties of TLP Bonded Joints of FE-35Ni-26Cr Alloy (Fe-35Ni-26Cr 주강 액상확산접합부의 고온기계적 특성에 미치는 접합조건의 영향)

  • 김대업
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.96-103
    • /
    • 2000
  • This study investigated the effects of bonding temperature and bonding atmosphere on high temperature mechanical properties of transient liquid phase(TLP) bonded joints of heat resistant alloy using MBF-50 insert metal. Specimens were bonded at 1,423~1,468K for 600s. Microconstituents of {TEX}$Cr_{7}(C,B)_{3}${/TEX}were formed in the bonded region when the bonding temperature was low. The amount of microcostituents in the bonded layer decreased with increasing the bonding temperature, and the microconstituents in the bonded layer disappeared at the bonding temperature above 1,468K. The tensile strength of the joints at elevated temperatures increased with the increase the bonding temperature and was the same level as one of the base metal in the bonding temperature over 1,453K. Microstructure and alloying element distributions of the bonded region bonded in Ar and $N_2$atmosphere were similar to those of the bonded in vacuum. The creep rupture strength and rupture lives of joints were almost identical to those of base metal.

  • PDF

Mechanical Property of Liquid Phase Diffusion Bonded Joint of Rene80/B/Rene80 (Rene 80/B/Rene 80 액상 확산접합부의 기계적 성질)

  • 정재필;강춘식
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.125-133
    • /
    • 1995
  • Rene80 superalloy was liquid phase diffusion bonded by using pure boron (B) as an insert material. As a basic study for the possibility of practical application of this bonding method, hardness and high temperature tensile strength of the bonded joint and metallurgical analysis were investigated. As experimental results, hardness of the bonded joint was homogenized after bonding and the tensile strength at 1144K was obtained to 90% of that of base metal. But there were some problems to be improved also, that means the joint was hardened after bonding due to increase of B content and elongation was much lower than that of base metal. Flat area and (Mo, Cr, W) boride, which should be harmful for bonding strength, were observed on the fractured surface of the tensile tested specimen.

  • PDF

Fatigue Strength Assessment of High Manganese Steel for LNG CCS (LNG CCS적용을 위한 고망간강의 극저온 피로성능 평가)

  • Lee, Jin-Sung;Kim, Kyung-Su;Kim, Yooil;Yu, Chang-Hyuk;Park, Jooil;Kang, Bong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.3
    • /
    • pp.246-253
    • /
    • 2014
  • Liquid natural gas is stored and transported inside cargo tank which is made of specially designed cryogenic materials such as 9% Ni steel, Al5083-O alloy and SUS304 and so on. The materials have to keep excellent ductile characteristics under the cryogenic environment, down to -163oC, in order to avoid the catastrophic sudden brittle fracture during the operation condition. High manganese steel is considered to be the promising alternative material that can replace the commonly used materials mentioned above owing to its cost effectiveness. In line with this industrial need, the mechanical properties of the high manganese steel under both room and cryogenic environment were investigated in this study focused on its tensile and fatigue behavior. In terms of the tensile strength, the ultimate tensile strength of the base material of the high manganese steel was comparable to the existing cryogenic materials, but it turned out to be undermatched one when welding is involved in. The fatigue strength of the high manganese steel under room temperature was as good as other cryogenic materials, but under cryogenic environment, slightly less than others though better than Al 5083-O alloy.

Plasticity and Fracture Behaviors of Marine Structural Steel, Part IV: Experimental Study on Mechanical Properties at Elevated Temperatures (조선 해양 구조물용 강재의 소성 및 파단 특성 IV: 고온 기계적 물성치에 관한 실험적 연구)

  • Choung, Joon-Mo;Im, Sung-Woo;Park, Ro-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.66-72
    • /
    • 2011
  • This is the fourth of a series of companion papers dealing with the mechanical property reductions of various marine structural steels. Even though a reduction of the elastic modulus according to temperature increases has not been obtained from experiments, high temperature experiments from room temperature to $900^{\circ}C$ revealed that initial the yield strength and tensile strength are both seriously degraded. The mechanical properties obtained from high temperature experiments are compared with those from EC3 (Eurocode 3). It is found that the high temperature test results generally comply with the prediction values by EC3. Based on the prediction of EC3, time domain nonlinear finite element analyses were carried out for a blast wall installed on a real FPSO. After applying the reduced mechanical properties, corresponding to $600^{\circ}C$ to the FE model of the blast wall, more than three times the deflections were observed and it was observed that most structural parts experience plastic deformations exceeding the reduced yield strength at the high temperature. It is noted that a protection facility such as PFP (passive fire protection) should be required for structures likely to be directly exposed to fire and explosion accident.

THE EFFECT OF HYDROGEN AND OXYGEN CONTENTS ON HYDRIDE REORIENTATIONS OF ZIRCONIUM ALLOY CLADDING TUBES

  • CHA, HYUN-JIN;JANG, KI-NAM;AN, JI-HYEONG;KIM, KYU-TAE
    • Nuclear Engineering and Technology
    • /
    • v.47 no.6
    • /
    • pp.746-755
    • /
    • 2015
  • To investigate the effect of hydrogen and oxygen contents on hydride reorientations during cool-down processes, zirconium-niobium cladding tube specimens were hydrogen-charged before some specimens were oxidized, resulting in 250 ppm and 500 ppm hydrogen-charged specimens containing no oxide and an oxide thickness of $0.38{\mu}m$ at each surface. The nonoxidized and oxidized hydrogen-charged specimens were heated up to $400^{\circ}C$ and then cooled down to room temperature at cooling rates of $0.3^{\circ}C/min$ and $8.0^{\circ}C/min$ under a tensile hoop stress of 150 MPa. The lower hydrogen contents and the slower cooling rate generated a larger fraction of radial hydrides, a longer radial hydride length, and a lower ultimate tensile strength and plastic elongation. In addition, the oxidized specimens generated a smaller fraction of radial hydrides and a lower ultimate tensile strength and plastic elongation than the nonoxidized specimens. This may be due to: a solubility difference between room temperature and $400^{\circ}C$; an oxygen-induced increase in hydrogen solubility and radial hydride nucleation energy; high temperature residence time during the cool-down; or undissolved circumferential hydrides at $400^{\circ}C$.

Analysis of Mechanical Property Changes of Polymer Eyeglass Frames by Thermal Impact (고분자 안경테의 온도에 의한 기계적 물성 변화 분석)

  • Seo, Hogeun;Yoon, Taeyang;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.429-434
    • /
    • 2014
  • Purpose: To analyze thermal effect on mechanical properties of domestic commercial polymer-based eyewear frames. Methods: In this study, materials of cellulose acetate, polyamide, epoxy, and polyetherimide were exposed to high or low temperature and were mounted on universal test machine (TO-100-IC) for tensile strength test. Elastic behavior, Young's modulus, maximum displacement, and fatigue were tested with various temperature ($-25^{\circ}C$, $25^{\circ}C$, $60^{\circ}C$). Results: As a result, at room temperature, displacements of materials were changed with increasing impact load. At low temperature ($-25^{\circ}C$), maximum displacements of all specimens were decreased but young's modulus were increased. However, at high temperature, maximum displacements of all specimens were increased but young's modulus were decreased. Conclusions: Degree of displacements due to fatigue behavior was increased following direction of PEI, epoxy, polyamide, acetate. We concluded that commercial polymers used in eyewear frames physical properties were changed differently to exposed temperature.

Microstructure and Mechanical Properties of Rapidly Solidified Powder Metallurgy Al-Fe-V-Si-X Alloys

  • Genkawa, Takuya;Yamasaki, Michiaki;Kawamura, Yoshihito
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1041-1042
    • /
    • 2006
  • High heat-resistant Al-Fe-V-Si and Al-Fe-V-Si-X rapidly solidified powder metallurgy (RS P/M) alloys have been developed under well-controlled high purity argon gas atmosphere. The $Al_{90.49}Fe_{6.45}V_{0.68}Si_{2.38}$ (at. %) RS P/M alloy exhibited high elevated-temperature strength exceeding 300 MPa and good ductility with elongation of 6 % at 573 K. Reduction of $H_2O$ partical pressure in P/M processing atmosphere led to improvement in mechanical properties of the powder-consolidated alloys under elevated-temperature service conditions. Ti addition to the Al-Fe-V-Si conduced to enhancement of the strength at room temperature. The tensile yeild strength and ultimate strenght were 545 MPa and 722 MPa, respectively.

  • PDF

A Study on the Welding Characteristics of Hastelloy C-276 using a Continuous Wave Nd:YAG Laser (연속파형 Nd:YAG 레이저를 이용한 Hastelloy C-276의 용접특성에 관한 연구)

  • Na, Gee-Dae;Yoo, Young-Tae;Shin, Ho-Jun;Oh, Yong-Seok
    • Journal of Welding and Joining
    • /
    • v.26 no.5
    • /
    • pp.49-59
    • /
    • 2008
  • Hastelloy C-276, corrosion resistant alloy at high temperature, is used in chemical plant and power generation industry. In this study, process parameter of laser welding for welding property in Hastelloy C-276 using a continuous wave Nd:YAG laser was studied. As the result of experiment, laser welding did not show segregation or crack at heat affected zone compared to conventional GTWA welding. The melting zone showed cell dendritic structure along with welding line. In addition, planer front solidification is occurred from welding structure, and it was progressed to cellular solidification. Optimal process parameter for butt welding was 1.2kW and 2.0 m/min for laser power and welding speed, respectively. While heat input, output density, tensile stress, and longitudinal strain was $441.98{\times}103$ J/cm2, $29.553{\times}103$ W/cm2, 768 MPa, and 0.689, respectively. Lap welding of the same material showed greater discrepancy in tensile property during 1 line and 2 line welding. For 1 line welding, tensile stress was about 320 MPa, and 2 line showed slightly larger tensile stress. However, strain was decreased by 20%. From this result, lap welding of the same material, Hastelloy C-276, with 2 line welding is considered to be more effective process than 1 line welding with consideration of mechanical property.