• Title/Summary/Keyword: High school building

Search Result 1,049, Processing Time 0.028 seconds

A Rainfall-runoff Analysis Method of SWMM Model Considering Building Height (건물 높이를 고려한 SWMM 모형의 강우-유출해석 방법 제안)

  • Lee, Hyoungtaek;Cho, Eunsaem;Yoo, Chulsang
    • Journal of Wetlands Research
    • /
    • v.20 no.1
    • /
    • pp.14-19
    • /
    • 2018
  • In this study, the method considering the influence of the high-rise building in urban rainfall-runoff analysis using SWMM was proposed. The method proposed in this study was to calculate the time of reaching the surface of the rainwater considering the size and height of the building, and to modify the basin width to reflect this. In the method proposed in this study, the concentration time considering the size and height of the building is calculated and based on this time the basin width is modified. The proposed method was verified with the experimental result of Isidoro et al. (2012). As a result, the proposed method was found to be valid since the simulated hydrograph was fairly identical to experimental result. In both hydrographs, it was confirmed that the change of the discharge characteristic, such as decrease of peak discharge and lag of peak time, over increasing density of the building was similar each other.

Shape Effects on Aerodynamic and Pedestrian-level Wind Characteristics and Optimization for Tall and Super-Tall Building Design

  • Kim, Yong Chul;Xu, Xiaoda;Yang, Qingshan;Tamura, Yukio
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.4
    • /
    • pp.235-253
    • /
    • 2019
  • This paper reviews shape optimization studies for tall and super-tall building design. Firstly, shape effects on aerodynamic and response characteristics are introduced and discussed. Effects of various configurations such as corner modifications, taper, setback, openings, and twists are examined. Comprehensive comparative studies on various configurations including polygon building models, and composite type building models such as corner-cut and taper, corner-cut and taper and helical, and so on, are also discussed under the conditions of the same height and volume. Aerodynamic characteristics are improved by increasing the twist angle of helical buildings and increasing the number of sides of polygon buildings, but a twist angle of $180^{\circ}$ and a number of sides of 5 (pentagon) seem to be enough. The majority of examined configurations show better aerodynamic characteristics than straight-square. In particular, composite type buildings and helical polygon buildings show significant improvement. Next, shape effects on pedestrian-level wind characteristics around tall and super-tall buildings are introduced and discussed. Corner modification buildings show significant reductions in speed-up areas. On the other hand, setback and tapered models with wider projected widths near the ground show adverse effects on pedestrian-level wind characteristics.

A Kalman filter based algorithm for wind load estimation on high-rise buildings

  • Zhi, Lun-hai;Yu, Pan;Tu, Jian-wei;Chen, Bo;Li, Yong-gui
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.449-459
    • /
    • 2017
  • High-rise buildings are generally sensitive to strong winds. The evaluation of wind loads for the structural design, structural health monitoring (SHM), and vibration control of high-rise buildings is of primary importance. Nevertheless, it is difficult or even infeasible to measure the wind loads on an existing building directly. In this regard, a new inverse method for evaluating wind loads on high-rise buildings is developed in this study based on a discrete-time Kalman filter. The unknown structural responses are identified in conjunction with the wind loads on the basis of limited structural response measurements. The algorithm is applicable for estimating wind loads using different types of wind-induced response. The performance of the method is comprehensively investigated based on wind tunnel testing results of two high-rise buildings with typical external shapes. The stability of the proposed algorithm is evaluated. Furthermore, the effects of crucial factors such as cross-section shapes of building, the wind-induced response type, errors of structural modal parameters, covariance matrix of noise, noise levels in the response measurements and number of vibration modes on the identification accuracy are examined through a detailed parametric study. The research outputs of the proposed study will provide valuable information to enhance our understanding of the effects of wind on high-rise buildings and improve codes of practice.

Analysis of Environment Improving Budget of School Facilities by Using Data Warehouse Technology - Focused on Elementary, Middle, High School of OO Office of Education - (데이터 웨어하우스 기술을 활용한 학교시설물의 환경개선예산 분석 - OO교육청 초·중·고등학교를 중심으로 -)

  • Pak, Min-Kyu;Son, Chang-Baek;Ryu, Han-Guk
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.13 no.1
    • /
    • pp.15-23
    • /
    • 2014
  • With introduction of amended educational curriculum in 2007, optimizing project of educational environment to accomplish its purposes and goals includes expanding educational facilities and supplying eco-friendly school facilities. However, while the focus of optimizing project of educational environment is quality improvement of educational facilities, aging of these facilities built at th times of quantitative expansion and its management become serious problems. Higher concerns on studies and jobs on management of building caused by serious aging of facilities, management cost of building becomes a very crucial issue. Therefore, this study aims to analyze environment improvement budget of school facilities through building and using data warehouse, by investigating and analyzing the current status of environment improvement budget of school facilities and its cost through questionnaire and interview surveys on officers who are in charge of environment improvement budget of school facilities in educational administrations. This study thus analyzed environment improving budget of school facilities by using data warehouse technology collecting related data to the topic and setting levels by region, school class, establishment year, school facility types and others.

Evaluation of the Impacts of Stack Effect in High-Rise Buildings

  • Yang, In-Ho;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.91-103
    • /
    • 2003
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impacts on the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal air flow resistance. Therefore the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

A study on Architectural Characters of well-designed middle and high school buildings in 2000's - On Winning Works of 'The Excellent Facility School Award' by Ministry of Education, Science and Technology - (2000년 이후 중.고등학교 시설의 건축 특성 연구 - 교육과학기술부 선정 '우수시설학교' 수상작을 중심으로 -)

  • Seong, Eun-Young;Yang, Sang-Hyun
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.1
    • /
    • pp.25-35
    • /
    • 2012
  • The function and the role of school are changing according to various future-oriented education models such as open-ended learning cycle, community learning center, re-schooling, network system and de-schooling, which reflect recent social demands related to discussions on sustainability, low birth rate and ageing. what changes to our school buildings have been there? This study is aimed that shows the architectural change of school buildings and environments in 2000's. It reveals the architectural tendancy through some school buildings, 'the excellent facility school award' winner which Ministry of Education, Science and Technology have chosen annually since 1998. In the past decade, it is outstanding change that mass composition, window patterns and exterior wall materials are diversified greatly. The most of them have a opened main hall and multi-purpose spaces which give effective educational environment to students. Although visual changes are outstanding, we still need qualitative educational space program and improved school building design according to future-educational demands.

Evaluation of Deterioration Grade for Remodeling Architectural Facilities in Old Schools (학교건물(學校建物) 건축설비(建築設備)시스템의 노후도(老朽度) 평가(評價) 기준(基準)마련을 위한 기초연구(基礎硏究))

  • Cho, Min-Kwan;Cho, Chang-Geun;Park, Jong-Soo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.4
    • /
    • pp.15-23
    • /
    • 2006
  • The purpose of this study is to establish the objective deterioration grades and evaluation criteria of building equipment system of educational facilities available for reasonable maintenance and remodeling of them. For the purpose of it, the actual conditions of building equipment systems of the 148 buildings of 84 middle and high schools in Seoul 20 years after construction are investigated and surveyed through one-on-one interviews and questionnaires. And, deterioration grades of them are estimated by the evaluation criteria which is proposed in this study. As a result of this study, the 10 deterioration grades and the 4 evaluation criteria of the 6 performances of building equipment system, which are heating and cooling, water supply and drainage, hot water supply and electrical power performance, are suggested. And, as a result of the survey, it showed that 24% of the investigated school buildings were estimated C grade which needs partial remodelling, and 51% of the school buildings were estimated D grade which needs extensive remodelling. And, 25% of the school buildings were estimated E grade which needs overall remodelling or alteration of building equipment system.

A Study on Problems and Improvement for G-SEED of Evaluation System through Investigating Transition Process of Overseas Green Building Certification Criterion - Focused on Apartment - (국내외 친환경 건축물 인증제도의 변천과정 고찰을 통한 G-SEED의 평가 체계 개선방안 연구 - 공동주택을 중심으로 -)

  • Park, Jae-Han;Cha, Gi-Wook;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.24 no.5
    • /
    • pp.69-76
    • /
    • 2013
  • The seriousness of greenhouse gas exhaustions and energy use of the building has increased, the world is making an effort with many requests and the consultation for sustainable development. For this reason, Green Building Certification Criteria has been implemented to reduce environmental load, high-performance and environmentally friendly in the United States, the United Kingdom and Germany. In response to the global trend like this, the Korean Government has induced the eco-friendly construction and sustainable development to implement the G-SEED (Green Building Certification Criteria of Korea) in 2002. However, in spite of the many authentication result, G-SEED has been pointed out that it needs for improve in the evaluation system of Apartment sector which accounts for more than 40% of the authentication. Therefore, the purpose of this study is to suggest improvements in the evaluation system. To achieve this, this study have selected for LEED, BREEAM, DGNB of comparison target, drawn improvements through comparing transition process in G-SEED.

A Study on the Privatization of School Facilities Maintenance (학교시설유지관리의 민간위탁에 관한 연구)

  • Cho, Chang-Hee;Lee, Hwa-Ryong
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.15 no.2
    • /
    • pp.39-49
    • /
    • 2008
  • School facilities maintenance is concerned about providing clean and safe environments for children. It is also about creating a physical setting that is appropriate and adequate for learning. But many of the school buildings in Korea have been maintained and operated by each school manger or pubic officers in the Educational Department. This system could not extend the life of building components, keep equipment functioning as designed or sustain a sage and healthful environment because of its non-professionality and the dual fiscal system. In order to improve such problems, it is proposed to privatize the maintenance of school building. It is sure that the new way to outsource services reduce costs and provide high quality services. Competitive contracting with the private sector can provide schools with expertise, flexibility and cost efficiencies as well as help school administrators focusing on educating the children. This study explores the maintaining status of existing schools, analyses the cases about BTL schools and the foreign country's policies and surveys the outsourcing cases of Kyungki-do schools. Finally it proposes more appropriate plans for privatizing the maintenance way of school building in Korea.

Correlation of damage and analysis of R/C building: Experience from the 1995 Kobe earthquake

  • Matsumori, Taizo;Otani, Shunsuke
    • Structural Engineering and Mechanics
    • /
    • v.6 no.8
    • /
    • pp.841-856
    • /
    • 1998
  • During the 1995 Hyogoken-Nanbu Earthquake, a reinforced concrete building, called Jeunesse Rokko, suffered intermediate damage by forming a beam-yielding (weak-beam strong-column) mechanism, which has been regarded as the most desirable earthquake resisting mechanism throughout the world. High cost to repair damage at many beam ends and poor appearance expected after the repair work made the owner decide to tear down the building. Nonlinear earthquake response analyses were conducted to simulate the behavior of the building during the earthquake. The influence of non-structural members was considered in the analysis. The calculated results were compared with the observed damage, especially the location of yield hinges and compression failure of spandrel beams, and the degree of cracking in columns and in column-girder connections.