• Title/Summary/Keyword: High power Signal

Search Result 1,831, Processing Time 0.03 seconds

Design of Power Plane for Suppressing Spurious Resonances in High Speed PCBs

  • Oh Seung-Seok;Kim Jung-Min;Yook Jong-Gwan
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.1
    • /
    • pp.62-70
    • /
    • 2006
  • This paper presents a new power plane design method incorporating a single geometry derived from a unit cell of photonic bandgap(PBG) structure. This method yields constantly wide suppression of parallel plate resonances from 0.9 GHz to 4.2 GHz and is very efficient to eliminate PCB resonances in a specified frequency region to provide effective suppression of simultaneous switching noise(SSN). It is shown that with only two cells the propagation of unwanted high frequency signals is effectively suppressed, while it could provide continuous return signal path. The measured results agree very well with theoretically predicted ones, and confirm that proposed method is effective for reducing EMI, with measured near-field distribution. The proposed topology is suitable for design of high speed digital system.

Mobile Positioning Without GPS in CDMA2000 1X

  • Eun-Tae Won;Su-ki Paik
    • Journal of Internet Computing and Services
    • /
    • v.2 no.5
    • /
    • pp.49-58
    • /
    • 2001
  • Mobile positioning measurement is the most important technology for Location Based Services in the cellular networks. Generally, we are expecting to use GPS to guarantee high accuracy of the mobile position, A CDMA network-based technique for the Mobile Station position calculation needs to be implemented in the cdma2000 network whether the handsets have GPS or not, The most reliable methods of the network-based location technologies are based on the estimation of time of signal traveling between MS and B18 in a network whose coordinates are identified, Other signal parameters such as the power of the received signal and the signal arrival direction cannot be used as main data for a location system because adoption of only the signal parameters will not meet the FCC requirements, In practice, the estimates of the time of signal propagation between MS and BTS always have errors resulting from low-resolution power of measurements and multi path signal propagation, This paper describes the combined network-based location technology in the cdma2000 1× necessary to meet US FCC requirements. The issues of a calibration table and statistic processing based on the pilot strength as well as combined network-based location technologies(TOA/ TDOA) will help to achieve higher location accuracy than specified in the US FCC Rule.

  • PDF

Handover Performance of LTE-R Networks (LTE-R 네트워크에서 핸드오버 성능)

  • Kim, Young-Dong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1223-1228
    • /
    • 2018
  • LTE-R(Long Term Evolution - Railway), as a mobile communication technology to support safety operation of train on high speed railway system, have to be equipped appropriately by hand-over method for high moving environment of train. In this paper, hand-over performance of LTE-R network, which is used in railway communication system, is analyzed and hand-over implementation condition is suggested with this analysis. The performance analysis of this study is carried out with computer simulation with NS(Network Simulator)-3. SINR(Signal to Interference and Noise Ratio) and RSRP(Reference Signal Received Power), and Data Rate is used for hand-over performance parameter.

Power Quality Signal Compression and Restoration based on Two Component (두 성분을 이용한 전력품질 신호의 압축 및 복구)

  • Chung, Young-Sik;Kim, Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.125-126
    • /
    • 2006
  • Data storage and data communication currently pose a major problems for all parties involved with power quality and power system monitoring. The Problem aries from the tremendous amount of data involved. There is a common desire in the power industry to find new techniques for high-accuracy data compression and data storage. This paper introduces a data compression technique that is very suitable for application to power quality waveforms. The proposed technique is applied in splitting the monitored signal into two components. Those are stationary and nonstationary components. Each component is compressed and encoded.

  • PDF

Study on Evaluation of the Leak Rate for Steam Valve in Power Plant (발전용 증기밸브 누설량 평가에 관한 연구)

  • Lee, S.G.;Park, J.H.;Yoo, G.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

Estimation Technique of Frequency using FIR Filter in the Power System (FIR 필터를 이용한 전력계통의 주파수 추정기법)

  • 남시복;박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.50 no.3
    • /
    • pp.101-108
    • /
    • 2001
  • Frequency is an important operating parameter of a power system. Electric power systems sustain transient frequency swings whenever the balance between generation and load does not no longer hold. To cope with this constraints, it requires an accurate and high speedy frequency deviation estimation technique and suitable adjustment to obtain the Power system energy balance. This paper describes a digital signal processing technique for measuring the operating frequency of a power system. The fundamental frequency component of 3-phase signal is first extracted by using an algorithm based on FIR filter. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154KV double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

A Modified Method Based on the Discrete Sliding Norm Transform to Reduce the PAPR in OFDM Systems

  • Salmanzadeh, R.;Mozaffari Tazehkand, B.
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.42-50
    • /
    • 2014
  • Orthogonal frequency division multiplexing (OFDM) is a modulation technique that allows the transmission of high data rates over wideband radio channels subject to frequency selective fading by dividing the data into several narrowband and flat fading channels. OFDM has high spectral efficiency and channel robustness. However, a major drawback of OFDM is that the peak-to-average power ratio (PAPR) of the transmitted signals is high, which causes nonlinear distortion in the received data and reduces the efficiency of the high power amplifier in the transmitter. The most straightforward method to solve this problem is to use a nonlinear mapping algorithm to transform the signal into a new signal that has a smaller PAPR. One of the latest nonlinear methods proposed to reduce the PAPR is the $L_2$-by-3 algorithm, which is based on the discrete sliding norm transform. In this paper, a new algorithm based on the $L_2$-by-3 method is proposed. The proposed method is very simple and has a low complexity analysis. Simulation results show that the proposed method performs better, has better power spectral density, and is less sensitive to the modulation type and number of subcarriers than $L_2$-by-3.

A Framework for Wide-area Monitoring of Tree-related High Impedance Faults in Medium-voltage Networks

  • Bahador, Nooshin;Matinfar, Hamid Reza;Namdari, Farhad
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Wide-area monitoring of tree-related high impedance fault (THIF) efficiently contributes to increase reliability of large-scaled network, since the failure to early location of them may results in critical lines tripping and consequently large blackouts. In the first place, this wide-area monitoring of THIF requires managing the placement of sensors across large power grid network according to THIF detection objective. For this purpose, current paper presents a framework in which sensors are distributed according to a predetermined risk map. The proposed risk map determines the possibility of THIF occurrence on every branch in a power network, based on electrical conductivity of trees and their positions to power lines which extracted from spectral data. The obtained possibility value can be considered as a weight coefficient assigned to each branch in sensor placement problem. The next step after sensors deployment is to on-line monitor based on moving data window. In this on-line process, the received data window is evaluated for obtaining a correlation between low frequency and high frequency components of signal. If obtained correlation follows a specified pattern, received signal is considered as a THIF. Thereafter, if several faulted section candidates are found by deployed sensors, the most likely location is chosen from the list of candidates based on predetermined THIF risk map.

A Highly Efficient Dual-Mode 3G/4G Linear CMOS Stacked-FET Power Amplifier Using Active-Bypass

  • Kim, Unha;Kim, Yong-Gwan;Woo, Jung-Lin;Park, Sunghwan;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.393-398
    • /
    • 2014
  • A highly efficient dual-mode linear CMOS stacked-FET power amplifier (PA) is implemented for 3G UMTS and 4G LTE handset applications. High efficiency is achieved at a backed-off output power ($P_{out}$) below 12 dBm by employing an active-bypass amplifier, which consumes very low quiescent current and has high load-impedance. The output paths between high- and low-power modes of the PA are effectively isolated by using a bypass switch, thus no RF performance degradation occurs at high-power mode operation. The fabricated 900 MHz CMOS PA using a silicon-on-insulator (SOI) CMOS process operates with an idle current of 5.5 mA and shows power-added efficiency (PAE) of 20.5%/43.5% at $P_{out}$ = 12.4 / 28.2 dBm while maintaining an adjacent channel leakage ratio (ACLR) better than -39 dBc, using the 3GPP uplink W-CDMA signal. The PA also exhibits PAE of 35.1% and $ACLR_{E-UTRA}$ of -33 dBc at $P_{out}$ = 26.5 dBm, using the 20 MHz bandwidth 16-QAM LTE signal.

Design and Implementation of the Basic Technology for Solitary Senior Citizen's Lonely Death Monitor ing System using PLC

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.6
    • /
    • pp.742-752
    • /
    • 2015
  • The communications through the power lines are called as the PLC and this is a common name for the communication modes for the information delivery. This technology transmits the data through the power lines on which the information is stored with the form of high frequency signal. The characteristic of the frequency signal is that the signal can be separated from the power line through exclusive power line modem and transmitted to the terminal devices. In this paper, 'In-home Headcount' checking algorithm using Wi-Fi and taking above mentioned advantages is proposed, and the basic Technology for such Solitary Senior Citizen's Lonely Death monitoring system has been designed and implemented. The comparative analysis has been conducted in this paper with the test-operated and test bed-completed 'Hyosimi 119 Safety-Welfare System' which is still being tested since 2008. With the 'In-home Headcount Checking Algorithm', Wi-Fi connection/disconnection status and SSIDs of relevant Wi-Fis will be checked. We expect that our proposed method will become as the basic Technology which can prevent lonely deaths of elderly people living alone. Since the PLC technology can be normally implement all the functions used on internet anticipate that the technology could be applied to many areas to construct a new form of communication network.